Coefficient of Transmissibility given Confined Aquifer Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))
Tenvi = Q/((2*pi*st)/(log((Rw/r),e)))
This formula uses 2 Constants, 1 Functions, 5 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
e - Napier's constant Value Taken As 2.71828182845904523536028747135266249
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Coefficient of Transmissibility - (Measured in Square Meter per Second) - Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the flow rate of water that is extracted from or injected into a well.
Total Drawdown - (Measured in Meter) - The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of Well - (Measured in Meter) - Radius of Well is defined as the distance from center of well to its outer boundary.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Total Drawdown: 0.83 Meter --> 0.83 Meter No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of Well: 7.5 Meter --> 7.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Tenvi = Q/((2*pi*st)/(log((Rw/r),e))) --> 1.01/((2*pi*0.83)/(log((8.6/7.5),e)))
Evaluating ... ...
Tenvi = 1.41510762430351
STEP 3: Convert Result to Output's Unit
1.41510762430351 Square Meter per Second --> No Conversion Required
FINAL ANSWER
1.41510762430351 1.415108 Square Meter per Second <-- Coefficient of Transmissibility
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Coefficient of Transmissibility Calculators

Coefficient of Transmissibility given Depth of Water in Two Wells
​ LaTeX ​ Go Coefficient of Transmissibility = Discharge/((2.72*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Well 1),10)))
Coefficient of Transmissibility given Confined Aquifer Discharge
​ LaTeX ​ Go Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))
Coefficient of Transmissibility given Discharge in Confined Aquifer with Base 10
​ LaTeX ​ Go Coefficient of Transmissibility = Discharge/((2.72*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of Well),10)))

Coefficient of Transmissibility given Confined Aquifer Discharge Formula

​LaTeX ​Go
Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))
Tenvi = Q/((2*pi*st)/(log((Rw/r),e)))

What is Coefficient of Transmissibility?

The coefficient of transmissibility. is defined as the rate of flow of water. in gallons per day through a vertical. strip of the aquifer 1 ft wide and ex- tending the full saturated thickness.

How to Calculate Coefficient of Transmissibility given Confined Aquifer Discharge?

Coefficient of Transmissibility given Confined Aquifer Discharge calculator uses Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))) to calculate the Coefficient of Transmissibility, The Coefficient of Transmissibility given Confined Aquifer Discharge formula is defined as the value of coefficient of transmissibility when we have prior information of confined aquifer discharge. Coefficient of Transmissibility is denoted by Tenvi symbol.

How to calculate Coefficient of Transmissibility given Confined Aquifer Discharge using this online calculator? To use this online calculator for Coefficient of Transmissibility given Confined Aquifer Discharge, enter Discharge (Q), Total Drawdown (st), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button. Here is how the Coefficient of Transmissibility given Confined Aquifer Discharge calculation can be explained with given input values -> 1.415108 = 1.01/((2*pi*0.83)/(log((8.6/7.5),e))).

FAQ

What is Coefficient of Transmissibility given Confined Aquifer Discharge?
The Coefficient of Transmissibility given Confined Aquifer Discharge formula is defined as the value of coefficient of transmissibility when we have prior information of confined aquifer discharge and is represented as Tenvi = Q/((2*pi*st)/(log((Rw/r),e))) or Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))). Discharge is the flow rate of water that is extracted from or injected into a well, The Total Drawdown is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table & Radius of Well is defined as the distance from center of well to its outer boundary.
How to calculate Coefficient of Transmissibility given Confined Aquifer Discharge?
The Coefficient of Transmissibility given Confined Aquifer Discharge formula is defined as the value of coefficient of transmissibility when we have prior information of confined aquifer discharge is calculated using Coefficient of Transmissibility = Discharge/((2*pi*Total Drawdown)/(log((Radius of Influence/Radius of Well),e))). To calculate Coefficient of Transmissibility given Confined Aquifer Discharge, you need Discharge (Q), Total Drawdown (st), Radius of Influence (Rw) & Radius of Well (r). With our tool, you need to enter the respective value for Discharge, Total Drawdown, Radius of Influence & Radius of Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Coefficient of Transmissibility?
In this formula, Coefficient of Transmissibility uses Discharge, Total Drawdown, Radius of Influence & Radius of Well. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Coefficient of Transmissibility = Discharge/((2.72*(Aquifer Thickness-Depth of Water in Well))/(log((Radius of Influence/Radius of Well),10)))
  • Coefficient of Transmissibility = Discharge/((2.72*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Well 1),10)))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!