Crushing Load given Ultimate Crushing Stress Solution

STEP 0: Pre-Calculation Summary
Formula Used
Crushing Load = Column Crushing Stress*Column Cross Sectional Area
Pc = σc*A
This formula uses 3 Variables
Variables Used
Crushing Load - (Measured in Newton) - Crushing Load is the maximum load or force that a material or structure can withstand before it undergoes failure due to crushing.
Column Crushing Stress - (Measured in Pascal) - Column Crushing Stress is a special type of localized compressive stress which occurs at the surface of contact of two members that are relatively at rest.
Column Cross Sectional Area - (Measured in Square Meter) - Column Cross Sectional Area is the area of a two-dimensional shape that is obtained when a three dimensional shape is sliced perpendicular to some specified axis at a point.
STEP 1: Convert Input(s) to Base Unit
Column Crushing Stress: 750 Megapascal --> 750000000 Pascal (Check conversion ​here)
Column Cross Sectional Area: 2000 Square Millimeter --> 0.002 Square Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pc = σc*A --> 750000000*0.002
Evaluating ... ...
Pc = 1500000
STEP 3: Convert Result to Output's Unit
1500000 Newton -->1500 Kilonewton (Check conversion ​here)
FINAL ANSWER
1500 Kilonewton <-- Crushing Load
(Calculation completed in 00.021 seconds)

Credits

Creator Image
Created by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Euler and Rankine's Theory Calculators

Crushing Load by Rankine's Formula
​ LaTeX ​ Go Crushing Load = (Rankine’s Critical Load*Euler’s Buckling Load)/(Euler’s Buckling Load-Rankine’s Critical Load)
Crippling Load by Euler's Formula given Crippling Load by Rankine's
​ LaTeX ​ Go Euler’s Buckling Load = (Crushing Load*Rankine’s Critical Load)/(Crushing Load-Rankine’s Critical Load)
Crippling Load by Rankine's
​ LaTeX ​ Go Rankine’s Critical Load = (Crushing Load*Euler’s Buckling Load)/(Crushing Load+Euler’s Buckling Load)
Crushing Load given Ultimate Crushing Stress
​ LaTeX ​ Go Crushing Load = Column Crushing Stress*Column Cross Sectional Area

Rankine's Formula Calculators

Cross-Sectional Area of Column given Crippling Load and Rankine's Constant
​ LaTeX ​ Go Column Cross Sectional Area = (Crippling Load*(1+Rankine's Constant*(Effective Column Length/Least Radius of Gyration Column)^2))/Column Crushing Stress
Crippling Load given Rankine's Constant
​ LaTeX ​ Go Crippling Load = (Column Crushing Stress*Column Cross Sectional Area)/(1+Rankine's Constant*(Effective Column Length/Least Radius of Gyration Column)^2)
Crippling Load by Rankine's
​ LaTeX ​ Go Rankine’s Critical Load = (Crushing Load*Euler’s Buckling Load)/(Crushing Load+Euler’s Buckling Load)
Cross-Sectional Area of Column given Crushing Load
​ LaTeX ​ Go Column Cross Sectional Area = Crushing Load/Column Crushing Stress

Crushing Load given Ultimate Crushing Stress Formula

​LaTeX ​Go
Crushing Load = Column Crushing Stress*Column Cross Sectional Area
Pc = σc*A

What is Ultimate Compressive Strength?

Ultimate Compressive Strength is defined as the force at which a specimen with a certain cross-section, and consisting of a particular fracturing material, fails when it is subjected to compression. The ultimate compressive strength is normally measured in N/mm2 (force per area) and is thus a stress.

How to Calculate Crushing Load given Ultimate Crushing Stress?

Crushing Load given Ultimate Crushing Stress calculator uses Crushing Load = Column Crushing Stress*Column Cross Sectional Area to calculate the Crushing Load, The Crushing Load given Ultimate Crushing Stress formula is defined as the maximum load a column can withstand before crushing, calculated based on the ultimate crushing stress and cross-sectional area of the column, providing a critical value for structural engineers to ensure the stability of columns in building design. Crushing Load is denoted by Pc symbol.

How to calculate Crushing Load given Ultimate Crushing Stress using this online calculator? To use this online calculator for Crushing Load given Ultimate Crushing Stress, enter Column Crushing Stress c) & Column Cross Sectional Area (A) and hit the calculate button. Here is how the Crushing Load given Ultimate Crushing Stress calculation can be explained with given input values -> 1.5 = 750000000*0.002.

FAQ

What is Crushing Load given Ultimate Crushing Stress?
The Crushing Load given Ultimate Crushing Stress formula is defined as the maximum load a column can withstand before crushing, calculated based on the ultimate crushing stress and cross-sectional area of the column, providing a critical value for structural engineers to ensure the stability of columns in building design and is represented as Pc = σc*A or Crushing Load = Column Crushing Stress*Column Cross Sectional Area. Column Crushing Stress is a special type of localized compressive stress which occurs at the surface of contact of two members that are relatively at rest & Column Cross Sectional Area is the area of a two-dimensional shape that is obtained when a three dimensional shape is sliced perpendicular to some specified axis at a point.
How to calculate Crushing Load given Ultimate Crushing Stress?
The Crushing Load given Ultimate Crushing Stress formula is defined as the maximum load a column can withstand before crushing, calculated based on the ultimate crushing stress and cross-sectional area of the column, providing a critical value for structural engineers to ensure the stability of columns in building design is calculated using Crushing Load = Column Crushing Stress*Column Cross Sectional Area. To calculate Crushing Load given Ultimate Crushing Stress, you need Column Crushing Stress c) & Column Cross Sectional Area (A). With our tool, you need to enter the respective value for Column Crushing Stress & Column Cross Sectional Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Crushing Load?
In this formula, Crushing Load uses Column Crushing Stress & Column Cross Sectional Area. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Crushing Load = (Rankine’s Critical Load*Euler’s Buckling Load)/(Euler’s Buckling Load-Rankine’s Critical Load)
  • Crushing Load = (Rankine’s Critical Load*Euler’s Buckling Load)/(Euler’s Buckling Load-Rankine’s Critical Load)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!