Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))
Q = (2.72*Tw*(h2-h1))/(log((r2/r1),10))
This formula uses 1 Functions, 6 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Discharge - (Measured in Cubic Meter per Second) - Discharge is the flow rate of water that is extracted from or injected into a well.
Coefficient of Transmissibility in Enviro. Eng. - (Measured in Square Meter per Second) - Coefficient of Transmissibility in Enviro. Eng. is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Depth of Water 2 - (Measured in Meter) - Depth of water 2 means the depth of the water in 2nd well.
Depth of Water 1 - (Measured in Meter) - Depth of Water 1 is the depth of water in the 1st considered well.
Radial Distance at Observation Well 2 - (Measured in Meter) - Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Radial Distance at Observation Well 1 - (Measured in Meter) - Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
STEP 1: Convert Input(s) to Base Unit
Coefficient of Transmissibility in Enviro. Eng.: 26.9 Square Meter per Second --> 26.9 Square Meter per Second No Conversion Required
Depth of Water 2: 17.8644 Meter --> 17.8644 Meter No Conversion Required
Depth of Water 1: 17.85 Meter --> 17.85 Meter No Conversion Required
Radial Distance at Observation Well 2: 10 Meter --> 10 Meter No Conversion Required
Radial Distance at Observation Well 1: 1.07 Meter --> 1.07 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = (2.72*Tw*(h2-h1))/(log((r2/r1),10)) --> (2.72*26.9*(17.8644-17.85))/(log((10/1.07),10))
Evaluating ... ...
Q = 1.02265988766222
STEP 3: Convert Result to Output's Unit
1.02265988766222 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
1.02265988766222 1.02266 Cubic Meter per Second <-- Discharge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Aquifer Discharge Calculators

Discharge in Confined Aquifer
​ LaTeX ​ Go Discharge in Confined Aquifer = (2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e))
Discharge in Confined Aquifer given Coefficient of Transmissibility
​ LaTeX ​ Go Discharge given Coefficient of Transmissibility = (2*pi*Coefficient of Transmissibility in Enviro. Eng.*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),e))
Discharge in Confined Aquifer with Base 10
​ LaTeX ​ Go Discharge = (2.72*Coefficient of Permeability*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))
Discharge in Confined Aquifer with Base 10 given Coefficient of Transmissibility
​ LaTeX ​ Go Discharge in Confined Aquifer = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))

Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water Formula

​LaTeX ​Go
Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10))
Q = (2.72*Tw*(h2-h1))/(log((r2/r1),10))

What is Confined Aquifer?

A confined aquifer is an aquifer below the land surface that is saturated with water. Layers of impermeable material are both above and below the aquifer, causing it to be under pressure so that when the aquifer is penetrated by a well, the water will rise above the top of the aquifer.

How to Calculate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?

Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water calculator uses Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)) to calculate the Discharge, The Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water formula is defined as the value of confined aquifer discharge when we have prior information of coefficient of transmissibility and depth of water. Discharge is denoted by Q symbol.

How to calculate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water using this online calculator? To use this online calculator for Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water, enter Coefficient of Transmissibility in Enviro. Eng. (Tw), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1) and hit the calculate button. Here is how the Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water calculation can be explained with given input values -> 1.02266 = (2.72*26.9*(17.8644-17.85))/(log((10/1.07),10)).

FAQ

What is Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?
The Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water formula is defined as the value of confined aquifer discharge when we have prior information of coefficient of transmissibility and depth of water and is represented as Q = (2.72*Tw*(h2-h1))/(log((r2/r1),10)) or Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)). Coefficient of Transmissibility in Enviro. Eng. is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer, Depth of water 2 means the depth of the water in 2nd well, Depth of Water 1 is the depth of water in the 1st considered well, Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used & Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
How to calculate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water?
The Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water formula is defined as the value of confined aquifer discharge when we have prior information of coefficient of transmissibility and depth of water is calculated using Discharge = (2.72*Coefficient of Transmissibility in Enviro. Eng.*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)). To calculate Confined Aquifer Discharge given Coefficient of Transmissibility and Depth of Water, you need Coefficient of Transmissibility in Enviro. Eng. (Tw), Depth of Water 2 (h2), Depth of Water 1 (h1), Radial Distance at Observation Well 2 (r2) & Radial Distance at Observation Well 1 (r1). With our tool, you need to enter the respective value for Coefficient of Transmissibility in Enviro. Eng, Depth of Water 2, Depth of Water 1, Radial Distance at Observation Well 2 & Radial Distance at Observation Well 1 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Discharge?
In this formula, Discharge uses Coefficient of Transmissibility in Enviro. Eng, Depth of Water 2, Depth of Water 1, Radial Distance at Observation Well 2 & Radial Distance at Observation Well 1. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Discharge = (2.72*Coefficient of Permeability*Aquifer Thickness*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of Well),10))
  • Discharge = (2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),e))
  • Discharge = (2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!