Coefficient of Discharge given Area for Siphon Throat Solution

STEP 0: Pre-Calculation Summary
Formula Used
Discharge Coefficient = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2))
Cd' = Q/(As*(2*g*H)^(1/2))
This formula uses 5 Variables
Variables Used
Discharge Coefficient - Discharge Coefficient is the ratio of the actual discharge to the theoretical discharge.
Volume Flow Rate - (Measured in Cubic Meter per Second) - Volume Flow Rate is the volume of fluid that passes per unit of time.
Area for Siphon Throat - (Measured in Square Meter) - Area for Siphon Throat is the area of the siphon from where the discharge is released.
Acceleration Due To Gravity in Environment - (Measured in Meter per Square Second) - Acceleration Due To Gravity in Environment is the acceleration gained by an object due to gravitational force.
Head of Liquid - (Measured in Meter) - The Head of Liquid is the height of a liquid column that corresponds to a particular pressure exerted by the liquid column from the base of its container.
STEP 1: Convert Input(s) to Base Unit
Volume Flow Rate: 1.5 Cubic Meter per Second --> 1.5 Cubic Meter per Second No Conversion Required
Area for Siphon Throat: 0.12 Square Meter --> 0.12 Square Meter No Conversion Required
Acceleration Due To Gravity in Environment: 9.8 Meter per Square Second --> 9.8 Meter per Square Second No Conversion Required
Head of Liquid: 15 Meter --> 15 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cd' = Q/(As*(2*g*H)^(1/2)) --> 1.5/(0.12*(2*9.8*15)^(1/2))
Evaluating ... ...
Cd' = 0.729014804399755
STEP 3: Convert Result to Output's Unit
0.729014804399755 --> No Conversion Required
FINAL ANSWER
0.729014804399755 0.729015 <-- Discharge Coefficient
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

7 Controlling Sewer-Water Flow Calculators

Head given Area for Siphon Throat
​ Go Head of Liquid = (Volume Flow Rate/(Area for Siphon Throat*Coefficient of Discharge))^(2)*(1/(2*Acceleration Due To Gravity in Environment))
Discharge given Area for Siphon Throat
​ Go Volume Flow Rate = Area for Siphon Throat*Coefficient of Discharge*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2)
Coefficient of Discharge given Area for Siphon Throat
​ Go Discharge Coefficient = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2))
Area for Siphon Throat
​ Go Siphon Throat Area = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2))
Depth of Flow over Weir given Flow Diversion
​ Go Depth of Flow Over Weir = (Volume Flow Rate/(3.32*(Length of Weir)^0.83))^(1/1.67)
Length of Weir given Flow Diversion
​ Go Length of Weir = (Volume Flow Rate/(3.32*Depth of Flow Over Weir^1.67))^(1/0.83)
Flow Diversion for Side Weir
​ Go Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67)

Coefficient of Discharge given Area for Siphon Throat Formula

Discharge Coefficient = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2))
Cd' = Q/(As*(2*g*H)^(1/2))

What is Siphon?

A siphon is any of a wide variety of devices that involve the flow of liquids through tubes. Pipelines called inverted siphons are used to carry sewage or stormwater under streams, highway cuts, or other depressions in the ground.

How to Calculate Coefficient of Discharge given Area for Siphon Throat?

Coefficient of Discharge given Area for Siphon Throat calculator uses Discharge Coefficient = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2)) to calculate the Discharge Coefficient, The Coefficient of Discharge given Area for Siphon Throat is defined as the ratio of actual discharge to theoretical discharge. It varies from 0.6 to 0.8. Discharge Coefficient is denoted by Cd' symbol.

How to calculate Coefficient of Discharge given Area for Siphon Throat using this online calculator? To use this online calculator for Coefficient of Discharge given Area for Siphon Throat, enter Volume Flow Rate (Q), Area for Siphon Throat (As), Acceleration Due To Gravity in Environment (g) & Head of Liquid (H) and hit the calculate button. Here is how the Coefficient of Discharge given Area for Siphon Throat calculation can be explained with given input values -> 0.729015 = 1.5/(0.12*(2*9.8*15)^(1/2)).

FAQ

What is Coefficient of Discharge given Area for Siphon Throat?
The Coefficient of Discharge given Area for Siphon Throat is defined as the ratio of actual discharge to theoretical discharge. It varies from 0.6 to 0.8 and is represented as Cd' = Q/(As*(2*g*H)^(1/2)) or Discharge Coefficient = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2)). Volume Flow Rate is the volume of fluid that passes per unit of time, Area for Siphon Throat is the area of the siphon from where the discharge is released, Acceleration Due To Gravity in Environment is the acceleration gained by an object due to gravitational force & The Head of Liquid is the height of a liquid column that corresponds to a particular pressure exerted by the liquid column from the base of its container.
How to calculate Coefficient of Discharge given Area for Siphon Throat?
The Coefficient of Discharge given Area for Siphon Throat is defined as the ratio of actual discharge to theoretical discharge. It varies from 0.6 to 0.8 is calculated using Discharge Coefficient = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration Due To Gravity in Environment*Head of Liquid)^(1/2)). To calculate Coefficient of Discharge given Area for Siphon Throat, you need Volume Flow Rate (Q), Area for Siphon Throat (As), Acceleration Due To Gravity in Environment (g) & Head of Liquid (H). With our tool, you need to enter the respective value for Volume Flow Rate, Area for Siphon Throat, Acceleration Due To Gravity in Environment & Head of Liquid and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.