Critical Frequency of Ionosphere Solution

STEP 0: Pre-Calculation Summary
Formula Used
Critical Frequency of Ionosphere = 9*sqrt(Electron Density)
Fc = 9*sqrt(Nmax)
This formula uses 1 Functions, 2 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Critical Frequency of Ionosphere - (Measured in Hertz) - Critical Frequency of Ionosphere is the highest magnitude of frequency above which the waves penetrate the ionosphere and below which the waves are reflected back from the ionosphere.
Electron Density - (Measured in 1 per Cubic Meter) - Electron Density refers to the concentration or number of electrons per unit volume in a given material or medium.
STEP 1: Convert Input(s) to Base Unit
Electron Density: 20000000000 1 per Cubic Centimeter --> 2E+16 1 per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Fc = 9*sqrt(Nmax) --> 9*sqrt(2E+16)
Evaluating ... ...
Fc = 1272792206.13579
STEP 3: Convert Result to Output's Unit
1272792206.13579 Hertz --> No Conversion Required
FINAL ANSWER
1272792206.13579 1.3E+9 Hertz <-- Critical Frequency of Ionosphere
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Wave Propagation Calculators

Refractive Index of Ionosphere
​ LaTeX ​ Go Refractive Index = sqrt(1-((81*Electron Density)/Operating Frequency^2))
Maximum Usable Frequency in F-region
​ LaTeX ​ Go Maximum Usable Frequency = Critical Frequency/cos(Angle of Incidence)
Electron Density
​ LaTeX ​ Go Electron Density = ((1-Refractive Index^2)*Operating Frequency^2)/81
Critical Frequency of Ionosphere
​ LaTeX ​ Go Critical Frequency of Ionosphere = 9*sqrt(Electron Density)

Critical Frequency of Ionosphere Formula

​LaTeX ​Go
Critical Frequency of Ionosphere = 9*sqrt(Electron Density)
Fc = 9*sqrt(Nmax)

What is Ionospheric Propagation?

In radio communication, skywave or skip refers to the propagation of radio waves reflected or refracted back toward Earth from the ionosphere, an electrically charged layer of the upper atmosphere. Line-of-sight propagation, in which radio waves travel in a straight line, the dominant mode at higher frequencies.

How to Calculate Critical Frequency of Ionosphere?

Critical Frequency of Ionosphere calculator uses Critical Frequency of Ionosphere = 9*sqrt(Electron Density) to calculate the Critical Frequency of Ionosphere, The Critical Frequency of Ionosphere formula is defined as the highest magnitude of frequency above which the waves penetrate the ionosphere and below which the waves are reflected back from the ionosphere. Critical Frequency of Ionosphere is denoted by Fc symbol.

How to calculate Critical Frequency of Ionosphere using this online calculator? To use this online calculator for Critical Frequency of Ionosphere, enter Electron Density (Nmax) and hit the calculate button. Here is how the Critical Frequency of Ionosphere calculation can be explained with given input values -> 1.3E+9 = 9*sqrt(2E+16).

FAQ

What is Critical Frequency of Ionosphere?
The Critical Frequency of Ionosphere formula is defined as the highest magnitude of frequency above which the waves penetrate the ionosphere and below which the waves are reflected back from the ionosphere and is represented as Fc = 9*sqrt(Nmax) or Critical Frequency of Ionosphere = 9*sqrt(Electron Density). Electron Density refers to the concentration or number of electrons per unit volume in a given material or medium.
How to calculate Critical Frequency of Ionosphere?
The Critical Frequency of Ionosphere formula is defined as the highest magnitude of frequency above which the waves penetrate the ionosphere and below which the waves are reflected back from the ionosphere is calculated using Critical Frequency of Ionosphere = 9*sqrt(Electron Density). To calculate Critical Frequency of Ionosphere, you need Electron Density (Nmax). With our tool, you need to enter the respective value for Electron Density and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!