Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters Solution

STEP 0: Pre-Calculation Summary
Formula Used
Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature
T'c = ((p+(a/(((Vm+c)^2))))*((Vm-b')/[R]))/Tr
This formula uses 1 Constants, 7 Variables
Constants Used
[R] - Universal gas constant Value Taken As 8.31446261815324
Variables Used
Critical Temperature For Clausius Model - (Measured in Kelvin) - Critical Temperature For Clausius Model is the highest temperature at which the substance can exist as a liquid. At this phase boundaries vanish, the substance can exist both as a liquid and vapor.
Pressure - (Measured in Pascal) - Pressure is the force applied perpendicular to the surface of an object per unit area over which that force is distributed.
Clausius Parameter a - Clausius parameter a is an empirical parameter characteristic to equation obtained from Clausius model of real gas.
Molar Volume - (Measured in Cubic Meter per Mole) - Molar Volume is the volume occupied by one mole of a real gas at standard temperature and pressure.
Clausius Parameter c - Clausius parameter c is an empirical parameter characteristic to equation obtained from Clausius model of real gas.
Clausius Parameter b for Real Gas - Clausius Parameter b for Real Gas is an empirical parameter characteristic to equation obtained from Clausius model of real gas.
Reduced Temperature - Reduced Temperature is the ratio of the actual temperature of the fluid to its critical temperature. It is dimensionless.
STEP 1: Convert Input(s) to Base Unit
Pressure: 800 Pascal --> 800 Pascal No Conversion Required
Clausius Parameter a: 0.1 --> No Conversion Required
Molar Volume: 22.4 Cubic Meter per Mole --> 22.4 Cubic Meter per Mole No Conversion Required
Clausius Parameter c: 0.0002 --> No Conversion Required
Clausius Parameter b for Real Gas: 0.00243 --> No Conversion Required
Reduced Temperature: 10 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T'c = ((p+(a/(((Vm+c)^2))))*((Vm-b')/[R]))/Tr --> ((800+(0.1/(((22.4+0.0002)^2))))*((22.4-0.00243)/[R]))/10
Evaluating ... ...
T'c = 215.504732976977
STEP 3: Convert Result to Output's Unit
215.504732976977 Kelvin --> No Conversion Required
FINAL ANSWER
215.504732976977 215.5047 Kelvin <-- Critical Temperature For Clausius Model
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has created this Calculator and 800+ more calculators!
Verifier Image
Verified by Prashant Singh
K J Somaiya College of science (K J Somaiya), Mumbai
Prashant Singh has verified this Calculator and 500+ more calculators!

Critical Temperature Calculators

Critical Temperature of Real Gas using Clausius Equation given Reduced and Critical Parameters
​ LaTeX ​ Go Critical Temperature For Clausius Model = (((Reduced Pressure*Critical Pressure of Real Gas)+(Clausius Parameter a/((((Reduced Molar Volume for Real Gas*Critical Molar Volume)+Clausius Parameter c)^2))))*(((Reduced Molar Volume for Real Gas*Critical Molar Volume)-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature
Critical Temperature of Real Gas using Clausius Equation given Actual and Critical Parameters
​ LaTeX ​ Go Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Temperature of Real Gas
Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters
​ LaTeX ​ Go Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature
Critical Temperature of Real Gas given Clausius Parameter a
​ LaTeX ​ Go Critical Temperature For Clausius Model = ((Clausius Parameter a*64*Critical Pressure of Real Gas)/(27*([R]^2)))^(1/3)

Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters Formula

​LaTeX ​Go
Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature
T'c = ((p+(a/(((Vm+c)^2))))*((Vm-b')/[R]))/Tr

What are Real Gases?

Real gases are non ideal gases whose molecules occupy space and have interactions; consequently, they do not adhere to the ideal gas law. To understand the behavior of real gases, the following must be taken into account:
- compressibility effects;
- variable specific heat capacity;
- van der Waals forces;
- non-equilibrium thermodynamic effects;
- issues with molecular dissociation and elementary reactions with variable composition.

How to Calculate Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters?

Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters calculator uses Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature to calculate the Critical Temperature For Clausius Model, The Critical Temperature of real gas using Clausius equation given reduced and actual parameters formula is defined as the highest temperature at which the substance can exist as a liquid. Critical Temperature For Clausius Model is denoted by T'c symbol.

How to calculate Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters using this online calculator? To use this online calculator for Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters, enter Pressure (p), Clausius Parameter a (a), Molar Volume (Vm), Clausius Parameter c (c), Clausius Parameter b for Real Gas (b') & Reduced Temperature (Tr) and hit the calculate button. Here is how the Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters calculation can be explained with given input values -> 215.5047 = ((800+(0.1/(((22.4+0.0002)^2))))*((22.4-0.00243)/[R]))/10.

FAQ

What is Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters?
The Critical Temperature of real gas using Clausius equation given reduced and actual parameters formula is defined as the highest temperature at which the substance can exist as a liquid and is represented as T'c = ((p+(a/(((Vm+c)^2))))*((Vm-b')/[R]))/Tr or Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature. Pressure is the force applied perpendicular to the surface of an object per unit area over which that force is distributed, Clausius parameter a is an empirical parameter characteristic to equation obtained from Clausius model of real gas, Molar Volume is the volume occupied by one mole of a real gas at standard temperature and pressure, Clausius parameter c is an empirical parameter characteristic to equation obtained from Clausius model of real gas, Clausius Parameter b for Real Gas is an empirical parameter characteristic to equation obtained from Clausius model of real gas & Reduced Temperature is the ratio of the actual temperature of the fluid to its critical temperature. It is dimensionless.
How to calculate Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters?
The Critical Temperature of real gas using Clausius equation given reduced and actual parameters formula is defined as the highest temperature at which the substance can exist as a liquid is calculated using Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature. To calculate Critical Temperature of Real Gas using Clausius Equation given Reduced and Actual Parameters, you need Pressure (p), Clausius Parameter a (a), Molar Volume (Vm), Clausius Parameter c (c), Clausius Parameter b for Real Gas (b') & Reduced Temperature (Tr). With our tool, you need to enter the respective value for Pressure, Clausius Parameter a, Molar Volume, Clausius Parameter c, Clausius Parameter b for Real Gas & Reduced Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Critical Temperature For Clausius Model?
In this formula, Critical Temperature For Clausius Model uses Pressure, Clausius Parameter a, Molar Volume, Clausius Parameter c, Clausius Parameter b for Real Gas & Reduced Temperature. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Critical Temperature For Clausius Model = ((Pressure+(Clausius Parameter a/(((Molar Volume+Clausius Parameter c)^2))))*((Molar Volume-Clausius Parameter b for Real Gas)/[R]))/Temperature of Real Gas
  • Critical Temperature For Clausius Model = (((Reduced Pressure*Critical Pressure of Real Gas)+(Clausius Parameter a/((((Reduced Molar Volume for Real Gas*Critical Molar Volume)+Clausius Parameter c)^2))))*(((Reduced Molar Volume for Real Gas*Critical Molar Volume)-Clausius Parameter b for Real Gas)/[R]))/Reduced Temperature
  • Critical Temperature For Clausius Model = ((Clausius Parameter a*64*Critical Pressure of Real Gas)/(27*([R]^2)))^(1/3)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!