How to Calculate Coefficient of Discharge given Time required to Lower Liquid for Triangular Notch?
Coefficient of Discharge given Time required to Lower Liquid for Triangular Notch calculator uses Coefficient of Discharge = (((2/3)*Cross-Sectional Area of Reservoir)/((8/15)*Time Interval*sqrt(2*Acceleration due to Gravity)*tan(Theta/2)))*((1/Head on Downstream of Weir^(3/2))-(1/Head on Upstream of Weir^(3/2))) to calculate the Coefficient of Discharge, The Coefficient of Discharge given Time required to Lower Liquid for Triangular Notch is ratio of actual discharge to theoretical discharge, i.e., ratio of mass flow rate at discharge end. Coefficient of Discharge is denoted by Cd symbol.
How to calculate Coefficient of Discharge given Time required to Lower Liquid for Triangular Notch using this online calculator? To use this online calculator for Coefficient of Discharge given Time required to Lower Liquid for Triangular Notch, enter Cross-Sectional Area of Reservoir (AR), Time Interval (Δt), Acceleration due to Gravity (g), Theta (θ), Head on Downstream of Weir (h2) & Head on Upstream of Weir (HUpstream) and hit the calculate button. Here is how the Coefficient of Discharge given Time required to Lower Liquid for Triangular Notch calculation can be explained with given input values -> 0.610084 = (((2/3)*13)/((8/15)*1.25*sqrt(2*9.8)*tan(0.5235987755982/2)))*((1/5.1^(3/2))-(1/10.1^(3/2))).