Biot Number given Heat Transfer Coefficient and Time Constant Solution

STEP 0: Pre-Calculation Summary
Formula Used
Biot Number = (Heat Transfer Coefficient*Surface Area for Convection*Time Constant)/(Density of Body*Specific Heat Capacity*Volume of Object*Fourier Number)
Bi = (h*Ac*𝜏)/(ρB*c*V*Fo)
This formula uses 8 Variables
Variables Used
Biot Number - Biot Number is a dimensionless quantity having the ratio of internal conduction resistance to the surface convection resistance.
Heat Transfer Coefficient - (Measured in Watt per Square Meter per Kelvin) - The Heat Transfer Coefficient is the heat transferred per unit area per kelvin. Thus area is included in the equation as it represents the area over which the transfer of heat takes place.
Surface Area for Convection - (Measured in Square Meter) - Surface Area for Convection is defined as the surface area of object which is in the process of heat transfer.
Time Constant - (Measured in Second) - Time Constant is defined as the total time taken for a body to attain final temperature from initial temperature.
Density of Body - (Measured in Kilogram per Cubic Meter) - Density of Body is the physical quantity that expresses the relationship between its mass and its volume.
Specific Heat Capacity - (Measured in Joule per Kilogram per K) - Specific Heat Capacity is the heat required to raise the temperature of the unit mass of a given substance by a given amount.
Volume of Object - (Measured in Cubic Meter) - Volume of Object is the amount of space that a substance or object occupies or that is enclosed within a container.
Fourier Number - Fourier Number is the ratio of diffusive or conductive transport rate to the quantity storage rate, where the quantity may be either heat or matter.
STEP 1: Convert Input(s) to Base Unit
Heat Transfer Coefficient: 10 Watt per Square Meter per Kelvin --> 10 Watt per Square Meter per Kelvin No Conversion Required
Surface Area for Convection: 0.00785 Square Meter --> 0.00785 Square Meter No Conversion Required
Time Constant: 1937 Second --> 1937 Second No Conversion Required
Density of Body: 15 Kilogram per Cubic Meter --> 15 Kilogram per Cubic Meter No Conversion Required
Specific Heat Capacity: 1.5 Joule per Kilogram per K --> 1.5 Joule per Kilogram per K No Conversion Required
Volume of Object: 6.541 Cubic Meter --> 6.541 Cubic Meter No Conversion Required
Fourier Number: 1.134 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Bi = (h*Ac*𝜏)/(ρB*c*V*Fo) --> (10*0.00785*1937)/(15*1.5*6.541*1.134)
Evaluating ... ...
Bi = 0.911086382783427
STEP 3: Convert Result to Output's Unit
0.911086382783427 --> No Conversion Required
FINAL ANSWER
0.911086382783427 0.911086 <-- Biot Number
(Calculation completed in 00.005 seconds)

Credits

Creator Image
Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Unsteady State Heat Conduction Calculators

Fourier Number using Biot Number
​ LaTeX ​ Go Fourier Number = (-1/(Biot Number))*ln((Temperature at Any Time T-Temperature of Bulk Fluid)/(Initial Temperature of Object-Temperature of Bulk Fluid))
Biot Number using Fourier Number
​ LaTeX ​ Go Biot Number = (-1/Fourier Number)*ln((Temperature at Any Time T-Temperature of Bulk Fluid)/(Initial Temperature of Object-Temperature of Bulk Fluid))
Initial Internal Energy Content of Body in Reference to Environment Temperature
​ LaTeX ​ Go Initial Energy Content = Density of Body*Specific Heat Capacity*Volume of Object*(Initial Temperature of Solid-Ambient Temperature)
Biot Number using Heat Transfer Coefficient
​ LaTeX ​ Go Biot Number = (Heat Transfer Coefficient*Thickness of Wall)/Thermal Conductivity

Biot Number given Heat Transfer Coefficient and Time Constant Formula

​LaTeX ​Go
Biot Number = (Heat Transfer Coefficient*Surface Area for Convection*Time Constant)/(Density of Body*Specific Heat Capacity*Volume of Object*Fourier Number)
Bi = (h*Ac*𝜏)/(ρB*c*V*Fo)

What is Unsteady State Heat Transfer?

Unsteady State Heat Transfer refers to the heat transfer process in which a system's temperature changes with time. This type of heat transfer can happen in different forms, such as conduction, convection, and radiation. It occurs in various systems, including solid materials, fluids, and gases. The heat transfer rate in an unsteady state is directly proportional to the rate of temperature change. This means that the heat transfer rate is not constant and can vary over time. It's an important aspect in the design and optimization of thermal systems, and understanding this process is crucial in many research areas, such as combustion, electronics, and aerospace.

What are Dimensionless Number?

Dimensionless numbers or non-dimensional numbers are those which are useful to determine the flow characteristics of a fluid. Inertia force always exists if there is any mass in motion. Dividing this inertia force with other forces like viscous force, gravity force, surface tension, elastic force, or pressure force, gives us the dimensionless numbers.

How to Calculate Biot Number given Heat Transfer Coefficient and Time Constant?

Biot Number given Heat Transfer Coefficient and Time Constant calculator uses Biot Number = (Heat Transfer Coefficient*Surface Area for Convection*Time Constant)/(Density of Body*Specific Heat Capacity*Volume of Object*Fourier Number) to calculate the Biot Number, The Biot Number given Heat Transfer Coefficient and Time Constant formula is defined as the function of heat transfer coefficient, surface area for convection, time constant, density of body, specific heat capacity, volume of object and fourier number. The exponential part of Lumped Heat capacity equation can also be expressed as the the product of Biot number and fourier number. Biot Number is denoted by Bi symbol.

How to calculate Biot Number given Heat Transfer Coefficient and Time Constant using this online calculator? To use this online calculator for Biot Number given Heat Transfer Coefficient and Time Constant, enter Heat Transfer Coefficient (h), Surface Area for Convection (Ac), Time Constant (𝜏), Density of Body B), Specific Heat Capacity (c), Volume of Object (V) & Fourier Number (Fo) and hit the calculate button. Here is how the Biot Number given Heat Transfer Coefficient and Time Constant calculation can be explained with given input values -> 0.911086 = (10*0.00785*1937)/(15*1.5*6.541*1.134).

FAQ

What is Biot Number given Heat Transfer Coefficient and Time Constant?
The Biot Number given Heat Transfer Coefficient and Time Constant formula is defined as the function of heat transfer coefficient, surface area for convection, time constant, density of body, specific heat capacity, volume of object and fourier number. The exponential part of Lumped Heat capacity equation can also be expressed as the the product of Biot number and fourier number and is represented as Bi = (h*Ac*𝜏)/(ρB*c*V*Fo) or Biot Number = (Heat Transfer Coefficient*Surface Area for Convection*Time Constant)/(Density of Body*Specific Heat Capacity*Volume of Object*Fourier Number). The Heat Transfer Coefficient is the heat transferred per unit area per kelvin. Thus area is included in the equation as it represents the area over which the transfer of heat takes place, Surface Area for Convection is defined as the surface area of object which is in the process of heat transfer, Time Constant is defined as the total time taken for a body to attain final temperature from initial temperature, Density of Body is the physical quantity that expresses the relationship between its mass and its volume, Specific Heat Capacity is the heat required to raise the temperature of the unit mass of a given substance by a given amount, Volume of Object is the amount of space that a substance or object occupies or that is enclosed within a container & Fourier Number is the ratio of diffusive or conductive transport rate to the quantity storage rate, where the quantity may be either heat or matter.
How to calculate Biot Number given Heat Transfer Coefficient and Time Constant?
The Biot Number given Heat Transfer Coefficient and Time Constant formula is defined as the function of heat transfer coefficient, surface area for convection, time constant, density of body, specific heat capacity, volume of object and fourier number. The exponential part of Lumped Heat capacity equation can also be expressed as the the product of Biot number and fourier number is calculated using Biot Number = (Heat Transfer Coefficient*Surface Area for Convection*Time Constant)/(Density of Body*Specific Heat Capacity*Volume of Object*Fourier Number). To calculate Biot Number given Heat Transfer Coefficient and Time Constant, you need Heat Transfer Coefficient (h), Surface Area for Convection (Ac), Time Constant (𝜏), Density of Body B), Specific Heat Capacity (c), Volume of Object (V) & Fourier Number (Fo). With our tool, you need to enter the respective value for Heat Transfer Coefficient, Surface Area for Convection, Time Constant, Density of Body, Specific Heat Capacity, Volume of Object & Fourier Number and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Biot Number?
In this formula, Biot Number uses Heat Transfer Coefficient, Surface Area for Convection, Time Constant, Density of Body, Specific Heat Capacity, Volume of Object & Fourier Number. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Biot Number = (Heat Transfer Coefficient*Thickness of Wall)/Thermal Conductivity
  • Biot Number = (-1/Fourier Number)*ln((Temperature at Any Time T-Temperature of Bulk Fluid)/(Initial Temperature of Object-Temperature of Bulk Fluid))
  • Biot Number = (Heat Transfer Coefficient*Time Constant)/(Density of Body*Specific Heat Capacity*Characteristic Dimension*Fourier Number)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!