Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase Solution

STEP 0: Pre-Calculation Summary
Formula Used
Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase)
kc'1 = K*(Vs/Vmobile phase)
This formula uses 4 Variables
Variables Used
Capacity Factor given partition Coeff - The Capacity factor given partition Coeff is directly proportional to the retention factor. The longer a component is retained by the column, the greater is the capacity factor.
Partition Coefficient - The Partition Coefficient is defined as the ratio of the equilibrium concentrations of a dissolved substance in a two-phase system consisting of two largely immiscible solvents.
Volume of Stationary Phase - (Measured in Cubic Meter) - The Volume of Stationary Phase is the amount of motionless part of the chromatography column.
Volume of Mobile Phase - (Measured in Cubic Meter) - The Volume of Mobile Phase is the amount of the solvent that runs through the chromatography column.
STEP 1: Convert Input(s) to Base Unit
Partition Coefficient: 40 --> No Conversion Required
Volume of Stationary Phase: 7 Liter --> 0.007 Cubic Meter (Check conversion ​here)
Volume of Mobile Phase: 5 Liter --> 0.005 Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
kc'1 = K*(Vs/Vmobile phase) --> 40*(0.007/0.005)
Evaluating ... ...
kc'1 = 56
STEP 3: Convert Result to Output's Unit
56 --> No Conversion Required
FINAL ANSWER
56 <-- Capacity Factor given partition Coeff
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Prashant Singh
K J Somaiya College of science (K J Somaiya), Mumbai
Prashant Singh has created this Calculator and 700+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Capacity factor Calculators

Capacity Factor given Retention Volume and Unretained Volume
​ LaTeX ​ Go Capacity Factor of the Compound = (Retention Volume-Unretained Mobile Phase Volume)/Unretained Mobile Phase Volume
Capacity Factor given Retention Time and Mobile Phase Travel Time
​ LaTeX ​ Go Capacity Factor of the Compound = (Retention Time-Unretained Solute Travel Time)/Unretained Solute Travel Time
Capacity Factor of Solute 1 given Relative Retention
​ LaTeX ​ Go Capacity Factor of 1 = (Capacity Factor of Solute 2/Relative Retention)
Capacity Factor of Solute 2 given Relative Retention
​ LaTeX ​ Go Capacity Factor of 2 = (Relative Retention*Capacity Factor of Solute 1)

Number of Theoretical Plates and Capacity Factor Calculators

Number of Theoretical Plates given Length of Column and Standard Deviation
​ LaTeX ​ Go Number of Theoretical Plates given L and SD = ((Length of Column)^2)/((Standard Deviation)^2)
Number of Theoretical Plates given Length of Column and Width of Peak
​ LaTeX ​ Go Number of Theoretical Plates given L and W = (16*((Length of Column)^2))/((Width of Peak)^2)
Number of Theoretical Plates given Length and Height of Column
​ LaTeX ​ Go Number of Theoretical Plates given L and H = (Length of Column/Plate Height)
Height of Column given Number of Theoretical Plates
​ LaTeX ​ Go Plate Height given TP = (Length of Column/Number of Theoretical Plates)

Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase Formula

​LaTeX ​Go
Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase)
kc'1 = K*(Vs/Vmobile phase)

What is Chromatography?

A separation process based on the various partitioning coefficients of different solutes between the two phases.
Involving the interaction of solute(s) and two phases
Mobile phase: A gas or liquid that moves through the column.
Stationary phase: A solid or liquid that remains in place.

What are the types of Chromatography?

1) Adsorption chromatography
2) Ion-exchange chromatography
3) Partition chromatography
4) Molecular Size exclusion chromatography
5) Affinity chromatography

How to Calculate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase?

Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase calculator uses Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase) to calculate the Capacity Factor given partition Coeff, The Capacity factor given partition coefficient and volume of mobile and stationary phase formula is defined as the product of partition coefficient and ratio volume of stationary phase to the mobile phase. Capacity Factor given partition Coeff is denoted by kc'1 symbol.

How to calculate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase using this online calculator? To use this online calculator for Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase, enter Partition Coefficient (K), Volume of Stationary Phase (Vs) & Volume of Mobile Phase (Vmobile phase) and hit the calculate button. Here is how the Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase calculation can be explained with given input values -> 56 = 40*(0.007/0.005).

FAQ

What is Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase?
The Capacity factor given partition coefficient and volume of mobile and stationary phase formula is defined as the product of partition coefficient and ratio volume of stationary phase to the mobile phase and is represented as kc'1 = K*(Vs/Vmobile phase) or Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase). The Partition Coefficient is defined as the ratio of the equilibrium concentrations of a dissolved substance in a two-phase system consisting of two largely immiscible solvents, The Volume of Stationary Phase is the amount of motionless part of the chromatography column & The Volume of Mobile Phase is the amount of the solvent that runs through the chromatography column.
How to calculate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase?
The Capacity factor given partition coefficient and volume of mobile and stationary phase formula is defined as the product of partition coefficient and ratio volume of stationary phase to the mobile phase is calculated using Capacity Factor given partition Coeff = Partition Coefficient*(Volume of Stationary Phase/Volume of Mobile Phase). To calculate Capacity Factor given Partition Coefficient and Volume of Mobile and Stationary Phase, you need Partition Coefficient (K), Volume of Stationary Phase (Vs) & Volume of Mobile Phase (Vmobile phase). With our tool, you need to enter the respective value for Partition Coefficient, Volume of Stationary Phase & Volume of Mobile Phase and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!