Correction Factor Nc for Rectangle Solution

STEP 0: Pre-Calculation Summary
Formula Used
Correction Factor Nc = 1+(Width of Footing/Length of Footing)*(Bearing Capacity Factor Nq/Bearing Capacity Factor)
N c = 1+(B/L)*(Nq/Nc)
This formula uses 5 Variables
Variables Used
Correction Factor Nc - Correction Factor Nc is the function of angle of internal friction Ø.
Width of Footing - (Measured in Meter) - Width of Footing is the shorter dimension of the footing.
Length of Footing - (Measured in Meter) - Length of Footing is the length of the larger dimension of the footing.
Bearing Capacity Factor Nq - Bearing Capacity Factor Nq used in a bearing capacity equation that correlates with the angle of internal friction of soil.
Bearing Capacity Factor - Bearing Capacity Factor is empirically derived factor used in a bearing capacity equation that usually correlates with the angle of internal friction of the soil.
STEP 1: Convert Input(s) to Base Unit
Width of Footing: 2 Meter --> 2 Meter No Conversion Required
Length of Footing: 4 Meter --> 4 Meter No Conversion Required
Bearing Capacity Factor Nq: 1.98 --> No Conversion Required
Bearing Capacity Factor: 3.1 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
N c = 1+(B/L)*(Nq/Nc) --> 1+(2/4)*(1.98/3.1)
Evaluating ... ...
N c = 1.31935483870968
STEP 3: Convert Result to Output's Unit
1.31935483870968 --> No Conversion Required
FINAL ANSWER
1.31935483870968 1.319355 <-- Correction Factor Nc
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Alithea Fernandes
Don Bosco College of Engineering (DBCE), Goa
Alithea Fernandes has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has verified this Calculator and 50+ more calculators!

Foundation Stability Analysis Calculators

Net Bearing Capacity of Long Footing in Foundation Stability Analysis
​ LaTeX ​ Go Net Bearing Capacity = (Alpha Footing Factor*Undrained Shear Strength of Soil*Bearing Capacity Factor)+(Effective Vertical Shear Stress in Soil*Bearing Capacity Factor Nq)+(Beta Footing Factor*Unit Weight of Soil*Width of Footing*Value of Nγ)
Maximum Bearing Pressure for Eccentric Loading Conventional Case
​ LaTeX ​ Go Maximum Bearing Pressure = (Circumference of Group in Foundation/(Breadth of Dam*Length of Footing))*(1+((6*Eccentricity of the Load on Soil)/Breadth of Dam))
Minimum Bearing Pressure for Eccentric Loading Conventional Case
​ LaTeX ​ Go Bearing Pressure Minimum = (Axial Load on Soil/(Breadth of Dam*Length of Footing))*(1-((6*Eccentricity of the Load on Soil)/Breadth of Dam))
Net Bearing Capacity for Undrained Loading of Cohesive Soils
​ LaTeX ​ Go Net Bearing Capacity = Alpha Footing Factor*Bearing Capacity Factor Nq*Undrained Shear Strength of Soil

Correction Factor Nc for Rectangle Formula

​LaTeX ​Go
Correction Factor Nc = 1+(Width of Footing/Length of Footing)*(Bearing Capacity Factor Nq/Bearing Capacity Factor)
N c = 1+(B/L)*(Nq/Nc)

What is Bearing Capacity Factor?

Bearing capacity factors are empirically derived factors used in a bearing capacity equation that usually correlates with the angle of internal friction of the soil.

How to Calculate Correction Factor Nc for Rectangle?

Correction Factor Nc for Rectangle calculator uses Correction Factor Nc = 1+(Width of Footing/Length of Footing)*(Bearing Capacity Factor Nq/Bearing Capacity Factor) to calculate the Correction Factor Nc, The Correction Factor Nc for Rectangle formula is defined as the shape corrections for bearing-capacity factors of Shallow Foundations. Correction Factor Nc is denoted by N c symbol.

How to calculate Correction Factor Nc for Rectangle using this online calculator? To use this online calculator for Correction Factor Nc for Rectangle, enter Width of Footing (B), Length of Footing (L), Bearing Capacity Factor Nq (Nq) & Bearing Capacity Factor (Nc) and hit the calculate button. Here is how the Correction Factor Nc for Rectangle calculation can be explained with given input values -> 1.319355 = 1+(2/4)*(1.98/3.1).

FAQ

What is Correction Factor Nc for Rectangle?
The Correction Factor Nc for Rectangle formula is defined as the shape corrections for bearing-capacity factors of Shallow Foundations and is represented as N c = 1+(B/L)*(Nq/Nc) or Correction Factor Nc = 1+(Width of Footing/Length of Footing)*(Bearing Capacity Factor Nq/Bearing Capacity Factor). Width of Footing is the shorter dimension of the footing, Length of Footing is the length of the larger dimension of the footing, Bearing Capacity Factor Nq used in a bearing capacity equation that correlates with the angle of internal friction of soil & Bearing Capacity Factor is empirically derived factor used in a bearing capacity equation that usually correlates with the angle of internal friction of the soil.
How to calculate Correction Factor Nc for Rectangle?
The Correction Factor Nc for Rectangle formula is defined as the shape corrections for bearing-capacity factors of Shallow Foundations is calculated using Correction Factor Nc = 1+(Width of Footing/Length of Footing)*(Bearing Capacity Factor Nq/Bearing Capacity Factor). To calculate Correction Factor Nc for Rectangle, you need Width of Footing (B), Length of Footing (L), Bearing Capacity Factor Nq (Nq) & Bearing Capacity Factor (Nc). With our tool, you need to enter the respective value for Width of Footing, Length of Footing, Bearing Capacity Factor Nq & Bearing Capacity Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Correction Factor Nc?
In this formula, Correction Factor Nc uses Width of Footing, Length of Footing, Bearing Capacity Factor Nq & Bearing Capacity Factor. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Correction Factor Nc = 1+(Bearing Capacity Factor Nq/Bearing Capacity Factor)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!