Conversion Factor given Theoretical Oxygen Requirement Solution

STEP 0: Pre-Calculation Summary
Formula Used
BOD Conversion Factor = (8.34*Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration))/(Theoretical Oxygen Requirement+(1.42*Net Waste Activated Sludge))
f = (8.34*Qa*(So-S))/(O2+(1.42*Px))
This formula uses 6 Variables
Variables Used
BOD Conversion Factor - BOD Conversion Factor is the value that is multiplied in the 5 days BOD to get the value of ultimate BOD.
Average Daily Influent Flow Rate - (Measured in Cubic Meter per Second) - Average Daily Influent Flow Rate is the total discharge that comes in the reactor.
Influent Substrate Concentration - (Measured in Kilogram per Cubic Meter) - Influent Substrate Concentration refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant.
Effluent Substrate Concentration - (Measured in Kilogram per Cubic Meter) - Effluent Substrate Concentration refers to the concentration of organic matter or nutrients present in the treated wastewater (effluent) that is discharged from a wastewater treatment plant.
Theoretical Oxygen Requirement - (Measured in Kilogram per Second) - Theoretical Oxygen Requirement is the calculated amount of oxygen required to oxidize a compound to its final oxidation products.
Net Waste Activated Sludge - (Measured in Kilogram per Second) - Net Waste Activated Sludge is the amount of waste product that can be treated using the activated sludge process.
STEP 1: Convert Input(s) to Base Unit
Average Daily Influent Flow Rate: 1.2 Cubic Meter per Day --> 1.38888888888889E-05 Cubic Meter per Second (Check conversion ​here)
Influent Substrate Concentration: 25 Milligram per Liter --> 0.025 Kilogram per Cubic Meter (Check conversion ​here)
Effluent Substrate Concentration: 15 Milligram per Liter --> 0.015 Kilogram per Cubic Meter (Check conversion ​here)
Theoretical Oxygen Requirement: 2.5 Milligram per Day --> 2.89351851851852E-11 Kilogram per Second (Check conversion ​here)
Net Waste Activated Sludge: 20 Milligram per Day --> 2.31481481481481E-10 Kilogram per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = (8.34*Qa*(So-S))/(O2+(1.42*Px)) --> (8.34*1.38888888888889E-05*(0.025-0.015))/(2.89351851851852E-11+(1.42*2.31481481481481E-10))
Evaluating ... ...
f = 3238.83495145632
STEP 3: Convert Result to Output's Unit
3238.83495145632 --> No Conversion Required
FINAL ANSWER
3238.83495145632 3238.835 <-- BOD Conversion Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Theoretical Oxygen Requirement Calculators

Theoretical Oxygen requirements using Conversion Factor
​ LaTeX ​ Go Theoretical Oxygen Requirement = ((Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration)*8.34)/BOD Conversion Factor)-(1.42*Net Waste Activated Sludge)
Theoretical Oxygen Requirement for removal of Carbonaceous Organic Matter
​ LaTeX ​ Go Theoretical Oxygen Requirement = Total BOD Utilized-(1.42*Mass of Organisms Wasted)
Total Mass of BOD Utilized given Theoretical Oxygen Requirement
​ LaTeX ​ Go Total BOD Utilized = Theoretical Oxygen Requirement+(1.42*Mass of Organisms Wasted)
Mass of Organisms Wasted given Theoretical Oxygen Requirement
​ LaTeX ​ Go Mass of Organisms Wasted = (Total BOD Utilized-Theoretical Oxygen Requirement)/1.42

Conversion Factor given Theoretical Oxygen Requirement Formula

​LaTeX ​Go
BOD Conversion Factor = (8.34*Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration))/(Theoretical Oxygen Requirement+(1.42*Net Waste Activated Sludge))
f = (8.34*Qa*(So-S))/(O2+(1.42*Px))

What is Theoretical Oxygen Requirement?

The Theoretical Oxygen Requirement is the calculated amount of oxygen required to oxidize a compound to its final oxidation products.

How to Calculate Conversion Factor given Theoretical Oxygen Requirement?

Conversion Factor given Theoretical Oxygen Requirement calculator uses BOD Conversion Factor = (8.34*Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration))/(Theoretical Oxygen Requirement+(1.42*Net Waste Activated Sludge)) to calculate the BOD Conversion Factor, The Conversion Factor given Theoretical Oxygen Requirement formula is defined as the value that is required to convert 5 days BOD to ultimate BOD. BOD Conversion Factor is denoted by f symbol.

How to calculate Conversion Factor given Theoretical Oxygen Requirement using this online calculator? To use this online calculator for Conversion Factor given Theoretical Oxygen Requirement, enter Average Daily Influent Flow Rate (Qa), Influent Substrate Concentration (So), Effluent Substrate Concentration (S), Theoretical Oxygen Requirement (O2) & Net Waste Activated Sludge (Px) and hit the calculate button. Here is how the Conversion Factor given Theoretical Oxygen Requirement calculation can be explained with given input values -> 3238.835 = (8.34*1.38888888888889E-05*(0.025-0.015))/(2.89351851851852E-11+(1.42*2.31481481481481E-10)).

FAQ

What is Conversion Factor given Theoretical Oxygen Requirement?
The Conversion Factor given Theoretical Oxygen Requirement formula is defined as the value that is required to convert 5 days BOD to ultimate BOD and is represented as f = (8.34*Qa*(So-S))/(O2+(1.42*Px)) or BOD Conversion Factor = (8.34*Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration))/(Theoretical Oxygen Requirement+(1.42*Net Waste Activated Sludge)). Average Daily Influent Flow Rate is the total discharge that comes in the reactor, Influent Substrate Concentration refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant, Effluent Substrate Concentration refers to the concentration of organic matter or nutrients present in the treated wastewater (effluent) that is discharged from a wastewater treatment plant, Theoretical Oxygen Requirement is the calculated amount of oxygen required to oxidize a compound to its final oxidation products & Net Waste Activated Sludge is the amount of waste product that can be treated using the activated sludge process.
How to calculate Conversion Factor given Theoretical Oxygen Requirement?
The Conversion Factor given Theoretical Oxygen Requirement formula is defined as the value that is required to convert 5 days BOD to ultimate BOD is calculated using BOD Conversion Factor = (8.34*Average Daily Influent Flow Rate*(Influent Substrate Concentration-Effluent Substrate Concentration))/(Theoretical Oxygen Requirement+(1.42*Net Waste Activated Sludge)). To calculate Conversion Factor given Theoretical Oxygen Requirement, you need Average Daily Influent Flow Rate (Qa), Influent Substrate Concentration (So), Effluent Substrate Concentration (S), Theoretical Oxygen Requirement (O2) & Net Waste Activated Sludge (Px). With our tool, you need to enter the respective value for Average Daily Influent Flow Rate, Influent Substrate Concentration, Effluent Substrate Concentration, Theoretical Oxygen Requirement & Net Waste Activated Sludge and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!