Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web Solution

STEP 0: Pre-Calculation Summary
Formula Used
Thickness = Projection of Base Plate Beyond Flange*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length))
t = m*sqrt(2*Pu/(0.9*Fy*B*N))
This formula uses 1 Functions, 6 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Thickness - (Measured in Millimeter) - The thickness of the base plate.
Projection of Base Plate Beyond Flange - (Measured in Millimeter) - Projection of base plate beyond flange is distance between base plate beyond the flange and parallel to the web.
Factored Load - (Measured in Kilonewton) - Factored Load is a load multiplied by a certain factor designated by codes of practice to determine the strength of a structural members.
Yield Load - (Measured in Kilonewton) - Yield load is the load value at the point of yield; that is, where plastic deformation begins in stress strain curve.
Width - (Measured in Millimeter) - The width is parallel to the flanges.
Length - (Measured in Millimeter) - The length of a rectangular base plate for a wide-flange column.
STEP 1: Convert Input(s) to Base Unit
Projection of Base Plate Beyond Flange: 75 Millimeter --> 75 Millimeter No Conversion Required
Factored Load: 39381 Kilonewton --> 39381 Kilonewton No Conversion Required
Yield Load: 350 Kilonewton --> 350 Kilonewton No Conversion Required
Width: 40 Millimeter --> 40 Millimeter No Conversion Required
Length: 30 Millimeter --> 30 Millimeter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
t = m*sqrt(2*Pu/(0.9*Fy*B*N)) --> 75*sqrt(2*39381/(0.9*350*40*30))
Evaluating ... ...
t = 34.2352679473751
STEP 3: Convert Result to Output's Unit
0.0342352679473751 Meter -->34.2352679473751 Millimeter (Check conversion ​here)
FINAL ANSWER
34.2352679473751 34.23527 Millimeter <-- Thickness
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Alithea Fernandes
Don Bosco College of Engineering (DBCE), Goa
Alithea Fernandes has verified this Calculator and 100+ more calculators!

Column Base Plate Design Calculators

Specified Compressive Strength of Concrete using Nominal Bearing Strength
​ LaTeX ​ Go Specified Compressive Strength of Concrete = (Nominal Bearing Strength/0.85)*sqrt(Area of Base Plate/Area of supporting Concrete)
Nominal Bearing Strength of Concrete
​ LaTeX ​ Go Nominal Bearing Strength = Specified Compressive Strength of Concrete*0.85*sqrt(Area of supporting Concrete/Area of Base Plate)
Area of Supporting Concrete given Nominal Bearing Strength
​ LaTeX ​ Go Area of supporting Concrete = Area of Base Plate*((Nominal Bearing Strength/(Specified Compressive Strength of Concrete*0.85))^2)
Area of Base Plate given Nominal Bearing Strength
​ LaTeX ​ Go Area of Base Plate = Area of supporting Concrete/((Nominal Bearing Strength/(Specified Compressive Strength of Concrete*0.85))^2)

Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web Formula

​LaTeX ​Go
Thickness = Projection of Base Plate Beyond Flange*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length))
t = m*sqrt(2*Pu/(0.9*Fy*B*N))

How do you make a Base Plate?

The base plate should be of sufficient size, stiffness and strength to transmit the axial compressive force from the column to the foundation through the bedding material, without exceeding the local bearing resistance of the foundation.

What is Base Plate and its use?

Base plate is a plate that serves as a base or support. Column bases are used as a steel-concrete interface between steel columns and their foundations. Their main function is to transmit the structural stresses to the concrete footing surface and to link the column bottom end to the footing.

How to Calculate Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web?

Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web calculator uses Thickness = Projection of Base Plate Beyond Flange*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length)) to calculate the Thickness, The Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web formula is defined as thickness of a rectangular base plate for a wide-flange column. Thickness is denoted by t symbol.

How to calculate Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web using this online calculator? To use this online calculator for Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web, enter Projection of Base Plate Beyond Flange (m), Factored Load (Pu), Yield Load (Fy), Width (B) & Length (N) and hit the calculate button. Here is how the Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web calculation can be explained with given input values -> 34235.27 = 0.075*sqrt(2*39381000/(0.9*350000*0.04*0.03)).

FAQ

What is Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web?
The Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web formula is defined as thickness of a rectangular base plate for a wide-flange column and is represented as t = m*sqrt(2*Pu/(0.9*Fy*B*N)) or Thickness = Projection of Base Plate Beyond Flange*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length)). Projection of base plate beyond flange is distance between base plate beyond the flange and parallel to the web, Factored Load is a load multiplied by a certain factor designated by codes of practice to determine the strength of a structural members, Yield load is the load value at the point of yield; that is, where plastic deformation begins in stress strain curve, The width is parallel to the flanges & The length of a rectangular base plate for a wide-flange column.
How to calculate Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web?
The Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web formula is defined as thickness of a rectangular base plate for a wide-flange column is calculated using Thickness = Projection of Base Plate Beyond Flange*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length)). To calculate Base Plate Thickness given Projection of Base Plate beyond Flange and Parallel to Web, you need Projection of Base Plate Beyond Flange (m), Factored Load (Pu), Yield Load (Fy), Width (B) & Length (N). With our tool, you need to enter the respective value for Projection of Base Plate Beyond Flange, Factored Load, Yield Load, Width & Length and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Thickness?
In this formula, Thickness uses Projection of Base Plate Beyond Flange, Factored Load, Yield Load, Width & Length. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Thickness = Projection of Base Plate Beyond Edge*sqrt(2*Factored Load/(0.9*Yield Load*Width*Length))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!