Coefficient of Permeability given Confined Aquifer Discharge with Base 10 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)))
KWH = Q/((2.72*bw*Stw)/(log((Rw/r),10)))
This formula uses 1 Functions, 6 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Coefficient of Permeability in Well Hydraulics - (Measured in Meter per Second) - Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the flow rate of water that is extracted from or injected into a well.
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
Total Drawdown in Well - (Measured in Meter) - Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of Well - (Measured in Meter) - Radius of Well is defined as the distance from center of well to its outer boundary.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Aquifer Thickness: 14.15 Meter --> 14.15 Meter No Conversion Required
Total Drawdown in Well: 4.93 Meter --> 4.93 Meter No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of Well: 7.5 Meter --> 7.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KWH = Q/((2.72*bw*Stw)/(log((Rw/r),10))) --> 1.01/((2.72*14.15*4.93)/(log((8.6/7.5),10)))
Evaluating ... ...
KWH = 0.0895552101052537
STEP 3: Convert Result to Output's Unit
0.0895552101052537 Meter per Second -->8.95552101052537 Centimeter per Second (Check conversion ​here)
FINAL ANSWER
8.95552101052537 8.955521 Centimeter per Second <-- Coefficient of Permeability in Well Hydraulics
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Coefficient of Permeability Calculators

Coefficient of Permeability given Depth of Water in Two Wells
​ LaTeX ​ Go Coefficient of Permeability = Discharge/((2.72*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)))
Coefficient of Permeability given Confined Aquifer Discharge
​ LaTeX ​ Go Coefficient of Permeability in Well Hydraulics = Discharge/((2*pi*Aquifer Thickness*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))
Coefficient of Permeability given Confined Aquifer Discharge with Base 10
​ LaTeX ​ Go Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)))

Coefficient of Permeability given Confined Aquifer Discharge with Base 10 Formula

​LaTeX ​Go
Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10)))
KWH = Q/((2.72*bw*Stw)/(log((Rw/r),10)))

What is Coefficient of Permeability?

The coefficient of permeability of a soil describes how easily a liquid will move through a soil. It is also commonly referred to as the hydraulic conductivity of a soil.

How to Calculate Coefficient of Permeability given Confined Aquifer Discharge with Base 10?

Coefficient of Permeability given Confined Aquifer Discharge with Base 10 calculator uses Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))) to calculate the Coefficient of Permeability in Well Hydraulics, The Coefficient of Permeability given Confined Aquifer Discharge with Base 10 formula is defined as the value of coefficient of permeability with base 10, when we have prior information of confined aquifer discharge. Coefficient of Permeability in Well Hydraulics is denoted by KWH symbol.

How to calculate Coefficient of Permeability given Confined Aquifer Discharge with Base 10 using this online calculator? To use this online calculator for Coefficient of Permeability given Confined Aquifer Discharge with Base 10, enter Discharge (Q), Aquifer Thickness (bw), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r) and hit the calculate button. Here is how the Coefficient of Permeability given Confined Aquifer Discharge with Base 10 calculation can be explained with given input values -> 844.8041 = 1.01/((2.72*14.15*4.93)/(log((8.6/7.5),10))).

FAQ

What is Coefficient of Permeability given Confined Aquifer Discharge with Base 10?
The Coefficient of Permeability given Confined Aquifer Discharge with Base 10 formula is defined as the value of coefficient of permeability with base 10, when we have prior information of confined aquifer discharge and is represented as KWH = Q/((2.72*bw*Stw)/(log((Rw/r),10))) or Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))). Discharge is the flow rate of water that is extracted from or injected into a well, Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water, Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table & Radius of Well is defined as the distance from center of well to its outer boundary.
How to calculate Coefficient of Permeability given Confined Aquifer Discharge with Base 10?
The Coefficient of Permeability given Confined Aquifer Discharge with Base 10 formula is defined as the value of coefficient of permeability with base 10, when we have prior information of confined aquifer discharge is calculated using Coefficient of Permeability in Well Hydraulics = Discharge/((2.72*Aquifer Thickness*Total Drawdown in Well)/(log((Radius of Influence/Radius of Well),10))). To calculate Coefficient of Permeability given Confined Aquifer Discharge with Base 10, you need Discharge (Q), Aquifer Thickness (bw), Total Drawdown in Well (Stw), Radius of Influence (Rw) & Radius of Well (r). With our tool, you need to enter the respective value for Discharge, Aquifer Thickness, Total Drawdown in Well, Radius of Influence & Radius of Well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Coefficient of Permeability in Well Hydraulics?
In this formula, Coefficient of Permeability in Well Hydraulics uses Discharge, Aquifer Thickness, Total Drawdown in Well, Radius of Influence & Radius of Well. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Coefficient of Permeability in Well Hydraulics = Discharge/((2*pi*Aquifer Thickness*Total Drawdown)/(log((Radius of Influence/Radius of Well),e)))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!