Cross-sectional Area of Well given Specific Capacity for Fine Sand Solution

STEP 0: Pre-Calculation Summary
Formula Used
Cross-Sectional Area of Well = Discharge in Well/(0.5*Constant Depression Head for Fine Soil)
Acsw = Q/(0.5*Hf)
This formula uses 3 Variables
Variables Used
Cross-Sectional Area of Well - (Measured in Square Meter) - Cross-Sectional Area of Well is the the surface area of the interior opening of the well.
Discharge in Well - (Measured in Cubic Meter per Second) - Discharge in Well is the rate of flow of a liquid in well.
Constant Depression Head for Fine Soil - Constant Depression Head for Fine Soil is the difference of level of waters table and the water level in the well.
STEP 1: Convert Input(s) to Base Unit
Discharge in Well: 0.99 Cubic Meter per Second --> 0.99 Cubic Meter per Second No Conversion Required
Constant Depression Head for Fine Soil: 0.15 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Acsw = Q/(0.5*Hf) --> 0.99/(0.5*0.15)
Evaluating ... ...
Acsw = 13.2
STEP 3: Convert Result to Output's Unit
13.2 Square Meter --> No Conversion Required
FINAL ANSWER
13.2 Square Meter <-- Cross-Sectional Area of Well
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Cross Sectional Area of Well Calculators

Cross-sectional Area of Well given Specific Capacity
​ LaTeX ​ Go Cross-Sectional Area given Specific Capacity = Constant Dependent on Base Soil/Specific Capacity
Cross-sectional Area of Well given Specific Capacity for Clay Soil
​ LaTeX ​ Go Cross-Sectional Area of Well = Discharge in Well/(0.25*Constant Depression Head for Clay Soil)
Cross-sectional Area of Well given Specific Capacity for Coarse Sand
​ LaTeX ​ Go Cross-Sectional Area of Well = Discharge in Well/(1*Constant Depression Head for Coarse Sand)
Cross-sectional Area of Well given Specific Capacity for Fine Sand
​ LaTeX ​ Go Cross-Sectional Area of Well = Discharge in Well/(0.5*Constant Depression Head for Fine Soil)

Cross-sectional Area of Well given Specific Capacity for Fine Sand Formula

​LaTeX ​Go
Cross-Sectional Area of Well = Discharge in Well/(0.5*Constant Depression Head for Fine Soil)
Acsw = Q/(0.5*Hf)

What is Fine Sand?

A Fine sand refers to a type of sand with small particle sizes, typically ranging from 0.075 to 0.425 millimeters in diameter. It is part of the soil classification system, where sand is divided into different grades based on particle size. Fine sand is finer than medium and coarse sand but coarser than silt. In the context of wells or groundwater systems, fine sand can influence water flow and percolation rates. If a well is drilled in fine sand, water might flow more slowly compared to wells in coarser materials like gravel.

How to Calculate Cross-sectional Area of Well given Specific Capacity for Fine Sand?

Cross-sectional Area of Well given Specific Capacity for Fine Sand calculator uses Cross-Sectional Area of Well = Discharge in Well/(0.5*Constant Depression Head for Fine Soil) to calculate the Cross-Sectional Area of Well, The Cross-sectional Area of Well given Specific Capacity for Fine Sand formula is defined as the calculation of value of cross-sectional area of well when we have prior information of specific capacity of fine sand. Cross-Sectional Area of Well is denoted by Acsw symbol.

How to calculate Cross-sectional Area of Well given Specific Capacity for Fine Sand using this online calculator? To use this online calculator for Cross-sectional Area of Well given Specific Capacity for Fine Sand, enter Discharge in Well (Q) & Constant Depression Head for Fine Soil (Hf) and hit the calculate button. Here is how the Cross-sectional Area of Well given Specific Capacity for Fine Sand calculation can be explained with given input values -> 13.46667 = 0.99/(0.5*0.15).

FAQ

What is Cross-sectional Area of Well given Specific Capacity for Fine Sand?
The Cross-sectional Area of Well given Specific Capacity for Fine Sand formula is defined as the calculation of value of cross-sectional area of well when we have prior information of specific capacity of fine sand and is represented as Acsw = Q/(0.5*Hf) or Cross-Sectional Area of Well = Discharge in Well/(0.5*Constant Depression Head for Fine Soil). Discharge in Well is the rate of flow of a liquid in well & Constant Depression Head for Fine Soil is the difference of level of waters table and the water level in the well.
How to calculate Cross-sectional Area of Well given Specific Capacity for Fine Sand?
The Cross-sectional Area of Well given Specific Capacity for Fine Sand formula is defined as the calculation of value of cross-sectional area of well when we have prior information of specific capacity of fine sand is calculated using Cross-Sectional Area of Well = Discharge in Well/(0.5*Constant Depression Head for Fine Soil). To calculate Cross-sectional Area of Well given Specific Capacity for Fine Sand, you need Discharge in Well (Q) & Constant Depression Head for Fine Soil (Hf). With our tool, you need to enter the respective value for Discharge in Well & Constant Depression Head for Fine Soil and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Cross-Sectional Area of Well?
In this formula, Cross-Sectional Area of Well uses Discharge in Well & Constant Depression Head for Fine Soil. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Cross-Sectional Area of Well = Discharge in Well/(0.25*Constant Depression Head for Clay Soil)
  • Cross-Sectional Area of Well = Discharge in Well/(1*Constant Depression Head for Coarse Sand)
  • Cross-Sectional Area of Well = Discharge in Well/(Percolation Intensity Coefficient*Depression Height)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!