Constant used in Flood Discharge by Fuller's Formula Solution

STEP 0: Pre-Calculation Summary
Formula Used
Fuller's Constant = (Flood Discharge by Fuller's Formula/(((Catchment Area for Flood Discharge)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2.67*(Catchment Area for Flood Discharge)^(-0.3))))
CFL = (QFL/(((Akm)^(0.8))*(1+0.8*log(Tm,e))*(1+2.67*(Akm)^(-0.3))))
This formula uses 1 Constants, 1 Functions, 4 Variables
Constants Used
e - Napier's constant Value Taken As 2.71828182845904523536028747135266249
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Fuller's Constant - Fuller's Constant refers to an empirical coefficient used in Fuller's formula to estimate peak flood discharge, adjusted for regional hydrological conditions.
Flood Discharge by Fuller's Formula - (Measured in Cubic Meter per Second) - Flood Discharge by Fuller's Formula refers to peak discharge based on catchment area and rainfall intensity, considering regional characteristics.
Catchment Area for Flood Discharge - (Measured in Square Meter) - Catchment Area for Flood Discharge refers to an area of land where all water flows to a single stream, river, lake or even ocean, typically in km unit.
Time Period for a Flood Discharge - (Measured in Second) - Time Period for a Flood Discharge refers to number of years after which a flood is recorded.
STEP 1: Convert Input(s) to Base Unit
Flood Discharge by Fuller's Formula: 25355.77 Cubic Meter per Second --> 25355.77 Cubic Meter per Second No Conversion Required
Catchment Area for Flood Discharge: 2.4 Square Kilometer --> 2400000 Square Meter (Check conversion ​here)
Time Period for a Flood Discharge: 2.2 Year --> 69425294.4 Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
CFL = (QFL/(((Akm)^(0.8))*(1+0.8*log(Tm,e))*(1+2.67*(Akm)^(-0.3)))) --> (25355.77/(((2400000)^(0.8))*(1+0.8*log(69425294.4,e))*(1+2.67*(2400000)^(-0.3))))
Evaluating ... ...
CFL = 0.184999989027547
STEP 3: Convert Result to Output's Unit
0.184999989027547 --> No Conversion Required
FINAL ANSWER
0.184999989027547 0.185 <-- Fuller's Constant
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Fuller's Formula Calculators

Constant used in Flood Discharge by Fuller's Formula
​ LaTeX ​ Go Fuller's Constant = (Flood Discharge by Fuller's Formula/(((Catchment Area for Flood Discharge)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2.67*(Catchment Area for Flood Discharge)^(-0.3))))
Flood Discharge by Fuller's Formula
​ LaTeX ​ Go Flood Discharge by Fuller's Formula = Fuller's Constant*((Catchment Area for Flood Discharge)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2.67*(Catchment Area for Flood Discharge)^(-0.3))
Constant used in FPS Unit given Flood Discharge by Fuller's Formula
​ LaTeX ​ Go Fuller's Constant for FPS = (Flood Discharge by Fuller's Formula in FPS/(((Area of Basin)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2*(Area of Basin)^(-0.2))))
Flood Discharge in FPS Unit by Fuller's Formula
​ LaTeX ​ Go Flood Discharge by Fuller's Formula in FPS = Fuller's Constant for FPS*((Area of Basin)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2*(Area of Basin)^(-0.2))

Constant used in Flood Discharge by Fuller's Formula Formula

​LaTeX ​Go
Fuller's Constant = (Flood Discharge by Fuller's Formula/(((Catchment Area for Flood Discharge)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2.67*(Catchment Area for Flood Discharge)^(-0.3))))
CFL = (QFL/(((Akm)^(0.8))*(1+0.8*log(Tm,e))*(1+2.67*(Akm)^(-0.3))))

What is Catchment Area ?

A catchment is an area of land where water collects when it rains, often bounded by hills. As the water flows over the landscape it finds its way into streams and down into the soil, eventually feeding the river.

How to Calculate Constant used in Flood Discharge by Fuller's Formula?

Constant used in Flood Discharge by Fuller's Formula calculator uses Fuller's Constant = (Flood Discharge by Fuller's Formula/(((Catchment Area for Flood Discharge)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2.67*(Catchment Area for Flood Discharge)^(-0.3)))) to calculate the Fuller's Constant, The Constant used in Flood Discharge by Fuller's Formula is defined as an empirical coefficient used in Fuller's formula to estimate peak flood discharge, adjusted for regional hydrological conditions. Fuller's Constant is denoted by CFL symbol.

How to calculate Constant used in Flood Discharge by Fuller's Formula using this online calculator? To use this online calculator for Constant used in Flood Discharge by Fuller's Formula, enter Flood Discharge by Fuller's Formula (QFL), Catchment Area for Flood Discharge (Akm) & Time Period for a Flood Discharge (Tm) and hit the calculate button. Here is how the Constant used in Flood Discharge by Fuller's Formula calculation can be explained with given input values -> 0.185 = (25355.77/(((2400000)^(0.8))*(1+0.8*log(69425294.4,e))*(1+2.67*(2400000)^(-0.3)))).

FAQ

What is Constant used in Flood Discharge by Fuller's Formula?
The Constant used in Flood Discharge by Fuller's Formula is defined as an empirical coefficient used in Fuller's formula to estimate peak flood discharge, adjusted for regional hydrological conditions and is represented as CFL = (QFL/(((Akm)^(0.8))*(1+0.8*log(Tm,e))*(1+2.67*(Akm)^(-0.3)))) or Fuller's Constant = (Flood Discharge by Fuller's Formula/(((Catchment Area for Flood Discharge)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2.67*(Catchment Area for Flood Discharge)^(-0.3)))). Flood Discharge by Fuller's Formula refers to peak discharge based on catchment area and rainfall intensity, considering regional characteristics, Catchment Area for Flood Discharge refers to an area of land where all water flows to a single stream, river, lake or even ocean, typically in km unit & Time Period for a Flood Discharge refers to number of years after which a flood is recorded.
How to calculate Constant used in Flood Discharge by Fuller's Formula?
The Constant used in Flood Discharge by Fuller's Formula is defined as an empirical coefficient used in Fuller's formula to estimate peak flood discharge, adjusted for regional hydrological conditions is calculated using Fuller's Constant = (Flood Discharge by Fuller's Formula/(((Catchment Area for Flood Discharge)^(0.8))*(1+0.8*log(Time Period for a Flood Discharge,e))*(1+2.67*(Catchment Area for Flood Discharge)^(-0.3)))). To calculate Constant used in Flood Discharge by Fuller's Formula, you need Flood Discharge by Fuller's Formula (QFL), Catchment Area for Flood Discharge (Akm) & Time Period for a Flood Discharge (Tm). With our tool, you need to enter the respective value for Flood Discharge by Fuller's Formula, Catchment Area for Flood Discharge & Time Period for a Flood Discharge and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!