Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well Solution

STEP 0: Pre-Calculation Summary
Formula Used
Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well
G = Qv/Qfe
This formula uses 3 Variables
Variables Used
Correction Factor - Correction Factor refers to the reduced efficiency and altered flow patterns due to the well not extending through the entire aquifer thickness.
Discharge for Partially Penetrating Well - (Measured in Cubic Meter per Second) - Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer.
Discharge for Fully Penetrating Gravity Well - (Measured in Cubic Meter per Second) - Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer.
STEP 1: Convert Input(s) to Base Unit
Discharge for Partially Penetrating Well: 5.08 Cubic Meter per Second --> 5.08 Cubic Meter per Second No Conversion Required
Discharge for Fully Penetrating Gravity Well: 6.12 Cubic Meter per Second --> 6.12 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
G = Qv/Qfe --> 5.08/6.12
Evaluating ... ...
G = 0.830065359477124
STEP 3: Convert Result to Output's Unit
0.830065359477124 --> No Conversion Required
FINAL ANSWER
0.830065359477124 0.830065 <-- Correction Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Partially Penetrating Artesian Well Calculators

Coefficient of Permeability given Discharge for Partially Penetrating Well
​ Go Coefficient of Permeability = Discharge for Partially Penetrating Well/((2*pi*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Aquifer Thickness given Discharge for Partially Penetrating Well
​ Go Aquifer Thickness = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e)))
Thickness of Aquifer given Discharge for Partially Penetrating Well
​ Go Initial Piezometric Surface = Depth of Water+(Discharge for Partially Penetrating Well*(log((Radius of Influence/Radius of Well),e)))/(2*pi*Coefficient of Permeability*Aquifer Thickness*Correction Factor)
Discharge for Partially Penetrating Well
​ Go Discharge for Partially Penetrating Well = (2*pi*Coefficient of Permeability*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water)*Correction Factor)/(log((Radius of Influence/Radius of Well),e))

Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well Formula

Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well
G = Qv/Qfe

What is Discharge?

The amount of fluid passing a section of a stream in unit time is called the discharge. If v is the mean velocity and A is the cross sectional area, the discharge Q is defined by Q = Av which is known as volume flow rate.

How to Calculate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well?

Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well calculator uses Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well to calculate the Correction Factor, Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well formula is defined as a dimensionless quantity that accounts for the reduction in well discharge due to partial penetration of the well screen into the aquifer, providing a correction to the discharge rate of a fully penetrating well. Correction Factor is denoted by G symbol.

How to calculate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well using this online calculator? To use this online calculator for Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well, enter Discharge for Partially Penetrating Well (Qv) & Discharge for Fully Penetrating Gravity Well (Qfe) and hit the calculate button. Here is how the Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well calculation can be explained with given input values -> 10160 = 5.08/6.12.

FAQ

What is Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well?
Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well formula is defined as a dimensionless quantity that accounts for the reduction in well discharge due to partial penetration of the well screen into the aquifer, providing a correction to the discharge rate of a fully penetrating well and is represented as G = Qv/Qfe or Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well. Discharge for Partially Penetrating Well refers to the volume of water extracted from an aquifer when the well does not extend through the entire thickness of the aquifer & Discharge for Fully Penetrating Gravity Well refers to the volume of water extracted from an unconfined aquifer where the well reaches the entire thickness of the aquifer.
How to calculate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well?
Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well formula is defined as a dimensionless quantity that accounts for the reduction in well discharge due to partial penetration of the well screen into the aquifer, providing a correction to the discharge rate of a fully penetrating well is calculated using Correction Factor = Discharge for Partially Penetrating Well/Discharge for Fully Penetrating Gravity Well. To calculate Correction Factor for Partial Penetration given Discharge for Fully Penetrating Well, you need Discharge for Partially Penetrating Well (Qv) & Discharge for Fully Penetrating Gravity Well (Qfe). With our tool, you need to enter the respective value for Discharge for Partially Penetrating Well & Discharge for Fully Penetrating Gravity Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Correction Factor?
In this formula, Correction Factor uses Discharge for Partially Penetrating Well & Discharge for Fully Penetrating Gravity Well. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Correction Factor = Discharge for Partially Penetrating Well/((2*pi*Coefficient of Permeability*Aquifer Thickness*(Initial Piezometric Surface-Depth of Water))/(log((Radius of Influence/Radius of Well),e)))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!