D.O Saturation for Sewage when Correction Factor is 0.8 Solution

STEP 0: Pre-Calculation Summary
Formula Used
D.O Saturation when Correction Factor is 0.8 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.8*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen
DO0.8 = ((N*9.17)/(Ns*0.8*(1.024)^(T-20)))+DL
This formula uses 5 Variables
Variables Used
D.O Saturation when Correction Factor is 0.8 - (Measured in Kilogram per Cubic Meter) - D.O Saturation when Correction Factor is 0.8 is the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 80% of the theoretical D.O. saturation level.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Oxygen Transfer Capacity - (Measured in Kilogram per Second per Watt) - Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
Operation Dissolved Oxygen - (Measured in Kilogram per Cubic Meter) - Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion ​here)
Oxygen Transfer Capacity: 2.03 Kilogram per Hour per Kilowatt --> 5.63888888888889E-07 Kilogram per Second per Watt (Check conversion ​here)
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
Operation Dissolved Oxygen: 2.01 Milligram per Liter --> 0.00201 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
DO0.8 = ((N*9.17)/(Ns*0.8*(1.024)^(T-20)))+DL --> ((8.33333333333333E-07*9.17)/(5.63888888888889E-07*0.8*(1.024)^(85-20)))+0.00201
Evaluating ... ...
DO0.8 = 3.6278395484253
STEP 3: Convert Result to Output's Unit
3.6278395484253 Kilogram per Cubic Meter -->3627.8395484253 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
3627.8395484253 3627.84 Milligram per Liter <-- D.O Saturation when Correction Factor is 0.8
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

D.O Saturation Calculators

Dissolved Oxygen Saturation for Sewage
​ Go Dissolved Oxygen Saturation = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Correction Factor*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen
D.O Saturation for Sewage when Correction Factor is 0.85
​ Go D.O Saturation when Correction Factor is 0.85 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.85*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen
D.O Saturation for Sewage when Correction Factor is 0.8
​ Go D.O Saturation when Correction Factor is 0.8 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.8*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen

D.O Saturation for Sewage when Correction Factor is 0.8 Formula

D.O Saturation when Correction Factor is 0.8 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.8*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen
DO0.8 = ((N*9.17)/(Ns*0.8*(1.024)^(T-20)))+DL

What is dissolved oxygen ?

Dissolved Oxygen is the amount of gaseous oxygen (O2) dissolved in the water. Oxygen enters the water by direct absorption from the atmosphere, by rapid movement, or as a waste product of plant photosynthesis.

How to Calculate D.O Saturation for Sewage when Correction Factor is 0.8?

D.O Saturation for Sewage when Correction Factor is 0.8 calculator uses D.O Saturation when Correction Factor is 0.8 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.8*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen to calculate the D.O Saturation when Correction Factor is 0.8, The D.O Saturation for Sewage when Correction Factor is 0.8 formula is defined as the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 80% of the theoretical D.O. saturation level. D.O Saturation when Correction Factor is 0.8 is denoted by DO0.8 symbol.

How to calculate D.O Saturation for Sewage when Correction Factor is 0.8 using this online calculator? To use this online calculator for D.O Saturation for Sewage when Correction Factor is 0.8, enter Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Temperature (T) & Operation Dissolved Oxygen (DL) and hit the calculate button. Here is how the D.O Saturation for Sewage when Correction Factor is 0.8 calculation can be explained with given input values -> 3.6E+6 = ((8.33333333333333E-07*9.17)/(5.63888888888889E-07*0.8*(1.024)^(85-20)))+0.00201.

FAQ

What is D.O Saturation for Sewage when Correction Factor is 0.8?
The D.O Saturation for Sewage when Correction Factor is 0.8 formula is defined as the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 80% of the theoretical D.O. saturation level and is represented as DO0.8 = ((N*9.17)/(Ns*0.8*(1.024)^(T-20)))+DL or D.O Saturation when Correction Factor is 0.8 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.8*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen. Oxygen Transferred is the amount of oxygen that is moved from the air into the water, Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water, Temperature is the degree or intensity of heat present in a substance or object & Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
How to calculate D.O Saturation for Sewage when Correction Factor is 0.8?
The D.O Saturation for Sewage when Correction Factor is 0.8 formula is defined as the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 80% of the theoretical D.O. saturation level is calculated using D.O Saturation when Correction Factor is 0.8 = ((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*0.8*(1.024)^(Temperature-20)))+Operation Dissolved Oxygen. To calculate D.O Saturation for Sewage when Correction Factor is 0.8, you need Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Temperature (T) & Operation Dissolved Oxygen (DL). With our tool, you need to enter the respective value for Oxygen Transferred, Oxygen Transfer Capacity, Temperature & Operation Dissolved Oxygen and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!