Critical Depth given Maximum Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Critical Depth = (Peak Discharge/(Width of Throat*Critical Velocity))
dc = (Qp/(Wt*Vc))
This formula uses 4 Variables
Variables Used
Critical Depth - (Measured in Meter) - Critical Depth occurs when the flow in a channel has a minimum specific energy. Specific energy refers to the sum of the depth of flow and the velocity head.
Peak Discharge - (Measured in Cubic Meter per Second) - Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Width of Throat - (Measured in Meter) - Width of Throat is the narrowest section of a conduit or channel, such as in a venturi meter or flume.
Critical Velocity - (Measured in Meter per Second) - The Critical velocity is the greatest velocity with which a fluid can flow through a given conduit without becoming turbulent.
STEP 1: Convert Input(s) to Base Unit
Peak Discharge: 39.77 Cubic Meter per Second --> 39.77 Cubic Meter per Second No Conversion Required
Width of Throat: 3 Meter --> 3 Meter No Conversion Required
Critical Velocity: 5.06 Meter per Second --> 5.06 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
dc = (Qp/(Wt*Vc)) --> (39.77/(3*5.06))
Evaluating ... ...
dc = 2.61989459815547
STEP 3: Convert Result to Output's Unit
2.61989459815547 Meter --> No Conversion Required
FINAL ANSWER
2.61989459815547 2.619895 Meter <-- Critical Depth
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

Critical Depth Calculators

Critical Depth at Different Discharges
​ LaTeX ​ Go Critical Depth = ((Environmental Discharge)^2/(Acceleration due to Gravity*(Width of Throat)^2))^(1/3)
Critical Depth given Discharge through Control Section
​ LaTeX ​ Go Critical Depth = (Environmental Discharge/(Width of Throat*Critical Velocity))
Critical Depth in Control Section
​ LaTeX ​ Go Critical Depth = ((Critical Velocity)^2/Acceleration due to Gravity)
Critical Depth given Depth of Parabolic Channel
​ LaTeX ​ Go Critical Depth = (Depth/1.55)

Critical Depth given Maximum Discharge Formula

​LaTeX ​Go
Critical Depth = (Peak Discharge/(Width of Throat*Critical Velocity))
dc = (Qp/(Wt*Vc))

What is Critical Depth?

Critical depth is also the depth of maximum discharge, when the specific energy is held constant.Critical depth is defined as the depth of flow where energy is at a minimum for a particular discharge.

How to Calculate Critical Depth given Maximum Discharge?

Critical Depth given Maximum Discharge calculator uses Critical Depth = (Peak Discharge/(Width of Throat*Critical Velocity)) to calculate the Critical Depth, The Critical Depth given Maximum Discharge formula is defined as the depth of flow where energy is at a minimum for a maximum discharge. Critical Depth is denoted by dc symbol.

How to calculate Critical Depth given Maximum Discharge using this online calculator? To use this online calculator for Critical Depth given Maximum Discharge, enter Peak Discharge (Qp), Width of Throat (Wt) & Critical Velocity (Vc) and hit the calculate button. Here is how the Critical Depth given Maximum Discharge calculation can be explained with given input values -> 0.263505 = (39.77/(3*5.06)).

FAQ

What is Critical Depth given Maximum Discharge?
The Critical Depth given Maximum Discharge formula is defined as the depth of flow where energy is at a minimum for a maximum discharge and is represented as dc = (Qp/(Wt*Vc)) or Critical Depth = (Peak Discharge/(Width of Throat*Critical Velocity)). Peak Discharge is the maximum volume flow rate passing a particular location during an event, Width of Throat is the narrowest section of a conduit or channel, such as in a venturi meter or flume & The Critical velocity is the greatest velocity with which a fluid can flow through a given conduit without becoming turbulent.
How to calculate Critical Depth given Maximum Discharge?
The Critical Depth given Maximum Discharge formula is defined as the depth of flow where energy is at a minimum for a maximum discharge is calculated using Critical Depth = (Peak Discharge/(Width of Throat*Critical Velocity)). To calculate Critical Depth given Maximum Discharge, you need Peak Discharge (Qp), Width of Throat (Wt) & Critical Velocity (Vc). With our tool, you need to enter the respective value for Peak Discharge, Width of Throat & Critical Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Critical Depth?
In this formula, Critical Depth uses Peak Discharge, Width of Throat & Critical Velocity. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Critical Depth = ((Critical Velocity)^2/Acceleration due to Gravity)
  • Critical Depth = (Environmental Discharge/(Width of Throat*Critical Velocity))
  • Critical Depth = ((Environmental Discharge)^2/(Acceleration due to Gravity*(Width of Throat)^2))^(1/3)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!