Chosen Air Supply given Air Supply required Solution

STEP 0: Pre-Calculation Summary
Formula Used
Chosen Air Supply = Air Supply Required*Length of Grit Chamber
A = As*L
This formula uses 3 Variables
Variables Used
Chosen Air Supply - (Measured in Square Meter per Second) - The Chosen Air Supply refers to the selected rate of airflow provided to a treatment process to ensure adequate aeration or mixing, typically measured in (m³/h) or (L/s).
Air Supply Required - (Measured in Cubic Meter per Second) - The Air Supply Required refers to the amount of air needed to maintain aerobic conditions or mixing in a treatment process, typically measured in (m³/h) or (L/s).
Length of Grit Chamber - (Measured in Meter) - The Length of Grit Chamber refers to the horizontal distance from its inlet to outlet, designed to allow grit particles to settle, typically around 10 to 20 meters.
STEP 1: Convert Input(s) to Base Unit
Air Supply Required: 0.0076 Cubic Meter per Second --> 0.0076 Cubic Meter per Second No Conversion Required
Length of Grit Chamber: 6.92 Meter --> 6.92 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
A = As*L --> 0.0076*6.92
Evaluating ... ...
A = 0.052592
STEP 3: Convert Result to Output's Unit
0.052592 Square Meter per Second --> No Conversion Required
FINAL ANSWER
0.052592 Square Meter per Second <-- Chosen Air Supply
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of an Aerated Grit Chamber Calculators

Width of Grit Chamber
​ Go Width of Grit Chamber = (Selected Width Ratio*Depth of Grit Chamber)
Volume of Each Grit Chamber
​ Go Volume of Grit Chamber = (Peak Flow Rate*Detention Time)
Peak Flow Rate given Volume of Each Grit Chamber
​ Go Peak Flow Rate = Volume of Grit Chamber/Detention Time
Detention Time given Volume of Each Grit Chamber
​ Go Detention Time = Volume of Grit Chamber/Peak Flow Rate

Chosen Air Supply given Air Supply required Formula

Chosen Air Supply = Air Supply Required*Length of Grit Chamber
A = As*L

What is Grit Chamber ?

Grit chambers are long narrow tanks that are designed to slow down the flow so that solids such as sand, coffee grounds, and eggshells will settle out of the water. Grit causes excessive wear and tear on pumps and other plant equipment.

How to Calculate Chosen Air Supply given Air Supply required?

Chosen Air Supply given Air Supply required calculator uses Chosen Air Supply = Air Supply Required*Length of Grit Chamber to calculate the Chosen Air Supply, The Chosen Air Supply given Air Supply required formula is defined as calculating the value of the selected rate of airflow provided to a treatment process to ensure adequate aeration or mixing, typically measured in (m³/h) or (L/s). Chosen Air Supply is denoted by A symbol.

How to calculate Chosen Air Supply given Air Supply required using this online calculator? To use this online calculator for Chosen Air Supply given Air Supply required, enter Air Supply Required (As) & Length of Grit Chamber (L) and hit the calculate button. Here is how the Chosen Air Supply given Air Supply required calculation can be explained with given input values -> 0.052592 = 0.0076*6.92.

FAQ

What is Chosen Air Supply given Air Supply required?
The Chosen Air Supply given Air Supply required formula is defined as calculating the value of the selected rate of airflow provided to a treatment process to ensure adequate aeration or mixing, typically measured in (m³/h) or (L/s) and is represented as A = As*L or Chosen Air Supply = Air Supply Required*Length of Grit Chamber. The Air Supply Required refers to the amount of air needed to maintain aerobic conditions or mixing in a treatment process, typically measured in (m³/h) or (L/s) & The Length of Grit Chamber refers to the horizontal distance from its inlet to outlet, designed to allow grit particles to settle, typically around 10 to 20 meters.
How to calculate Chosen Air Supply given Air Supply required?
The Chosen Air Supply given Air Supply required formula is defined as calculating the value of the selected rate of airflow provided to a treatment process to ensure adequate aeration or mixing, typically measured in (m³/h) or (L/s) is calculated using Chosen Air Supply = Air Supply Required*Length of Grit Chamber. To calculate Chosen Air Supply given Air Supply required, you need Air Supply Required (As) & Length of Grit Chamber (L). With our tool, you need to enter the respective value for Air Supply Required & Length of Grit Chamber and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.