Concentration of Solids in Effluent given Wasting Rate from Return Line Solution

STEP 0: Pre-Calculation Summary
Formula Used
Solid Concentration in Effluent = (Reactor Volume*MLSS/(Mean Cell Residence Time*Effluent Flow Rate))-(WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/Effluent Flow Rate)
Xe = (V*X/(θc*Qe))-(Qw'*Xr/Qe)
This formula uses 7 Variables
Variables Used
Solid Concentration in Effluent - (Measured in Kilogram per Cubic Meter) - Solid Concentration in Effluent is the total amount of solids that are present in the effluent.
Reactor Volume - (Measured in Cubic Meter) - Reactor Volume refers to the physical volume of a reactor used in chemical processes.
MLSS - (Measured in Kilogram per Cubic Meter) - MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics).
Mean Cell Residence Time - (Measured in Second) - Mean Cell Residence Time is the average time that the sludge remains in the reactor.
Effluent Flow Rate - (Measured in Cubic Meter per Second) - Effluent Flow Rate is the total quantity of the flow of sewage from the secondary clarifier.
WAS Pumping Rate from Return Line - (Measured in Cubic Meter per Second) - WAS Pumping Rate from Return Line is the flow rate of waste sludge from the return line.
Sludge Concentration in Return Line - (Measured in Kilogram per Cubic Meter) - Sludge Concentration in Return Line refers to the concentration of suspended solids in the sludge that is being pumped back from the secondary clarifier to the aeration tank.
STEP 1: Convert Input(s) to Base Unit
Reactor Volume: 1000 Cubic Meter --> 1000 Cubic Meter No Conversion Required
MLSS: 1200 Milligram per Liter --> 1.2 Kilogram per Cubic Meter (Check conversion ​here)
Mean Cell Residence Time: 7 Day --> 604800 Second (Check conversion ​here)
Effluent Flow Rate: 1523.81 Cubic Meter per Day --> 0.0176366898148148 Cubic Meter per Second (Check conversion ​here)
WAS Pumping Rate from Return Line: 400 Cubic Meter per Day --> 0.00462962962962963 Cubic Meter per Second (Check conversion ​here)
Sludge Concentration in Return Line: 200 Milligram per Liter --> 0.2 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Xe = (V*X/(θc*Qe))-(Qw'*Xr/Qe) --> (1000*1.2/(604800*0.0176366898148148))-(0.00462962962962963*0.2/0.0176366898148148)
Evaluating ... ...
Xe = 0.0599999812500059
STEP 3: Convert Result to Output's Unit
0.0599999812500059 Kilogram per Cubic Meter -->59.9999812500059 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
59.9999812500059 59.99998 Milligram per Liter <-- Solid Concentration in Effluent
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Concentration of Solids Calculators

Concentration of Sludge in Return Line given Wasting Rate from Return Line
​ LaTeX ​ Go Sludge Concentration in Return Line = (Reactor Volume*MLSS/(Mean Cell Residence Time*WAS Pumping Rate from Return Line))-(Effluent Flow Rate*Solid Concentration in Effluent/WAS Pumping Rate from Return Line)
Concentration of Solids in Effluent given Wasting Rate from Return Line
​ LaTeX ​ Go Solid Concentration in Effluent = (Reactor Volume*MLSS/(Mean Cell Residence Time*Effluent Flow Rate))-(WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/Effluent Flow Rate)
Concentration of Sludge in Return Line given RAS Pumping Rate from Aeration Tank
​ LaTeX ​ Go Sludge Concentration in Return Line = MLSS*(Average Daily Influent Flow Rate+Return Activated Sludge)/(Return Activated Sludge+WAS Pumping Rate from Return Line)

Concentration of Solids in Effluent given Wasting Rate from Return Line Formula

​LaTeX ​Go
Solid Concentration in Effluent = (Reactor Volume*MLSS/(Mean Cell Residence Time*Effluent Flow Rate))-(WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/Effluent Flow Rate)
Xe = (V*X/(θc*Qe))-(Qw'*Xr/Qe)

What is Wasting Rate?

Wasting Rate from return line is the time required to waste sludge from the return sludge line because return activated sludge is more concentrated and requires smaller waste sludge pumps.

How to Calculate Concentration of Solids in Effluent given Wasting Rate from Return Line?

Concentration of Solids in Effluent given Wasting Rate from Return Line calculator uses Solid Concentration in Effluent = (Reactor Volume*MLSS/(Mean Cell Residence Time*Effluent Flow Rate))-(WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/Effluent Flow Rate) to calculate the Solid Concentration in Effluent, The Concentration of Solids in Effluent given Wasting Rate from Return Line formula is defined as the amount of solids that are present in the sewage after the treatment has been done. Solid Concentration in Effluent is denoted by Xe symbol.

How to calculate Concentration of Solids in Effluent given Wasting Rate from Return Line using this online calculator? To use this online calculator for Concentration of Solids in Effluent given Wasting Rate from Return Line, enter Reactor Volume (V), MLSS (X), Mean Cell Residence Time c), Effluent Flow Rate (Qe), WAS Pumping Rate from Return Line (Qw') & Sludge Concentration in Return Line (Xr) and hit the calculate button. Here is how the Concentration of Solids in Effluent given Wasting Rate from Return Line calculation can be explained with given input values -> 59999.98 = (1000*1.2/(604800*0.0176366898148148))-(0.00462962962962963*0.2/0.0176366898148148).

FAQ

What is Concentration of Solids in Effluent given Wasting Rate from Return Line?
The Concentration of Solids in Effluent given Wasting Rate from Return Line formula is defined as the amount of solids that are present in the sewage after the treatment has been done and is represented as Xe = (V*X/(θc*Qe))-(Qw'*Xr/Qe) or Solid Concentration in Effluent = (Reactor Volume*MLSS/(Mean Cell Residence Time*Effluent Flow Rate))-(WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/Effluent Flow Rate). Reactor Volume refers to the physical volume of a reactor used in chemical processes, MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics), Mean Cell Residence Time is the average time that the sludge remains in the reactor, Effluent Flow Rate is the total quantity of the flow of sewage from the secondary clarifier, WAS Pumping Rate from Return Line is the flow rate of waste sludge from the return line & Sludge Concentration in Return Line refers to the concentration of suspended solids in the sludge that is being pumped back from the secondary clarifier to the aeration tank.
How to calculate Concentration of Solids in Effluent given Wasting Rate from Return Line?
The Concentration of Solids in Effluent given Wasting Rate from Return Line formula is defined as the amount of solids that are present in the sewage after the treatment has been done is calculated using Solid Concentration in Effluent = (Reactor Volume*MLSS/(Mean Cell Residence Time*Effluent Flow Rate))-(WAS Pumping Rate from Return Line*Sludge Concentration in Return Line/Effluent Flow Rate). To calculate Concentration of Solids in Effluent given Wasting Rate from Return Line, you need Reactor Volume (V), MLSS (X), Mean Cell Residence Time c), Effluent Flow Rate (Qe), WAS Pumping Rate from Return Line (Qw') & Sludge Concentration in Return Line (Xr). With our tool, you need to enter the respective value for Reactor Volume, MLSS, Mean Cell Residence Time, Effluent Flow Rate, WAS Pumping Rate from Return Line & Sludge Concentration in Return Line and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!