Constant using Volume of Conductor Material (3-Phase 4-Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Constant Overhead AC = Volume of Conductor*(cos(Phase Difference))^2/(0.583)
K = V*(cos(Φ))^2/(0.583)
This formula uses 1 Functions, 3 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Constant Overhead AC - Constant Overhead AC is defined as the constant of line of a Overhead supply system.
Volume of Conductor - (Measured in Cubic Meter) - Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Phase Difference - (Measured in Radian) - Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
STEP 1: Convert Input(s) to Base Unit
Volume of Conductor: 26 Cubic Meter --> 26 Cubic Meter No Conversion Required
Phase Difference: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K = V*(cos(Φ))^2/(0.583) --> 26*(cos(0.5235987755982))^2/(0.583)
Evaluating ... ...
K = 33.4476843910806
STEP 3: Convert Result to Output's Unit
33.4476843910806 --> No Conversion Required
FINAL ANSWER
33.4476843910806 33.44768 <-- Constant Overhead AC
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Area of X-Section(3-Phase 4-Wire OS)
​ LaTeX ​ Go Area of Overhead AC Wire = 2*(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire/(((cos(Phase Difference))^2)*Line Losses*3*(Maximum Voltage Overhead AC^2))
Constant(3-Phase 4-Wire OS)
​ LaTeX ​ Go Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses*(Maximum Voltage Overhead AC^2))
Volume of Conductor Material(3-Phase 4-Wire OS)
​ LaTeX ​ Go Volume of Conductor = (3.5)*Area of Overhead AC Wire*Length of Overhead AC Wire
Line Losses(3-Phase 4-Wire OS)
​ LaTeX ​ Go Line Losses = (3)*((Current Overhead AC)^2)*Resistance Overhead AC

Constant using Volume of Conductor Material (3-Phase 4-Wire OS) Formula

​LaTeX ​Go
Constant Overhead AC = Volume of Conductor*(cos(Phase Difference))^2/(0.583)
K = V*(cos(Φ))^2/(0.583)

What is the value of maximum voltage and volume of conductor material in 3-phase 4-wire system?

The volume of conductor material required in this system is 7/12cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is vm so that r.m.s. value of voltage between them is vm/√2.

How to Calculate Constant using Volume of Conductor Material (3-Phase 4-Wire OS)?

Constant using Volume of Conductor Material (3-Phase 4-Wire OS) calculator uses Constant Overhead AC = Volume of Conductor*(cos(Phase Difference))^2/(0.583) to calculate the Constant Overhead AC, The Constant using Volume of Conductor Material (3-phase 4-wire OS) formula is defined as the total constant of a 3-phase 4-wire overhead system. it is represented by K. Constant Overhead AC is denoted by K symbol.

How to calculate Constant using Volume of Conductor Material (3-Phase 4-Wire OS) using this online calculator? To use this online calculator for Constant using Volume of Conductor Material (3-Phase 4-Wire OS), enter Volume of Conductor (V) & Phase Difference (Φ) and hit the calculate button. Here is how the Constant using Volume of Conductor Material (3-Phase 4-Wire OS) calculation can be explained with given input values -> 33.44768 = 26*(cos(0.5235987755982))^2/(0.583).

FAQ

What is Constant using Volume of Conductor Material (3-Phase 4-Wire OS)?
The Constant using Volume of Conductor Material (3-phase 4-wire OS) formula is defined as the total constant of a 3-phase 4-wire overhead system. it is represented by K and is represented as K = V*(cos(Φ))^2/(0.583) or Constant Overhead AC = Volume of Conductor*(cos(Phase Difference))^2/(0.583). Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line & Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
How to calculate Constant using Volume of Conductor Material (3-Phase 4-Wire OS)?
The Constant using Volume of Conductor Material (3-phase 4-wire OS) formula is defined as the total constant of a 3-phase 4-wire overhead system. it is represented by K is calculated using Constant Overhead AC = Volume of Conductor*(cos(Phase Difference))^2/(0.583). To calculate Constant using Volume of Conductor Material (3-Phase 4-Wire OS), you need Volume of Conductor (V) & Phase Difference (Φ). With our tool, you need to enter the respective value for Volume of Conductor & Phase Difference and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Constant Overhead AC?
In this formula, Constant Overhead AC uses Volume of Conductor & Phase Difference. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses*(Maximum Voltage Overhead AC^2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!