How to Calculate Coefficient of Discharge given Discharge through Free Weir Portion?
Coefficient of Discharge given Discharge through Free Weir Portion calculator uses Coefficient of Discharge = (3*Discharge through Free Portion)/(2*Length of Weir Crest*sqrt(2*Acceleration due to Gravity)*(Head on Upstream of Weir-Head on Downstream of Weir)^(3/2)) to calculate the Coefficient of Discharge, Coefficient of discharge given discharge through free weir portion is stated as ratio between actual flow discharge and theoretical flow discharge. Coefficient of Discharge is denoted by Cd symbol.
How to calculate Coefficient of Discharge given Discharge through Free Weir Portion using this online calculator? To use this online calculator for Coefficient of Discharge given Discharge through Free Weir Portion, enter Discharge through Free Portion (Q1), Length of Weir Crest (Lw), Acceleration due to Gravity (g), Head on Upstream of Weir (HUpstream) & Head on Downstream of Weir (h2) and hit the calculate button. Here is how the Coefficient of Discharge given Discharge through Free Weir Portion calculation can be explained with given input values -> 0.506086 = (3*50.1)/(2*3*sqrt(2*9.8)*(10.1-5.1)^(3/2)).