Buttress Resistance using Head of Water Solution

STEP 0: Pre-Calculation Summary
Formula Used
Buttress Resistance in Pipe = ((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Velocity of Flowing Water^2))/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of the Liquid))*sin((Angle of Bend in Environmental Engi.)/(2)))
PBR = ((2*Acs)*(((γwater*(Vfw^2))/[g])+(γwater*H))*sin((θb)/(2)))
This formula uses 1 Constants, 1 Functions, 6 Variables
Constants Used
[g] - Gravitational acceleration on Earth Value Taken As 9.80665
Functions Used
sin - Sine is a trigonometric function that describes the ratio of the length of the opposite side of a right triangle to the length of the hypotenuse., sin(Angle)
Variables Used
Buttress Resistance in Pipe - (Measured in Newton) - Buttress Resistance in Pipe is a resistance applied in the pipe due to change in the direction of pipe.
Cross-Sectional Area - (Measured in Square Meter) - Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
Unit Weight of Water in KN per Cubic Meter - (Measured in Newton per Cubic Meter) - Unit Weight of Water in KN per Cubic Meter is the weight of water per unit volume of water.
Velocity of Flowing Water - (Measured in Meter per Second) - Velocity of Flowing Water gives the velocity of an element of fluid at a position and time.
Head of the Liquid - (Measured in Meter) - The Head of the Liquid is the height of a liquid column that corresponds to a particular pressure exerted by the liquid column from the base of its container.
Angle of Bend in Environmental Engi. - (Measured in Radian) - Angle of Bend in Environmental Engi. is defined as the angle by which pipe bends.
STEP 1: Convert Input(s) to Base Unit
Cross-Sectional Area: 13 Square Meter --> 13 Square Meter No Conversion Required
Unit Weight of Water in KN per Cubic Meter: 9.81 Kilonewton per Cubic Meter --> 9810 Newton per Cubic Meter (Check conversion ​here)
Velocity of Flowing Water: 5.67 Meter per Second --> 5.67 Meter per Second No Conversion Required
Head of the Liquid: 15 Meter --> 15 Meter No Conversion Required
Angle of Bend in Environmental Engi.: 36 Degree --> 0.62831853071784 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
PBR = ((2*Acs)*(((γwater*(Vfw^2))/[g])+(γwater*H))*sin((θb)/(2))) --> ((2*13)*(((9810*(5.67^2))/[g])+(9810*15))*sin((0.62831853071784)/(2)))
Evaluating ... ...
PBR = 1440654.82252116
STEP 3: Convert Result to Output's Unit
1440654.82252116 Newton -->1440.65482252116 Kilonewton (Check conversion ​here)
FINAL ANSWER
1440.65482252116 1440.655 Kilonewton <-- Buttress Resistance in Pipe
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Stresses at Bends Calculators

Buttress Resistance using Head of Water
​ LaTeX ​ Go Buttress Resistance in Pipe = ((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Velocity of Flowing Water^2))/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of the Liquid))*sin((Angle of Bend in Environmental Engi.)/(2)))
Angle of Bend given Head of Water and Buttress Resistance
​ LaTeX ​ Go Angle of Bend in Environmental Engi. = 2*asin(Buttress Resistance in Pipe/((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Flow Velocity of Fluid)^2)/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of Liquid in Pipe))))
Buttress Resistance using Angle of Bend
​ LaTeX ​ Go Buttress Resistance in Pipe = (2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*((Velocity of Flowing Water^2)/[g]))+Internal Water Pressure in Pipes)*sin((Angle of Bend in Environmental Engi.)/(2)))
Angle of Bend given Buttress Resistance
​ LaTeX ​ Go Angle of Bend in Environmental Engi. = 2*asin(Buttress Resistance in Pipe/((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Flow Velocity of Fluid)^2)/[g])+Water Pressure in KN per Square Meter)))

Buttress Resistance using Head of Water Formula

​LaTeX ​Go
Buttress Resistance in Pipe = ((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Velocity of Flowing Water^2))/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of the Liquid))*sin((Angle of Bend in Environmental Engi.)/(2)))
PBR = ((2*Acs)*(((γwater*(Vfw^2))/[g])+(γwater*H))*sin((θb)/(2)))

Why is Buttress Resistance necessary?

Buttress Resistance provides the external resisting force that must be exerted to overcome the outward thrust exerted on the pipe that otherwise would pull apart the pipe.

How to Calculate Buttress Resistance using Head of Water?

Buttress Resistance using Head of Water calculator uses Buttress Resistance in Pipe = ((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Velocity of Flowing Water^2))/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of the Liquid))*sin((Angle of Bend in Environmental Engi.)/(2))) to calculate the Buttress Resistance in Pipe, The Buttress Resistance using Head of Water formula is defined as the external resisting force that must be exerted to overcome the outward thrust exerted on the pipe. Buttress Resistance in Pipe is denoted by PBR symbol.

How to calculate Buttress Resistance using Head of Water using this online calculator? To use this online calculator for Buttress Resistance using Head of Water, enter Cross-Sectional Area (Acs), Unit Weight of Water in KN per Cubic Meter water), Velocity of Flowing Water (Vfw), Head of the Liquid (H) & Angle of Bend in Environmental Engi. b) and hit the calculate button. Here is how the Buttress Resistance using Head of Water calculation can be explained with given input values -> 1.440655 = ((2*13)*(((9810*(5.67^2))/[g])+(9810*15))*sin((0.62831853071784)/(2))).

FAQ

What is Buttress Resistance using Head of Water?
The Buttress Resistance using Head of Water formula is defined as the external resisting force that must be exerted to overcome the outward thrust exerted on the pipe and is represented as PBR = ((2*Acs)*(((γwater*(Vfw^2))/[g])+(γwater*H))*sin((θb)/(2))) or Buttress Resistance in Pipe = ((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Velocity of Flowing Water^2))/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of the Liquid))*sin((Angle of Bend in Environmental Engi.)/(2))). Cross-Sectional Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point, Unit Weight of Water in KN per Cubic Meter is the weight of water per unit volume of water, Velocity of Flowing Water gives the velocity of an element of fluid at a position and time, The Head of the Liquid is the height of a liquid column that corresponds to a particular pressure exerted by the liquid column from the base of its container & Angle of Bend in Environmental Engi. is defined as the angle by which pipe bends.
How to calculate Buttress Resistance using Head of Water?
The Buttress Resistance using Head of Water formula is defined as the external resisting force that must be exerted to overcome the outward thrust exerted on the pipe is calculated using Buttress Resistance in Pipe = ((2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*(Velocity of Flowing Water^2))/[g])+(Unit Weight of Water in KN per Cubic Meter*Head of the Liquid))*sin((Angle of Bend in Environmental Engi.)/(2))). To calculate Buttress Resistance using Head of Water, you need Cross-Sectional Area (Acs), Unit Weight of Water in KN per Cubic Meter water), Velocity of Flowing Water (Vfw), Head of the Liquid (H) & Angle of Bend in Environmental Engi. b). With our tool, you need to enter the respective value for Cross-Sectional Area, Unit Weight of Water in KN per Cubic Meter, Velocity of Flowing Water, Head of the Liquid & Angle of Bend in Environmental Engi and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Buttress Resistance in Pipe?
In this formula, Buttress Resistance in Pipe uses Cross-Sectional Area, Unit Weight of Water in KN per Cubic Meter, Velocity of Flowing Water, Head of the Liquid & Angle of Bend in Environmental Engi. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Buttress Resistance in Pipe = (2*Cross-Sectional Area)*(((Unit Weight of Water in KN per Cubic Meter*((Velocity of Flowing Water^2)/[g]))+Internal Water Pressure in Pipes)*sin((Angle of Bend in Environmental Engi.)/(2)))