BOD in given Quantity of Volatile Solids Solution

STEP 0: Pre-Calculation Summary
Formula Used
BOD In = (Volatile Solids Produced/Yield Coefficient)*(1-Endogenous Coefficient*Mean Cell Residence Time)+BOD Out
BODin = (Px/Y)*(1-kd*θc)+BODout
This formula uses 6 Variables
Variables Used
BOD In - (Measured in Kilogram per Second) - BOD In in anaerobic digester design lies in its role as an indicator of the organic load present in the feedstock. High BOD levels suggest a greater concentration of organic matter.
Volatile Solids Produced - (Measured in Kilogram per Second) - Volatile Solids Produced refers to the organic fraction of the total solids present in the sludge.
Yield Coefficient - Yield Coefficient is referred as the ratio of biomass (microbial cells) produced to the amount of substrate (organic material) consumed during the digestion process.
Endogenous Coefficient - (Measured in 1 Per Second) - Endogenous Coefficient is referred as modeling the behavior of microorganisms, particularly in wastewater treatment processes.
Mean Cell Residence Time - (Measured in Second) - Mean Cell Residence Time refers to a measure of the extent to which organic matter in sludge has been decomposed or stabilized through treatment processes.
BOD Out - (Measured in Kilogram per Second) - BOD Out referred as the amount of dissolved oxygen exits anaerobic digester.
STEP 1: Convert Input(s) to Base Unit
Volatile Solids Produced: 100 Kilogram per Day --> 0.00115740740740741 Kilogram per Second (Check conversion ​here)
Yield Coefficient: 0.41 --> No Conversion Required
Endogenous Coefficient: 0.05 1 Per Day --> 5.78703703703704E-07 1 Per Second (Check conversion ​here)
Mean Cell Residence Time: 6.96 Day --> 601344 Second (Check conversion ​here)
BOD Out: 4.9 Kilogram per Day --> 5.6712962962963E-05 Kilogram per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
BODin = (Px/Y)*(1-kdc)+BODout --> (0.00115740740740741/0.41)*(1-5.78703703703704E-07*601344)+5.6712962962963E-05
Evaluating ... ...
BODin = 0.00189727303523036
STEP 3: Convert Result to Output's Unit
0.00189727303523036 Kilogram per Second -->163.924390243903 Kilogram per Day (Check conversion ​here)
FINAL ANSWER
163.924390243903 163.9244 Kilogram per Day <-- BOD In
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of an Anaerobic Digester Calculators

Influent Sludge Flow Rate given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Influent Sludge Flow Rate = (Volume/Hydraulic Retention Time)
Volume Required for Anaerobic Digester
​ LaTeX ​ Go Volume = (Hydraulic Retention Time*Influent Sludge Flow Rate)
Hydraulic Retention Time given Volume Required for Anaerobic Digester
​ LaTeX ​ Go Hydraulic Retention = (Volume/Influent Sludge Flow Rate)
Volumetric Loading in Anaerobic Digester
​ LaTeX ​ Go Volumetric Loading = (BOD per Day/Volumetric Flow Rate)

BOD in given Quantity of Volatile Solids Formula

​LaTeX ​Go
BOD In = (Volatile Solids Produced/Yield Coefficient)*(1-Endogenous Coefficient*Mean Cell Residence Time)+BOD Out
BODin = (Px/Y)*(1-kd*θc)+BODout

What is Biologic Oxygen Demand?

Biological oxygen demand (BOD) (also called biochemical oxygen demand) refers to the amount of oxygen that would be consumed if all the organic materials in a one liter water sample were oxidised by bacteria and protozoa.

How to Calculate BOD in given Quantity of Volatile Solids?

BOD in given Quantity of Volatile Solids calculator uses BOD In = (Volatile Solids Produced/Yield Coefficient)*(1-Endogenous Coefficient*Mean Cell Residence Time)+BOD Out to calculate the BOD In, The BOD in given Quantity of Volatile Solids formula is defined as the critical parameter used to gauge the amount of organic matter in water, which indicates the level of pollution. It measures the amount of dissolved oxygen required by aerobic microorganisms to decompose the organic material present in a water sample over a specified period, typically five days at 20°C. BOD In is denoted by BODin symbol.

How to calculate BOD in given Quantity of Volatile Solids using this online calculator? To use this online calculator for BOD in given Quantity of Volatile Solids, enter Volatile Solids Produced (Px), Yield Coefficient (Y), Endogenous Coefficient (kd), Mean Cell Residence Time c) & BOD Out (BODout) and hit the calculate button. Here is how the BOD in given Quantity of Volatile Solids calculation can be explained with given input values -> 1.4E+7 = (0.00115740740740741/0.41)*(1-5.78703703703704E-07*601344)+5.6712962962963E-05.

FAQ

What is BOD in given Quantity of Volatile Solids?
The BOD in given Quantity of Volatile Solids formula is defined as the critical parameter used to gauge the amount of organic matter in water, which indicates the level of pollution. It measures the amount of dissolved oxygen required by aerobic microorganisms to decompose the organic material present in a water sample over a specified period, typically five days at 20°C and is represented as BODin = (Px/Y)*(1-kdc)+BODout or BOD In = (Volatile Solids Produced/Yield Coefficient)*(1-Endogenous Coefficient*Mean Cell Residence Time)+BOD Out. Volatile Solids Produced refers to the organic fraction of the total solids present in the sludge, Yield Coefficient is referred as the ratio of biomass (microbial cells) produced to the amount of substrate (organic material) consumed during the digestion process, Endogenous Coefficient is referred as modeling the behavior of microorganisms, particularly in wastewater treatment processes, Mean Cell Residence Time refers to a measure of the extent to which organic matter in sludge has been decomposed or stabilized through treatment processes & BOD Out referred as the amount of dissolved oxygen exits anaerobic digester.
How to calculate BOD in given Quantity of Volatile Solids?
The BOD in given Quantity of Volatile Solids formula is defined as the critical parameter used to gauge the amount of organic matter in water, which indicates the level of pollution. It measures the amount of dissolved oxygen required by aerobic microorganisms to decompose the organic material present in a water sample over a specified period, typically five days at 20°C is calculated using BOD In = (Volatile Solids Produced/Yield Coefficient)*(1-Endogenous Coefficient*Mean Cell Residence Time)+BOD Out. To calculate BOD in given Quantity of Volatile Solids, you need Volatile Solids Produced (Px), Yield Coefficient (Y), Endogenous Coefficient (kd), Mean Cell Residence Time c) & BOD Out (BODout). With our tool, you need to enter the respective value for Volatile Solids Produced, Yield Coefficient, Endogenous Coefficient, Mean Cell Residence Time & BOD Out and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate BOD In?
In this formula, BOD In uses Volatile Solids Produced, Yield Coefficient, Endogenous Coefficient, Mean Cell Residence Time & BOD Out. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • BOD In = (Volume of Methane/5.62)+BOD Out+(1.42*Volatile Solids Produced)
  • BOD In = (BOD Out*100+142*Volatile Solids Produced)/(100-Percent Stabilization)