Coefficient of Runoff when Peak Value is Considered Solution

STEP 0: Pre-Calculation Summary
Formula Used
Runoff Coefficient = Peak Discharge/(Drainage Area*Intensity of Rainfall)
Cr = Qp/(AD*i)
This formula uses 4 Variables
Variables Used
Runoff Coefficient - Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received.
Peak Discharge - (Measured in Cubic Meter per Second) - Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Drainage Area - (Measured in Square Meter) - Drainage Area is the total surface area, where the water from rain which is not absorbed into the ground flows over the ground surface, back into streams, to finally reach that point.
Intensity of Rainfall - (Measured in Meter per Second) - Intensity of Rainfall is the ratio of the total amount of rain (rainfall depth) falling during a given period to the duration of the period.
STEP 1: Convert Input(s) to Base Unit
Peak Discharge: 4 Cubic Meter per Second --> 4 Cubic Meter per Second No Conversion Required
Drainage Area: 18 Square Kilometer --> 18000000 Square Meter (Check conversion ​here)
Intensity of Rainfall: 1.6 Millimeter per Hour --> 4.44444444444444E-07 Meter per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cr = Qp/(AD*i) --> 4/(18000000*4.44444444444444E-07)
Evaluating ... ...
Cr = 0.500000000000001
STEP 3: Convert Result to Output's Unit
0.500000000000001 --> No Conversion Required
FINAL ANSWER
0.500000000000001 0.5 <-- Runoff Coefficient
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Rational Method to Estimate the Flood Peak Calculators

Intensity of Rainfall when Peak Discharge is Considered
​ LaTeX ​ Go Intensity of Rainfall = Peak Discharge/(Runoff Coefficient*Drainage Area)
Coefficient of Runoff when Peak Value is Considered
​ LaTeX ​ Go Runoff Coefficient = Peak Discharge/(Drainage Area*Intensity of Rainfall)
Drainage Area when Peak Discharge is Considered
​ LaTeX ​ Go Drainage Area = Peak Discharge/(Intensity of Rainfall*Runoff Coefficient)
Value of Peak Discharge
​ LaTeX ​ Go Peak Discharge = Runoff Coefficient*Drainage Area*Intensity of Rainfall

Coefficient of Runoff when Peak Value is Considered Formula

​LaTeX ​Go
Runoff Coefficient = Peak Discharge/(Drainage Area*Intensity of Rainfall)
Cr = Qp/(AD*i)

What is Surface Runoff & Drainage Area?

Surface runoff is water, from rain, snowmelt, or other sources, that flows over the land surface, and is a major component of the water cycle. Runoff that occurs on surfaces before reaching a channel is also called overland flow. A land area which produces runoff draining to a common point is called a watershed.
A Drainage area is the total surface area, upstream of a point on a stream, where the water from rain, snowmelt, or irrigation which is not absorbed into the ground flows over the ground surface, back into streams, to finally reach that point.

What is Peak Discharge & explain use of Runoff Coefficient?

The maximum rate of discharge during the period of runoff caused by a storm is called a peak flow. The information about peak flows and associated volume of runoff during various floods that have been observed in the past can be compiled by the analysis of the observed discharge data and runoff hydrographs.
Runoff coefficient is a dimensionless factor that is used to convert the rainfall amounts to runoff. It represents the integrated effect of catchment losses and hence depends upon the nature of the land surface, slope, degree of saturation, and rainfall intensity. It is a larger value for areas with low infiltration and high runoff (pavement, steep gradient), and lower for permeable, well-vegetated areas (forest, flat land).

How to Calculate Coefficient of Runoff when Peak Value is Considered?

Coefficient of Runoff when Peak Value is Considered calculator uses Runoff Coefficient = Peak Discharge/(Drainage Area*Intensity of Rainfall) to calculate the Runoff Coefficient, The Coefficient of Runoff when Peak Value is Considered formula is defined as the dimensionless coefficient relating the amount of runoff to the amount of precipitation received. Runoff Coefficient is denoted by Cr symbol.

How to calculate Coefficient of Runoff when Peak Value is Considered using this online calculator? To use this online calculator for Coefficient of Runoff when Peak Value is Considered, enter Peak Discharge (Qp), Drainage Area (AD) & Intensity of Rainfall (i) and hit the calculate button. Here is how the Coefficient of Runoff when Peak Value is Considered calculation can be explained with given input values -> 0.5 = 4/(18000000*4.44444444444444E-07).

FAQ

What is Coefficient of Runoff when Peak Value is Considered?
The Coefficient of Runoff when Peak Value is Considered formula is defined as the dimensionless coefficient relating the amount of runoff to the amount of precipitation received and is represented as Cr = Qp/(AD*i) or Runoff Coefficient = Peak Discharge/(Drainage Area*Intensity of Rainfall). Peak Discharge is the maximum volume flow rate passing a particular location during an event, Drainage Area is the total surface area, where the water from rain which is not absorbed into the ground flows over the ground surface, back into streams, to finally reach that point & Intensity of Rainfall is the ratio of the total amount of rain (rainfall depth) falling during a given period to the duration of the period.
How to calculate Coefficient of Runoff when Peak Value is Considered?
The Coefficient of Runoff when Peak Value is Considered formula is defined as the dimensionless coefficient relating the amount of runoff to the amount of precipitation received is calculated using Runoff Coefficient = Peak Discharge/(Drainage Area*Intensity of Rainfall). To calculate Coefficient of Runoff when Peak Value is Considered, you need Peak Discharge (Qp), Drainage Area (AD) & Intensity of Rainfall (i). With our tool, you need to enter the respective value for Peak Discharge, Drainage Area & Intensity of Rainfall and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Runoff Coefficient?
In this formula, Runoff Coefficient uses Peak Discharge, Drainage Area & Intensity of Rainfall. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Runoff Coefficient = Peak Discharge/((1/3.6)*Mean Intensity of Precipitation*Drainage Area)