Critical Slenderness Ratio for Aluminium Columns Solution

STEP 0: Pre-Calculation Summary
Formula Used
Slenderness Ratio = sqrt(51000000/(Allowable Load/Section Area of Column))
λ = sqrt(51000000/(Q/A))
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Slenderness Ratio - Slenderness Ratio is the ratio of the length of a column and the least radius of gyration of its cross section.
Allowable Load - (Measured in Newton) - The Allowable Load is the maximum working load that can be applied on the structure.
Section Area of Column - (Measured in Square Meter) - The Section Area of Column is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
STEP 1: Convert Input(s) to Base Unit
Allowable Load: 633.213 Newton --> 633.213 Newton No Conversion Required
Section Area of Column: 52900 Square Millimeter --> 0.0529 Square Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
λ = sqrt(51000000/(Q/A)) --> sqrt(51000000/(633.213/0.0529))
Evaluating ... ...
λ = 65.2736671949162
STEP 3: Convert Result to Output's Unit
65.2736671949162 --> No Conversion Required
FINAL ANSWER
65.2736671949162 65.27367 <-- Slenderness Ratio
(Calculation completed in 00.008 seconds)

Credits

Creator Image
Created by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Aluminium Column Design Calculators

Ultimate Load per Area for Aluminium Columns given Allowable Load and Section Area
​ LaTeX ​ Go Ultimate Load = (1.95*(Allowable Load/Section Area of Column))*Section Area of Column
Critical Slenderness Ratio for Aluminium Columns
​ LaTeX ​ Go Slenderness Ratio = sqrt(51000000/(Allowable Load/Section Area of Column))
Ultimate Load per Area for Aluminium Columns
​ LaTeX ​ Go Ultimate Load = (34000-88*Slenderness Ratio)*Section Area of Column

Critical Slenderness Ratio for Aluminium Columns Formula

​LaTeX ​Go
Slenderness Ratio = sqrt(51000000/(Allowable Load/Section Area of Column))
λ = sqrt(51000000/(Q/A))

What is Slenderness Ratio?

It is defined as the effective length of the column and the least radius of gyration, the latter defined by the area of the cross-section of the column and is the second moment of the area of the cross-section.

What is the purpose of Slenderness Ratio?

It is used extensively for finding out the design load as well as in classifying various columns in short/intermediate/long. The slenderness ratio of a column gives an indication of buckling failure in the column. The more the slenderness ratio, more the tendency of a column to fail by buckling effect in that direction.

How to Calculate Critical Slenderness Ratio for Aluminium Columns?

Critical Slenderness Ratio for Aluminium Columns calculator uses Slenderness Ratio = sqrt(51000000/(Allowable Load/Section Area of Column)) to calculate the Slenderness Ratio, The Critical Slenderness Ratio for Aluminium Columns formula is defined as the effective length of the column and is the least radius of gyration, the latter defined by where is the area of the cross-section of the column and is the second moment of area of the cross-section. Slenderness Ratio is denoted by λ symbol.

How to calculate Critical Slenderness Ratio for Aluminium Columns using this online calculator? To use this online calculator for Critical Slenderness Ratio for Aluminium Columns, enter Allowable Load (Q) & Section Area of Column (A) and hit the calculate button. Here is how the Critical Slenderness Ratio for Aluminium Columns calculation can be explained with given input values -> 1023.25 = sqrt(51000000/(633.213/0.0529)).

FAQ

What is Critical Slenderness Ratio for Aluminium Columns?
The Critical Slenderness Ratio for Aluminium Columns formula is defined as the effective length of the column and is the least radius of gyration, the latter defined by where is the area of the cross-section of the column and is the second moment of area of the cross-section and is represented as λ = sqrt(51000000/(Q/A)) or Slenderness Ratio = sqrt(51000000/(Allowable Load/Section Area of Column)). The Allowable Load is the maximum working load that can be applied on the structure & The Section Area of Column is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
How to calculate Critical Slenderness Ratio for Aluminium Columns?
The Critical Slenderness Ratio for Aluminium Columns formula is defined as the effective length of the column and is the least radius of gyration, the latter defined by where is the area of the cross-section of the column and is the second moment of area of the cross-section is calculated using Slenderness Ratio = sqrt(51000000/(Allowable Load/Section Area of Column)). To calculate Critical Slenderness Ratio for Aluminium Columns, you need Allowable Load (Q) & Section Area of Column (A). With our tool, you need to enter the respective value for Allowable Load & Section Area of Column and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!