Coefficient of Discharge given Time of Emptying Circular Horizontal Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
Coefficient of Discharge = (4*Length*((((2*Radius)-Final Height of Liquid)^(3/2))-((2*Radius)-Initial Height of Liquid)^(3/2)))/(3*Total Time Taken*Area of Orifice*(sqrt(2*9.81)))
Cd = (4*L*((((2*r1)-Hf)^(3/2))-((2*r1)-Hi)^(3/2)))/(3*ttotal*a*(sqrt(2*9.81)))
This formula uses 1 Functions, 7 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Coefficient of Discharge - The Coefficient of Discharge or efflux coefficient is the ratio of the actual discharge to the theoretical discharge.
Length - (Measured in Meter) - Length is the measurement or extent of something from end to end.
Radius - (Measured in Meter) - Radius is a radial line from the focus to any point of a curve.
Final Height of Liquid - (Measured in Meter) - The Final height of liquid is a variable from the tank emptying through an orifice at its bottom.
Initial Height of Liquid - (Measured in Meter) - The Initial height of liquid is a variable from the tank emptying through an orifice at its bottom.
Total Time Taken - (Measured in Second) - Total Time Taken is the total time taken by the body to cover that space.
Area of Orifice - (Measured in Square Meter) - The Area of Orifice is often a pipe or tube of varying cross-sectional area, and it can be used to direct or modify the flow of a fluid (liquid or gas).
STEP 1: Convert Input(s) to Base Unit
Length: 31 Meter --> 31 Meter No Conversion Required
Radius: 21 Meter --> 21 Meter No Conversion Required
Final Height of Liquid: 20.1 Meter --> 20.1 Meter No Conversion Required
Initial Height of Liquid: 24 Meter --> 24 Meter No Conversion Required
Total Time Taken: 30 Second --> 30 Second No Conversion Required
Area of Orifice: 9.1 Square Meter --> 9.1 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cd = (4*L*((((2*r1)-Hf)^(3/2))-((2*r1)-Hi)^(3/2)))/(3*ttotal*a*(sqrt(2*9.81))) --> (4*31*((((2*21)-20.1)^(3/2))-((2*21)-24)^(3/2)))/(3*30*9.1*(sqrt(2*9.81)))
Evaluating ... ...
Cd = 0.892775714439483
STEP 3: Convert Result to Output's Unit
0.892775714439483 --> No Conversion Required
FINAL ANSWER
0.892775714439483 0.892776 <-- Coefficient of Discharge
(Calculation completed in 00.011 seconds)

Credits

Creator Image
Created by Maiarutselvan V
PSG College of Technology (PSGCT), Coimbatore
Maiarutselvan V has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Vinay Mishra
Indian Institute for Aeronautical Engineering and Information Technology (IIAEIT), Pune
Vinay Mishra has verified this Calculator and 100+ more calculators!

Flow Rate Calculators

Coefficient of Discharge given Time of Emptying Hemispherical Tank
​ LaTeX ​ Go Coefficient of Discharge = (pi*(((4/3)*Hemispherical Tank Radius*((Initial Height of Liquid^(3/2))-(Final Height of Liquid^(3/2))))-((2/5)*((Initial Height of Liquid^(5/2))-(Final Height of Liquid)^(5/2)))))/(Total Time Taken*Area of Orifice*(sqrt(2*9.81)))
Coefficient of Discharge given Time for Emptying Tank
​ LaTeX ​ Go Coefficient of Discharge = (2*Area of Tank*((sqrt(Initial Height of Liquid))-(sqrt(Final Height of Liquid))))/(Total Time Taken*Area of Orifice*sqrt(2*9.81))
Coefficient of discharge for area and velocity
​ LaTeX ​ Go Coefficient of Discharge = (Actual Velocity*Actual Area)/(Theoretical Velocity*Theoretical Area)
Coefficient of discharge
​ LaTeX ​ Go Coefficient of Discharge = Actual Discharge/Theoretical Discharge

Coefficient of Discharge given Time of Emptying Circular Horizontal Tank Formula

​LaTeX ​Go
Coefficient of Discharge = (4*Length*((((2*Radius)-Final Height of Liquid)^(3/2))-((2*Radius)-Initial Height of Liquid)^(3/2)))/(3*Total Time Taken*Area of Orifice*(sqrt(2*9.81)))
Cd = (4*L*((((2*r1)-Hf)^(3/2))-((2*r1)-Hi)^(3/2)))/(3*ttotal*a*(sqrt(2*9.81)))

What is coefficient of discharge?

The coefficient of discharge is defined as the ratio of the actual discharge from an orifice to the theoretical discharge from the orifice.

What is an orifice?

The orifice is defined as the small opening on the side or bottom of a tank through which any kind of fluid is flowing. The opening can be circular, triangular, or rectangular in cross-section and they are named on the basis of shape accordingly.

How to Calculate Coefficient of Discharge given Time of Emptying Circular Horizontal Tank?

Coefficient of Discharge given Time of Emptying Circular Horizontal Tank calculator uses Coefficient of Discharge = (4*Length*((((2*Radius)-Final Height of Liquid)^(3/2))-((2*Radius)-Initial Height of Liquid)^(3/2)))/(3*Total Time Taken*Area of Orifice*(sqrt(2*9.81))) to calculate the Coefficient of Discharge, The Coefficient of Discharge given Time of Emptying Circular Horizontal Tank formula is known while considering a circular horizontal tank of length L and radius R, containing liquid up to a height of H1. Coefficient of Discharge is denoted by Cd symbol.

How to calculate Coefficient of Discharge given Time of Emptying Circular Horizontal Tank using this online calculator? To use this online calculator for Coefficient of Discharge given Time of Emptying Circular Horizontal Tank, enter Length (L), Radius (r1), Final Height of Liquid (Hf), Initial Height of Liquid (Hi), Total Time Taken (ttotal) & Area of Orifice (a) and hit the calculate button. Here is how the Coefficient of Discharge given Time of Emptying Circular Horizontal Tank calculation can be explained with given input values -> 0.26326 = (4*31*((((2*21)-20.1)^(3/2))-((2*21)-24)^(3/2)))/(3*30*9.1*(sqrt(2*9.81))).

FAQ

What is Coefficient of Discharge given Time of Emptying Circular Horizontal Tank?
The Coefficient of Discharge given Time of Emptying Circular Horizontal Tank formula is known while considering a circular horizontal tank of length L and radius R, containing liquid up to a height of H1 and is represented as Cd = (4*L*((((2*r1)-Hf)^(3/2))-((2*r1)-Hi)^(3/2)))/(3*ttotal*a*(sqrt(2*9.81))) or Coefficient of Discharge = (4*Length*((((2*Radius)-Final Height of Liquid)^(3/2))-((2*Radius)-Initial Height of Liquid)^(3/2)))/(3*Total Time Taken*Area of Orifice*(sqrt(2*9.81))). Length is the measurement or extent of something from end to end, Radius is a radial line from the focus to any point of a curve, The Final height of liquid is a variable from the tank emptying through an orifice at its bottom, The Initial height of liquid is a variable from the tank emptying through an orifice at its bottom, Total Time Taken is the total time taken by the body to cover that space & The Area of Orifice is often a pipe or tube of varying cross-sectional area, and it can be used to direct or modify the flow of a fluid (liquid or gas).
How to calculate Coefficient of Discharge given Time of Emptying Circular Horizontal Tank?
The Coefficient of Discharge given Time of Emptying Circular Horizontal Tank formula is known while considering a circular horizontal tank of length L and radius R, containing liquid up to a height of H1 is calculated using Coefficient of Discharge = (4*Length*((((2*Radius)-Final Height of Liquid)^(3/2))-((2*Radius)-Initial Height of Liquid)^(3/2)))/(3*Total Time Taken*Area of Orifice*(sqrt(2*9.81))). To calculate Coefficient of Discharge given Time of Emptying Circular Horizontal Tank, you need Length (L), Radius (r1), Final Height of Liquid (Hf), Initial Height of Liquid (Hi), Total Time Taken (ttotal) & Area of Orifice (a). With our tool, you need to enter the respective value for Length, Radius, Final Height of Liquid, Initial Height of Liquid, Total Time Taken & Area of Orifice and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Coefficient of Discharge?
In this formula, Coefficient of Discharge uses Length, Radius, Final Height of Liquid, Initial Height of Liquid, Total Time Taken & Area of Orifice. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Coefficient of Discharge = Actual Discharge/Theoretical Discharge
  • Coefficient of Discharge = (Actual Velocity*Actual Area)/(Theoretical Velocity*Theoretical Area)
  • Coefficient of Discharge = (2*Area of Tank*((sqrt(Initial Height of Liquid))-(sqrt(Final Height of Liquid))))/(Total Time Taken*Area of Orifice*sqrt(2*9.81))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!