Change in external load on bolt given external load and stiffness of boad Solution

STEP 0: Pre-Calculation Summary
Formula Used
Change in External Load = External Force on Bolt*(Stiffness of Threaded Bolt/(Stiffness of Threaded Bolt+Combined Stiffness of Gasket And Parts))
ΔPi = Pe*(kb'/(kb'+kc'))
This formula uses 4 Variables
Variables Used
Change in External Load - (Measured in Newton) - Change in External Load is the amount of variation in the externally applied force or load.
External Force on Bolt - (Measured in Newton) - The External Force on Bolt is defined as the forces caused by an external agent present outside of the system.
Stiffness of Threaded Bolt - (Measured in Newton per Meter) - Stiffness of Threaded Bolt is the extent to which the bolt resists deformation in response to an applied force.
Combined Stiffness of Gasket And Parts - (Measured in Newton per Meter) - Combined Stiffness of Gasket And Parts is the combined stiffness of two parts joined by a bolted joint and the gasket between them.
STEP 1: Convert Input(s) to Base Unit
External Force on Bolt: 6000 Newton --> 6000 Newton No Conversion Required
Stiffness of Threaded Bolt: 75000 Newton per Millimeter --> 75000000 Newton per Meter (Check conversion ​here)
Combined Stiffness of Gasket And Parts: 1200 Newton per Millimeter --> 1200000 Newton per Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ΔPi = Pe*(kb'/(kb'+kc')) --> 6000*(75000000/(75000000+1200000))
Evaluating ... ...
ΔPi = 5905.51181102362
STEP 3: Convert Result to Output's Unit
5905.51181102362 Newton --> No Conversion Required
FINAL ANSWER
5905.51181102362 5905.512 Newton <-- Change in External Load
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Vaibhav Malani
National Institute of Technology (NIT), Tiruchirapalli
Vaibhav Malani has created this Calculator and 600+ more calculators!
Verifier Image
Verified by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has verified this Calculator and 400+ more calculators!

Structural Response and Force Analysis Calculators

Tensile Stress Area of Threaded fastener
​ LaTeX ​ Go Tensile Stress Area of Threaded Fastener = pi/4*((Pitch Diameter of External Thread+Minor Diameter of External Thread)/2)^2
Tensile Stress in Core Cross-Section of Bolt given Tensile Force and Core Diameter
​ LaTeX ​ Go Tensile Stress in Bolt = Tensile Force on Bolt/(pi/4*Core Diameter of Threaded Bolt^2)
Tensile Force acting on Bolt given Tensile Stress
​ LaTeX ​ Go Tensile Force on Bolt = Tensile Stress in Bolt*pi*(Core Diameter of Threaded Bolt^2)/4
Tensile Yield Strength of Bolt
​ LaTeX ​ Go Tensile Yield Strength of Bolt = Factor of Safety For Bolt*Tensile Stress in Bolt

Change in external load on bolt given external load and stiffness of boad Formula

​LaTeX ​Go
Change in External Load = External Force on Bolt*(Stiffness of Threaded Bolt/(Stiffness of Threaded Bolt+Combined Stiffness of Gasket And Parts))
ΔPi = Pe*(kb'/(kb'+kc'))

What is a fastener?

A fastener or fastening is a hardware device that mechanically joins or affixes two or more objects together. In general, fasteners are used to create non-permanent joints; that is, joints that can be removed or dismantled without damaging the joining components.

How to Calculate Change in external load on bolt given external load and stiffness of boad?

Change in external load on bolt given external load and stiffness of boad calculator uses Change in External Load = External Force on Bolt*(Stiffness of Threaded Bolt/(Stiffness of Threaded Bolt+Combined Stiffness of Gasket And Parts)) to calculate the Change in External Load, Change in external load on bolt given external load and stiffness of boad formula is defined as the amount of change in the externally applied load onto a bolt due to the combined stiffness parameter. Change in External Load is denoted by ΔPi symbol.

How to calculate Change in external load on bolt given external load and stiffness of boad using this online calculator? To use this online calculator for Change in external load on bolt given external load and stiffness of boad, enter External Force on Bolt (Pe), Stiffness of Threaded Bolt (kb') & Combined Stiffness of Gasket And Parts (kc') and hit the calculate button. Here is how the Change in external load on bolt given external load and stiffness of boad calculation can be explained with given input values -> 5905.512 = 6000*(75000000/(75000000+1200000)).

FAQ

What is Change in external load on bolt given external load and stiffness of boad?
Change in external load on bolt given external load and stiffness of boad formula is defined as the amount of change in the externally applied load onto a bolt due to the combined stiffness parameter and is represented as ΔPi = Pe*(kb'/(kb'+kc')) or Change in External Load = External Force on Bolt*(Stiffness of Threaded Bolt/(Stiffness of Threaded Bolt+Combined Stiffness of Gasket And Parts)). The External Force on Bolt is defined as the forces caused by an external agent present outside of the system, Stiffness of Threaded Bolt is the extent to which the bolt resists deformation in response to an applied force & Combined Stiffness of Gasket And Parts is the combined stiffness of two parts joined by a bolted joint and the gasket between them.
How to calculate Change in external load on bolt given external load and stiffness of boad?
Change in external load on bolt given external load and stiffness of boad formula is defined as the amount of change in the externally applied load onto a bolt due to the combined stiffness parameter is calculated using Change in External Load = External Force on Bolt*(Stiffness of Threaded Bolt/(Stiffness of Threaded Bolt+Combined Stiffness of Gasket And Parts)). To calculate Change in external load on bolt given external load and stiffness of boad, you need External Force on Bolt (Pe), Stiffness of Threaded Bolt (kb') & Combined Stiffness of Gasket And Parts (kc'). With our tool, you need to enter the respective value for External Force on Bolt, Stiffness of Threaded Bolt & Combined Stiffness of Gasket And Parts and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Change in External Load?
In this formula, Change in External Load uses External Force on Bolt, Stiffness of Threaded Bolt & Combined Stiffness of Gasket And Parts. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Change in External Load = Resultant Load on Bolt-Initial Preload in Bolt Due to Tightening of Nut
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!