Conductance of Distortionless Line Solution

STEP 0: Pre-Calculation Summary
Formula Used
Conductance = (Resistance*Capacitance)/Inductance
G = (R*C)/L
This formula uses 4 Variables
Variables Used
Conductance - (Measured in Siemens) - Conductance refers to the loss of electrical energy due to the inherent resistance of the conductors or the dielectric material between the conductors.
Resistance - (Measured in Ohm) - Resistance is the component of the total impedance that represents the opposition to the flow of electrical current due to the resistive properties of the transmission line itself.
Capacitance - (Measured in Farad) - Capacitance is the ratio of the amount of electric charge stored on a conductor to a difference in electric potential.
Inductance - (Measured in Henry) - Inductance refers to the property of an antenna element or a complete antenna structure to store electromagnetic energy in the form of a magnetic field.
STEP 1: Convert Input(s) to Base Unit
Resistance: 12.75 Ohm --> 12.75 Ohm No Conversion Required
Capacitance: 13 Microfarad --> 1.3E-05 Farad (Check conversion ​here)
Inductance: 5.1 Millihenry --> 0.0051 Henry (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
G = (R*C)/L --> (12.75*1.3E-05)/0.0051
Evaluating ... ...
G = 0.0325
STEP 3: Convert Result to Output's Unit
0.0325 Siemens -->0.0325 Mho (Check conversion ​here)
FINAL ANSWER
0.0325 Mho <-- Conductance
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Pranav Simha R
BMS College of Engineering (BMSCE), Bangalore,India
Pranav Simha R has created this Calculator and 10+ more calculators!
Verifier Image
Verified by Rachita C
BMS College Of Engineering (BMSCE), Banglore
Rachita C has verified this Calculator and 50+ more calculators!

Transmission Line Characteristics Calculators

Resistance at Second Temperature
​ LaTeX ​ Go Final Resistance = Initial Resistance*((Temperature Coefficient+Final Temperature)/(Temperature Coefficient+Initial Temperature))
Length of Wound Conductor
​ LaTeX ​ Go Length of Wound Conductor = sqrt(1+(pi/Relative Pitch of Wound Conductor)^2)
Relative Pitch of Wound Conductor
​ LaTeX ​ Go Relative Pitch of Wound Conductor = (Length of Spiral/(2*Radius of Layer))
Wavelength of Line
​ LaTeX ​ Go Wavelength = (2*pi)/Propagation Constant

Conductance of Distortionless Line Formula

​LaTeX ​Go
Conductance = (Resistance*Capacitance)/Inductance
G = (R*C)/L

What is the condition for distortion less line?

The condition for a distortionless line is defined by the preservation of the waveform shape and integrity of an electrical signal as it propagates through the transmission line. In other words, a distortionless line does not alter the amplitude, phase, or frequency content of the transmitted signal.

How to Calculate Conductance of Distortionless Line?

Conductance of Distortionless Line calculator uses Conductance = (Resistance*Capacitance)/Inductance to calculate the Conductance, Conductance of Distortionless Line refers to the measure of the ease with which electric current can flow through the line. It is the reciprocal of the resistance and represents the real part of the admittance of the line. Conductance is denoted by G symbol.

How to calculate Conductance of Distortionless Line using this online calculator? To use this online calculator for Conductance of Distortionless Line, enter Resistance (R), Capacitance (C) & Inductance (L) and hit the calculate button. Here is how the Conductance of Distortionless Line calculation can be explained with given input values -> 0.0325 = (12.75*1.3E-05)/0.0051.

FAQ

What is Conductance of Distortionless Line?
Conductance of Distortionless Line refers to the measure of the ease with which electric current can flow through the line. It is the reciprocal of the resistance and represents the real part of the admittance of the line and is represented as G = (R*C)/L or Conductance = (Resistance*Capacitance)/Inductance. Resistance is the component of the total impedance that represents the opposition to the flow of electrical current due to the resistive properties of the transmission line itself, Capacitance is the ratio of the amount of electric charge stored on a conductor to a difference in electric potential & Inductance refers to the property of an antenna element or a complete antenna structure to store electromagnetic energy in the form of a magnetic field.
How to calculate Conductance of Distortionless Line?
Conductance of Distortionless Line refers to the measure of the ease with which electric current can flow through the line. It is the reciprocal of the resistance and represents the real part of the admittance of the line is calculated using Conductance = (Resistance*Capacitance)/Inductance. To calculate Conductance of Distortionless Line, you need Resistance (R), Capacitance (C) & Inductance (L). With our tool, you need to enter the respective value for Resistance, Capacitance & Inductance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!