Correction Factor given Oxygen Transfer Capacity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17))
Cf = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17))
This formula uses 6 Variables
Variables Used
Correction Factor - Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Oxygen Transfer Capacity - (Measured in Kilogram per Second per Watt) - Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Dissolved Oxygen Saturation - (Measured in Kilogram per Cubic Meter) - Dissolved Oxygen Saturation is the maximum amount of oxygen that can be dissolved in water at a given temperature and pressure.
Operation Dissolved Oxygen - (Measured in Kilogram per Cubic Meter) - Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion ​here)
Oxygen Transfer Capacity: 2.03 Kilogram per Hour per Kilowatt --> 5.63888888888889E-07 Kilogram per Second per Watt (Check conversion ​here)
Dissolved Oxygen Saturation: 5803 Milligram per Liter --> 5.803 Kilogram per Cubic Meter (Check conversion ​here)
Operation Dissolved Oxygen: 2.01 Milligram per Liter --> 0.00201 Kilogram per Cubic Meter (Check conversion ​here)
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cf = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17)) --> 8.33333333333333E-07/((5.63888888888889E-07*(5.803-0.00201)*(1.024)^(85-20))/(9.17))
Evaluating ... ...
Cf = 0.500029070682804
STEP 3: Convert Result to Output's Unit
0.500029070682804 --> No Conversion Required
FINAL ANSWER
0.500029070682804 0.500029 <-- Correction Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Oxygen Transfer Capacity Calculators

Oxygen Transfer Capacity under Standard Conditions
​ Go Oxygen Transfer Capacity = Oxygen Transferred/(((Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field Conditions
​ Go Oxygen Transferred = (Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17)
Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen
​ Go Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field given Difference between Saturation and Operation Dissolved Oxygen
​ Go Oxygen Transferred = (Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)

Important Formulas of Oxygen Requirement of the Aeration Tank Calculators

BOD5 given Oxygen Required in Aeration Tank
​ Go BOD5 given Oxygen Required in Aeration Tank = Ultimate BOD*(Sewage Discharge*(Influent BOD-Effluent BOD))/(Theoretical Oxygen Requirement+(1.42*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge))
BOD5 given Ratio of BOD to Ultimate BOD
​ Go BOD5 given Ratio of BOD to Ultimate BOD = Ratio of BOD to Ultimate BOD*Ultimate BOD
Ratio of BOD to Ultimate BOD
​ Go Ratio of BOD to Ultimate BOD = BOD of 5 days at 20° C/Ultimate BOD
BOD5 when Ratio of BOD to Ultimate BOD is 0.68
​ Go 5 Days BOD = Ultimate BOD*0.68

Correction Factor given Oxygen Transfer Capacity Formula

Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17))
Cf = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17))

What is Aeration Tank?

Aeration in an activated sludge process is based on pumping air into a tank, which promotes the microbial growth in the wastewater. The microbes feed on the organic material, forming flocks which can easily settle out.

How to Calculate Correction Factor given Oxygen Transfer Capacity?

Correction Factor given Oxygen Transfer Capacity calculator uses Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17)) to calculate the Correction Factor, The Correction Factor given Oxygen Transfer Capacity formula is defined as the calculation of the correction factor when we have prior information of oxygen transfer capacity. Correction Factor is denoted by Cf symbol.

How to calculate Correction Factor given Oxygen Transfer Capacity using this online calculator? To use this online calculator for Correction Factor given Oxygen Transfer Capacity, enter Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Dissolved Oxygen Saturation (DS), Operation Dissolved Oxygen (DL) & Temperature (T) and hit the calculate button. Here is how the Correction Factor given Oxygen Transfer Capacity calculation can be explained with given input values -> 0.500029 = 8.33333333333333E-07/((5.63888888888889E-07*(5.803-0.00201)*(1.024)^(85-20))/(9.17)).

FAQ

What is Correction Factor given Oxygen Transfer Capacity?
The Correction Factor given Oxygen Transfer Capacity formula is defined as the calculation of the correction factor when we have prior information of oxygen transfer capacity and is represented as Cf = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17)) or Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17)). Oxygen Transferred is the amount of oxygen that is moved from the air into the water, Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water, Dissolved Oxygen Saturation is the maximum amount of oxygen that can be dissolved in water at a given temperature and pressure, Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Correction Factor given Oxygen Transfer Capacity?
The Correction Factor given Oxygen Transfer Capacity formula is defined as the calculation of the correction factor when we have prior information of oxygen transfer capacity is calculated using Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*(1.024)^(Temperature-20))/(9.17)). To calculate Correction Factor given Oxygen Transfer Capacity, you need Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Dissolved Oxygen Saturation (DS), Operation Dissolved Oxygen (DL) & Temperature (T). With our tool, you need to enter the respective value for Oxygen Transferred, Oxygen Transfer Capacity, Dissolved Oxygen Saturation, Operation Dissolved Oxygen & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Correction Factor?
In this formula, Correction Factor uses Oxygen Transferred, Oxygen Transfer Capacity, Dissolved Oxygen Saturation, Operation Dissolved Oxygen & Temperature. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Correction Factor = Oxygen Transferred/((Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*(1.024)^(Temperature-20))/(9.17))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!