Correction Factor for Industrial Service given Design Power Solution

STEP 0: Pre-Calculation Summary
Formula Used
Correction Factor for Industrial Service = Design Power of Belt Drive/Power Transmitted by Belt
Far = Pd/Pt
This formula uses 3 Variables
Variables Used
Correction Factor for Industrial Service - Correction Factor for Industrial Service is the correction factor that is used for industrial purpose.
Design Power of Belt Drive - (Measured in Watt) - Design Power of Belt Drive is defined as the power transmitted on the basis of the design.
Power Transmitted by Belt - (Measured in Watt) - Power Transmitted by Belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
STEP 1: Convert Input(s) to Base Unit
Design Power of Belt Drive: 7.41 Kilowatt --> 7410 Watt (Check conversion ​here)
Power Transmitted by Belt: 6.45 Kilowatt --> 6450 Watt (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Far = Pd/Pt --> 7410/6450
Evaluating ... ...
Far = 1.14883720930233
STEP 3: Convert Result to Output's Unit
1.14883720930233 --> No Conversion Required
FINAL ANSWER
1.14883720930233 1.148837 <-- Correction Factor for Industrial Service
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Selection of V Belts Calculators

Pitch diameter of big pulley of V Belt drive
​ LaTeX ​ Go Diameter of Big Pulley = Diameter of Small Pulley*(Speed of Smaller Pulley/Speed of Larger Pulley)
Correction Factor for Industrial Service given Design Power
​ LaTeX ​ Go Correction Factor for Industrial Service = Design Power of Belt Drive/Power Transmitted by Belt
Transmitted Power given Design Power
​ LaTeX ​ Go Power Transmitted by Belt = Design Power of Belt Drive/Correction Factor for Industrial Service
Design Power for V Belt
​ LaTeX ​ Go Design Power of Belt Drive = Correction Factor for Industrial Service*Power Transmitted by Belt

Correction Factor for Industrial Service given Design Power Formula

​LaTeX ​Go
Correction Factor for Industrial Service = Design Power of Belt Drive/Power Transmitted by Belt
Far = Pd/Pt

Define a Belt Drive?

A belt drive is a transmission system that uses a flexible strip to transfer power. The turning disk is connected by a belt drive to the electric motor. A rubber belt drive is used to transfer power from one pulley to another.

How to Calculate Correction Factor for Industrial Service given Design Power?

Correction Factor for Industrial Service given Design Power calculator uses Correction Factor for Industrial Service = Design Power of Belt Drive/Power Transmitted by Belt to calculate the Correction Factor for Industrial Service, Correction Factor for Industrial Service given Design Power formula is defined as a method to adjust the design power of a system to account for varying operational conditions, ensuring optimal performance and reliability in industrial applications. Correction Factor for Industrial Service is denoted by Far symbol.

How to calculate Correction Factor for Industrial Service given Design Power using this online calculator? To use this online calculator for Correction Factor for Industrial Service given Design Power, enter Design Power of Belt Drive (Pd) & Power Transmitted by Belt (Pt) and hit the calculate button. Here is how the Correction Factor for Industrial Service given Design Power calculation can be explained with given input values -> 1.148837 = 7410/6450.

FAQ

What is Correction Factor for Industrial Service given Design Power?
Correction Factor for Industrial Service given Design Power formula is defined as a method to adjust the design power of a system to account for varying operational conditions, ensuring optimal performance and reliability in industrial applications and is represented as Far = Pd/Pt or Correction Factor for Industrial Service = Design Power of Belt Drive/Power Transmitted by Belt. Design Power of Belt Drive is defined as the power transmitted on the basis of the design & Power Transmitted by Belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
How to calculate Correction Factor for Industrial Service given Design Power?
Correction Factor for Industrial Service given Design Power formula is defined as a method to adjust the design power of a system to account for varying operational conditions, ensuring optimal performance and reliability in industrial applications is calculated using Correction Factor for Industrial Service = Design Power of Belt Drive/Power Transmitted by Belt. To calculate Correction Factor for Industrial Service given Design Power, you need Design Power of Belt Drive (Pd) & Power Transmitted by Belt (Pt). With our tool, you need to enter the respective value for Design Power of Belt Drive & Power Transmitted by Belt and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!