Chamber Length using Air Supply required Solution

STEP 0: Pre-Calculation Summary
Formula Used
Length of Grit Chamber = (Chosen Air Supply/Air Supply Required)
L = (A/As)
This formula uses 3 Variables
Variables Used
Length of Grit Chamber - (Measured in Meter) - The Length of Grit Chamber refers to the horizontal distance from its inlet to outlet, designed to allow grit particles to settle, typically around 10 to 20 meters.
Chosen Air Supply - (Measured in Square Meter per Second) - The Chosen Air Supply refers to the selected rate of airflow provided to a treatment process to ensure adequate aeration or mixing, typically measured in (m³/h) or (L/s).
Air Supply Required - (Measured in Cubic Meter per Second) - The Air Supply Required refers to the amount of air needed to maintain aerobic conditions or mixing in a treatment process, typically measured in (m³/h) or (L/s).
STEP 1: Convert Input(s) to Base Unit
Chosen Air Supply: 0.053 Square Meter per Second --> 0.053 Square Meter per Second No Conversion Required
Air Supply Required: 0.0076 Cubic Meter per Second --> 0.0076 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
L = (A/As) --> (0.053/0.0076)
Evaluating ... ...
L = 6.97368421052632
STEP 3: Convert Result to Output's Unit
6.97368421052632 Meter --> No Conversion Required
FINAL ANSWER
6.97368421052632 6.973684 Meter <-- Length of Grit Chamber
(Calculation completed in 00.021 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of an Aerated Grit Chamber Calculators

Width of Grit Chamber
​ LaTeX ​ Go Width of Grit Chamber = (Selected Width Ratio*Depth of Grit Chamber)
Volume of Each Grit Chamber
​ LaTeX ​ Go Volume of Grit Chamber = (Peak Flow Rate*Detention Time)
Peak Flow Rate given Volume of Each Grit Chamber
​ LaTeX ​ Go Peak Flow Rate = Volume of Grit Chamber/Detention Time
Detention Time given Volume of Each Grit Chamber
​ LaTeX ​ Go Detention Time = Volume of Grit Chamber/Peak Flow Rate

Chamber Length using Air Supply required Formula

​LaTeX ​Go
Length of Grit Chamber = (Chosen Air Supply/Air Supply Required)
L = (A/As)

What is Grit Chamber ?

Grit Chambers are long narrow tanks that are designed to slow down the flow so that solids such as sand, coffee grounds, and eggshells will settle out of the water.

How to Calculate Chamber Length using Air Supply required?

Chamber Length using Air Supply required calculator uses Length of Grit Chamber = (Chosen Air Supply/Air Supply Required) to calculate the Length of Grit Chamber, The Chamber Length using Air Supply required formula is defined as calculating the horizontal distance from its inlet to outlet, designed to allow grit particles to settle, typically around 10 to 20 meters, calculated using the value of air supply. Length of Grit Chamber is denoted by L symbol.

How to calculate Chamber Length using Air Supply required using this online calculator? To use this online calculator for Chamber Length using Air Supply required, enter Chosen Air Supply (A) & Air Supply Required (As) and hit the calculate button. Here is how the Chamber Length using Air Supply required calculation can be explained with given input values -> 1315.789 = (0.053/0.0076).

FAQ

What is Chamber Length using Air Supply required?
The Chamber Length using Air Supply required formula is defined as calculating the horizontal distance from its inlet to outlet, designed to allow grit particles to settle, typically around 10 to 20 meters, calculated using the value of air supply and is represented as L = (A/As) or Length of Grit Chamber = (Chosen Air Supply/Air Supply Required). The Chosen Air Supply refers to the selected rate of airflow provided to a treatment process to ensure adequate aeration or mixing, typically measured in (m³/h) or (L/s) & The Air Supply Required refers to the amount of air needed to maintain aerobic conditions or mixing in a treatment process, typically measured in (m³/h) or (L/s).
How to calculate Chamber Length using Air Supply required?
The Chamber Length using Air Supply required formula is defined as calculating the horizontal distance from its inlet to outlet, designed to allow grit particles to settle, typically around 10 to 20 meters, calculated using the value of air supply is calculated using Length of Grit Chamber = (Chosen Air Supply/Air Supply Required). To calculate Chamber Length using Air Supply required, you need Chosen Air Supply (A) & Air Supply Required (As). With our tool, you need to enter the respective value for Chosen Air Supply & Air Supply Required and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Length of Grit Chamber?
In this formula, Length of Grit Chamber uses Chosen Air Supply & Air Supply Required. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Length of Grit Chamber = (Volume of Grit Chamber/(Width of Grit Chamber*Depth of Grit Chamber))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!