Decay of Current in LR circuit Solution

STEP 0: Pre-Calculation Summary
Formula Used
Decay of Current in L-R Circuit = Electric Current*e^(-Time Period of Progressive Wave/(Inductance/Resistance))
Idecay = ip*e^(-Tw/(L/R))
This formula uses 1 Constants, 5 Variables
Constants Used
e - Napier's constant Value Taken As 2.71828182845904523536028747135266249
Variables Used
Decay of Current in L-R Circuit - (Measured in Ampere) - Decay of Current in L-R Circuit is the rate at which the current in an L-R circuit is decaying.
Electric Current - (Measured in Ampere) - Electric Current is the time rate of flow of charge through a cross sectional area.
Time Period of Progressive Wave - (Measured in Second) - Time period of progressive wave is the time taken by a wave to complete one oscillation.
Inductance - (Measured in Henry) - Inductance is the tendency of an electric conductor to oppose a change in the electric current flowing through it.
Resistance - (Measured in Ohm) - Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
STEP 1: Convert Input(s) to Base Unit
Electric Current: 2.2 Ampere --> 2.2 Ampere No Conversion Required
Time Period of Progressive Wave: 2.6 Second --> 2.6 Second No Conversion Required
Inductance: 5.7 Henry --> 5.7 Henry No Conversion Required
Resistance: 10.1 Ohm --> 10.1 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Idecay = ip*e^(-Tw/(L/R)) --> 2.2*e^(-2.6/(5.7/10.1))
Evaluating ... ...
Idecay = 0.0219593956437619
STEP 3: Convert Result to Output's Unit
0.0219593956437619 Ampere --> No Conversion Required
FINAL ANSWER
0.0219593956437619 0.021959 Ampere <-- Decay of Current in L-R Circuit
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Dipto Mandal
Indian Institute of Information Technology (IIIT), Guwahati
Dipto Mandal has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Basics of Electromagentic Induction Calculators

EMF Induced in Rotating Coil
​ LaTeX ​ Go EMF Induced in a Rotating Coil = Number of Turns of Coil*Area of Loop*Magnetic Field*Angular Velocity*sin(Angular Velocity*Time)
Decay of Current in LR circuit
​ LaTeX ​ Go Decay of Current in L-R Circuit = Electric Current*e^(-Time Period of Progressive Wave/(Inductance/Resistance))
Current Value for Alternating Current
​ Go Electric Current = Peak Current*sin(Angular Frequency*Time+Phase Difference)
Capacitive Reactance
​ LaTeX ​ Go Capacitive Reactance = 1/(Angular Velocity*Capacitance)

Decay of Current in LR circuit Formula

​LaTeX ​Go
Decay of Current in L-R Circuit = Electric Current*e^(-Time Period of Progressive Wave/(Inductance/Resistance))
Idecay = ip*e^(-Tw/(L/R))

What is L-R circuit?

A resistor–inductor circuit, or RL filter or RL network, is an electric circuit composed of resistors and inductors driven by a voltage or current source.

How to Calculate Decay of Current in LR circuit?

Decay of Current in LR circuit calculator uses Decay of Current in L-R Circuit = Electric Current*e^(-Time Period of Progressive Wave/(Inductance/Resistance)) to calculate the Decay of Current in L-R Circuit, The Decay of current in LR circuit formula is defined as the rate at which the current decays in an LR circuit. Decay of Current in L-R Circuit is denoted by Idecay symbol.

How to calculate Decay of Current in LR circuit using this online calculator? To use this online calculator for Decay of Current in LR circuit, enter Electric Current (ip), Time Period of Progressive Wave (Tw), Inductance (L) & Resistance (R) and hit the calculate button. Here is how the Decay of Current in LR circuit calculation can be explained with given input values -> 0.021959 = 2.2*e^(-2.6/(5.7/10.1)).

FAQ

What is Decay of Current in LR circuit?
The Decay of current in LR circuit formula is defined as the rate at which the current decays in an LR circuit and is represented as Idecay = ip*e^(-Tw/(L/R)) or Decay of Current in L-R Circuit = Electric Current*e^(-Time Period of Progressive Wave/(Inductance/Resistance)). Electric Current is the time rate of flow of charge through a cross sectional area, Time period of progressive wave is the time taken by a wave to complete one oscillation, Inductance is the tendency of an electric conductor to oppose a change in the electric current flowing through it & Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
How to calculate Decay of Current in LR circuit?
The Decay of current in LR circuit formula is defined as the rate at which the current decays in an LR circuit is calculated using Decay of Current in L-R Circuit = Electric Current*e^(-Time Period of Progressive Wave/(Inductance/Resistance)). To calculate Decay of Current in LR circuit, you need Electric Current (ip), Time Period of Progressive Wave (Tw), Inductance (L) & Resistance (R). With our tool, you need to enter the respective value for Electric Current, Time Period of Progressive Wave, Inductance & Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!