How to Calculate Design Strength of Axially Loaded Composite Column?
Design Strength of Axially Loaded Composite Column calculator uses Nominal Load = 0.85*Gross Area of Steel Core*Critical Compressive Stress/Resistance Factor to calculate the Nominal Load, The Design Strength of Axially Loaded Composite Column formula is defined as the load-bearing capacity of a member computed on the basis of the allowable stresses which are assumed in design. Nominal Load is denoted by Pn symbol.
How to calculate Design Strength of Axially Loaded Composite Column using this online calculator? To use this online calculator for Design Strength of Axially Loaded Composite Column, enter Gross Area of Steel Core (AGross), Critical Compressive Stress (Fcr) & Resistance Factor (Φ) and hit the calculate button. Here is how the Design Strength of Axially Loaded Composite Column calculation can be explained with given input values -> 3060 = 0.85*5.1E-05*60000000/0.85.