Critical Radius of Insulation of Cylinder Solution

STEP 0: Pre-Calculation Summary
Formula Used
Critical Radius of Insulation = Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient
Rc = Kinsulation/houtside
This formula uses 3 Variables
Variables Used
Critical Radius of Insulation - (Measured in Meter) - Critical Radius of Insulation is the radius of insulation at which there is maximum heat transfer and increase or decrease in its value will lead to an overall decrease in heat transfer.
Thermal Conductivity of Insulation - (Measured in Watt per Meter per K) - Thermal Conductivity of Insulation is defined as the ability of insulating material to transmit heat.
External Convection Heat Transfer Coefficient - (Measured in Watt per Square Meter per Kelvin) - External Convection Heat Transfer Coefficient is the proportionality constant between the heat flux and the thermodynamic driving force for the flow of heat in case of convective heat transfer.
STEP 1: Convert Input(s) to Base Unit
Thermal Conductivity of Insulation: 21 Watt per Meter per K --> 21 Watt per Meter per K No Conversion Required
External Convection Heat Transfer Coefficient: 9.8 Watt per Square Meter per Kelvin --> 9.8 Watt per Square Meter per Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rc = Kinsulation/houtside --> 21/9.8
Evaluating ... ...
Rc = 2.14285714285714
STEP 3: Convert Result to Output's Unit
2.14285714285714 Meter --> No Conversion Required
FINAL ANSWER
2.14285714285714 2.142857 Meter <-- Critical Radius of Insulation
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishan Gupta
Birla Institute of Technology & Science (BITS), Pilani
Ishan Gupta has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Prashant Singh
K J Somaiya College of science (K J Somaiya), Mumbai
Prashant Singh has verified this Calculator and 500+ more calculators!

Critical Thickness of Insulation Calculators

Critical Radius of Insulation of Hollow Sphere
​ LaTeX ​ Go Critical Radius of Insulation = 2*Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient
Critical Radius of Insulation of Cylinder
​ LaTeX ​ Go Critical Radius of Insulation = Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient
Volumetric Heat Generation in Current Carrying Electrical Conductor
​ LaTeX ​ Go Volumetric Heat Generation = (Electric Current Density^2)*Resistivity

Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance Calculators

Biot Number using Characteristic Length
​ LaTeX ​ Go Biot Number = (Heat Transfer Coefficient*Characteristic Length)/(Thermal Conductivity of Fin)
Correction Length for Cylindrical Fin with Non-Adiabatic Tip
​ LaTeX ​ Go Correction Length for Cylindrical Fin = Length of Fin+(Diameter of Cylindrical Fin/4)
Correction Length for Thin Rectangular Fin with Non-Adiabatic Tip
​ LaTeX ​ Go Correction Length for Thin Rectangular Fin = Length of Fin+(Thickness of Fin/2)
Correction Length for Square Fin with Non-Adiabatic Tip
​ LaTeX ​ Go Correction Length for Sqaure Fin = Length of Fin+(Width of Fin/4)

Critical Radius of Insulation of Cylinder Formula

​LaTeX ​Go
Critical Radius of Insulation = Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient
Rc = Kinsulation/houtside

Critical Radius of Insulation of a Cylinder

Critical Radius of Insulation of a Cylinder is the radius of insulation at which there is maximum heat transfer and increase or decrease in its value will lead to an overall decrease in heat transfer.

How to Calculate Critical Radius of Insulation of Cylinder?

Critical Radius of Insulation of Cylinder calculator uses Critical Radius of Insulation = Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient to calculate the Critical Radius of Insulation, Critical Radius of Insulation of Cylinder is the radius of insulation at which there is maximum heat transfer and an increase or decrease in its value will lead to an overall decrease in heat transfer. Critical Radius of Insulation is denoted by Rc symbol.

How to calculate Critical Radius of Insulation of Cylinder using this online calculator? To use this online calculator for Critical Radius of Insulation of Cylinder, enter Thermal Conductivity of Insulation (Kinsulation) & External Convection Heat Transfer Coefficient (houtside) and hit the calculate button. Here is how the Critical Radius of Insulation of Cylinder calculation can be explained with given input values -> 2.142857 = 21/9.8.

FAQ

What is Critical Radius of Insulation of Cylinder?
Critical Radius of Insulation of Cylinder is the radius of insulation at which there is maximum heat transfer and an increase or decrease in its value will lead to an overall decrease in heat transfer and is represented as Rc = Kinsulation/houtside or Critical Radius of Insulation = Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient. Thermal Conductivity of Insulation is defined as the ability of insulating material to transmit heat & External Convection Heat Transfer Coefficient is the proportionality constant between the heat flux and the thermodynamic driving force for the flow of heat in case of convective heat transfer.
How to calculate Critical Radius of Insulation of Cylinder?
Critical Radius of Insulation of Cylinder is the radius of insulation at which there is maximum heat transfer and an increase or decrease in its value will lead to an overall decrease in heat transfer is calculated using Critical Radius of Insulation = Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient. To calculate Critical Radius of Insulation of Cylinder, you need Thermal Conductivity of Insulation (Kinsulation) & External Convection Heat Transfer Coefficient (houtside). With our tool, you need to enter the respective value for Thermal Conductivity of Insulation & External Convection Heat Transfer Coefficient and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Critical Radius of Insulation?
In this formula, Critical Radius of Insulation uses Thermal Conductivity of Insulation & External Convection Heat Transfer Coefficient. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Critical Radius of Insulation = 2*Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient
  • Critical Radius of Insulation = 2*Thermal Conductivity of Insulation/External Convection Heat Transfer Coefficient
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!