BOD of Influent Sewage given BOD Load Applied Solution

STEP 0: Pre-Calculation Summary
Formula Used
Influent BOD = Daily BOD/Sewage Flow
Qi = BOD/Q
This formula uses 3 Variables
Variables Used
Influent BOD - (Measured in Kilogram per Cubic Meter) - Influent BOD is the total amount of BOD which is present in the incoming sewage.
Daily BOD - (Measured in Kilogram) - Daily BOD load measures the amount of oxygen that microorganisms will consume while decomposing organic matter in a water sample over a 24-hour period.
Sewage Flow - (Measured in Cubic Meter) - Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
STEP 1: Convert Input(s) to Base Unit
Daily BOD: 3 Milligram --> 3E-06 Kilogram (Check conversion ​here)
Sewage Flow: 3.33 Cubic Meter --> 3.33 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qi = BOD/Q --> 3E-06/3.33
Evaluating ... ...
Qi = 9.00900900900901E-07
STEP 3: Convert Result to Output's Unit
9.00900900900901E-07 Kilogram per Cubic Meter -->0.000900900900900901 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
0.000900900900900901 0.000901 Milligram per Liter <-- Influent BOD
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Food is to Microorganism Ratio or F is to M Ratio Calculators

BOD Load applied to Aeration System
​ LaTeX ​ Go BOD Load applied to Aeration System = Sewage Flow*Influent BOD
Total Microbial Mass given Food to Microorganism Ratio
​ LaTeX ​ Go Total Microbial Mass = Daily BOD/Food to Microorganism Ratio
Daily BOD Load given Food to Microorganism Ratio
​ LaTeX ​ Go Daily BOD = Food to Microorganism Ratio*Total Microbial Mass
Food to Microorganism Ratio
​ LaTeX ​ Go Food to Microorganism Ratio = Daily BOD/Total Microbial Mass

BOD of Influent Sewage given BOD Load Applied Formula

​LaTeX ​Go
Influent BOD = Daily BOD/Sewage Flow
Qi = BOD/Q

What is BOD?

Biochemical oxygen demand is the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material present in a given water sample at certain temperature over a specific time period.

How to Calculate BOD of Influent Sewage given BOD Load Applied?

BOD of Influent Sewage given BOD Load Applied calculator uses Influent BOD = Daily BOD/Sewage Flow to calculate the Influent BOD, The BOD of Influent Sewage given BOD Load Applied formula is defined as the calculation of BOD of influent sewage when we have prior information of applied BOD load. Influent BOD is denoted by Qi symbol.

How to calculate BOD of Influent Sewage given BOD Load Applied using this online calculator? To use this online calculator for BOD of Influent Sewage given BOD Load Applied, enter Daily BOD (BOD) & Sewage Flow (Q) and hit the calculate button. Here is how the BOD of Influent Sewage given BOD Load Applied calculation can be explained with given input values -> 0.15 = 3E-06/3.33.

FAQ

What is BOD of Influent Sewage given BOD Load Applied?
The BOD of Influent Sewage given BOD Load Applied formula is defined as the calculation of BOD of influent sewage when we have prior information of applied BOD load and is represented as Qi = BOD/Q or Influent BOD = Daily BOD/Sewage Flow. Daily BOD load measures the amount of oxygen that microorganisms will consume while decomposing organic matter in a water sample over a 24-hour period & Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
How to calculate BOD of Influent Sewage given BOD Load Applied?
The BOD of Influent Sewage given BOD Load Applied formula is defined as the calculation of BOD of influent sewage when we have prior information of applied BOD load is calculated using Influent BOD = Daily BOD/Sewage Flow. To calculate BOD of Influent Sewage given BOD Load Applied, you need Daily BOD (BOD) & Sewage Flow (Q). With our tool, you need to enter the respective value for Daily BOD & Sewage Flow and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Influent BOD?
In this formula, Influent BOD uses Daily BOD & Sewage Flow. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Influent BOD = (Daily BOD*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow)