Bearing Stress in Local Zone Solution

STEP 0: Pre-Calculation Summary
Formula Used
Bearing Stress = Prestressing Force/Punching Area
fbr = F/Apun
This formula uses 3 Variables
Variables Used
Bearing Stress - (Measured in Pascal) - Bearing Stress is described as the contact pressure between the separate bodies.
Prestressing Force - (Measured in Newton) - Prestressing Force is the force internally applied to the prestressed concrete section.
Punching Area - (Measured in Square Meter) - Punching area can be described as the defined as the space occupied by a flat shape or the surface of an object.
STEP 1: Convert Input(s) to Base Unit
Prestressing Force: 400 Kilonewton --> 400000 Newton (Check conversion ​here)
Punching Area: 0.008 Square Meter --> 0.008 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
fbr = F/Apun --> 400000/0.008
Evaluating ... ...
fbr = 50000000
STEP 3: Convert Result to Output's Unit
50000000 Pascal -->50 Newton per Square Millimeter (Check conversion ​here)
FINAL ANSWER
50 Newton per Square Millimeter <-- Bearing Stress
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Post Tensioned Members Calculators

Prestress in Tendon given Bursting Force for Square End Zone
​ LaTeX ​ Go Prestressing Force = Prestress Bursting force/(0.32-0.3*(Side Length of Bearing Plate/Traverse Dimension of End Zone))
Bursting Force for Square End Zone
​ LaTeX ​ Go Prestress Bursting force = Prestressing Force*(0.32-0.3*(Side Length of Bearing Plate/Traverse Dimension of End Zone))
End Zone Reinforcement along Transmission Length
​ LaTeX ​ Go End Zone Reinforcement = (2.5*Moment in Structures)/(Allowable Stress*Total Depth)
Allowable Stress given End Zone Reinforcement
​ LaTeX ​ Go Allowable Stress = (2.5*Moment in Structures)/(End Zone Reinforcement*Total Depth)

Bearing Stress in Local Zone Formula

​LaTeX ​Go
Bearing Stress = Prestressing Force/Punching Area
fbr = F/Apun

What is meant by Prestress in Tendon?

Prestress in Tendon is defined to introduce internal stresses into (something, such as a structural beam) to counteract the stresses that will result from applied load. A tendon for prestressed concrete structure comprises a core member such as a steel wire for prestressed concrete structures, a steel strand for prestressed concrete structures or a steel bar for prestressed concrete structures, and an unset bonding material coating the core structure in a predetermined thickness, having a specific setting time determined by selectively determining the respective contents of the ingredient of the bonding material and capable of setting at an ordinary temperature.

What is the difference between Normal Stress and Bearing Stress?

Normal Stress -
A normal stress is a stress that occurs when a member is loaded by an axial force. The value of the normal force for any prismatic section is simply the force divided by the cross sectional area.
A normal stress will occur when a member is placed in tension or compression. Examples of members experiencing pure normal forces would include columns, collar ties, etc.

Bearing Stress -
Bearing stress is the contact pressure between the separate bodies. It differs from compressive stress, as it is an internal stress caused by compressive forces.

How to Calculate Bearing Stress in Local Zone?

Bearing Stress in Local Zone calculator uses Bearing Stress = Prestressing Force/Punching Area to calculate the Bearing Stress, The Bearing Stress in Local Zone formula is defined as the contact pressure between the separate bodies it differs from compressive stress as it is an internal stress caused by a load. Bearing Stress is denoted by fbr symbol.

How to calculate Bearing Stress in Local Zone using this online calculator? To use this online calculator for Bearing Stress in Local Zone, enter Prestressing Force (F) & Punching Area (Apun) and hit the calculate button. Here is how the Bearing Stress in Local Zone calculation can be explained with given input values -> 8E-9 = 400000/0.008.

FAQ

What is Bearing Stress in Local Zone?
The Bearing Stress in Local Zone formula is defined as the contact pressure between the separate bodies it differs from compressive stress as it is an internal stress caused by a load and is represented as fbr = F/Apun or Bearing Stress = Prestressing Force/Punching Area. Prestressing Force is the force internally applied to the prestressed concrete section & Punching area can be described as the defined as the space occupied by a flat shape or the surface of an object.
How to calculate Bearing Stress in Local Zone?
The Bearing Stress in Local Zone formula is defined as the contact pressure between the separate bodies it differs from compressive stress as it is an internal stress caused by a load is calculated using Bearing Stress = Prestressing Force/Punching Area. To calculate Bearing Stress in Local Zone, you need Prestressing Force (F) & Punching Area (Apun). With our tool, you need to enter the respective value for Prestressing Force & Punching Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!