Confined Aquifer Discharge with Base 10 given Drawdown at Well Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge = (2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))
Q = (2.72*KWH*bw*Stw)/(log((Rw/r),10))
This formula uses 1 Functions, 6 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Discharge - (Measured in Cubic Meter per Second) - Discharge is the flow rate of water that is extracted from or injected into a well.
Coefficient of Permeability in Well Hydraulics - (Measured in Meter per Second) - Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Total Drawdown in Well - (Measured in Meter) - Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of Well - (Measured in Meter) - Radius of Well is defined as the distance from center of well to its outer boundary.
STEP 1: Convert Input(s) to Base Unit
Coefficient of Permeability in Well Hydraulics: 10 Centimeter per Second --> 0.1 Meter per Second (Check conversion ​here)
Aquifer Thickness: 14.15 Meter --> 14.15 Meter No Conversion Required
Total Drawdown in Well: 4.93 Meter --> 4.93 Meter No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of Well: 7.5 Meter --> 7.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = (2.72*KWH*bw*Stw)/(log((Rw/r),10)) --> (2.72*0.1*14.15*4.93)/(log((8.6/7.5),10))
Evaluating ... ...
Q = 1.12779591361904
STEP 3: Convert Result to Output's Unit
1.12779591361904 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
1.12779591361904 1.127796 Cubic Meter per Second <-- Discharge
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Aquifer Discharge Calculators

Discharge in Confined Aquifer
​ LaTeX ​ Go Discharge in Confined Aquifer = (2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e))
Discharge in Confined Aquifer given Coefficient of Transmissibility
​ LaTeX ​ Go Discharge given Coefficient of Transmissibility = (2*pi*Coefficient of Transmissibility in Enviro. Eng.*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e))
Discharge in Confined Aquifer with Base 10
​ LaTeX ​ Go Discharge = (2.72*Coefficient of Permeability*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))
Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility
​ LaTeX ​ Go Discharge in Confined Aquifer = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))

Confined Aquifer Discharge with Base 10 given Drawdown at Well Formula

​LaTeX ​Go
Discharge = (2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))
Q = (2.72*KWH*bw*Stw)/(log((Rw/r),10))

What is Confined Aquifer?

A confined aquifer is an aquifer below the land surface that is saturated with water. Layers of impermeable material are both above and below the aquifer, causing it to be under pressure so that when the aquifer is penetrated by a well, the water will rise above the top of the aquifer.

How to Calculate Confined Aquifer Discharge with Base 10 given Drawdown at Well?

Confined Aquifer Discharge with Base 10 given Drawdown at Well calculator uses Discharge = (2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)) to calculate the Discharge, The Confined Aquifer Discharge with Base 10 given Drawdown at Well formula is defined as the value of confined aquifer discharge when we have prior information of drawdown at well. Discharge is denoted by Q symbol.

How to calculate Confined Aquifer Discharge with Base 10 given Drawdown at Well using this online calculator? To use this online calculator for Confined Aquifer Discharge with Base 10 given Drawdown at Well, enter Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button. Here is how the Confined Aquifer Discharge with Base 10 given Drawdown at Well calculation can be explained with given input values -> 1.195543 = (2.72*0.1*14.15*4.93)/(log((8.6/7.5),10)).

FAQ

What is Confined Aquifer Discharge with Base 10 given Drawdown at Well?
The Confined Aquifer Discharge with Base 10 given Drawdown at Well formula is defined as the value of confined aquifer discharge when we have prior information of drawdown at well and is represented as Q = (2.72*KWH*bw*Stw)/(log((Rw/r),10)) or Discharge = (2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)). Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil, Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water, Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table & Radius of Well is defined as the distance from center of well to its outer boundary.
How to calculate Confined Aquifer Discharge with Base 10 given Drawdown at Well?
The Confined Aquifer Discharge with Base 10 given Drawdown at Well formula is defined as the value of confined aquifer discharge when we have prior information of drawdown at well is calculated using Discharge = (2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)). To calculate Confined Aquifer Discharge with Base 10 given Drawdown at Well, you need Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness (bw), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r). With our tool, you need to enter the respective value for Coefficient of Permeability in Well Hydraulics, Aquifer Thickness, Total Drawdown in Well, Radius of Influence & Radius of Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Discharge?
In this formula, Discharge uses Coefficient of Permeability in Well Hydraulics, Aquifer Thickness, Total Drawdown in Well, Radius of Influence & Radius of Well. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Discharge = (2.72*Coefficient of Permeability*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))
  • Discharge = (2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),e))
  • Discharge = (2*pi*Coefficient of Transmissibility*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))