Back EMF of Synchronous Motor given Armature Winding Constant Solution

STEP 0: Pre-Calculation Summary
Formula Used
Back EMF = Armature Winding Constant*Magnetic Flux*Synchronous Speed
Eb = Ka*Φ*Ns
This formula uses 4 Variables
Variables Used
Back EMF - (Measured in Volt) - Back EMF is a voltage that is generated in a motor or generator due to the motion of the armature or rotor. It is called "back" EMF as its polarity opposes the voltage applied.
Armature Winding Constant - Armature Winding Constant is defined as the ratio of the voltage applied to the motor terminals to the speed of the motor under no-load conditions.
Magnetic Flux - (Measured in Weber) - Magnetic flux (Φ) is the number of magnetic field lines passing through the magnetic core of an electrical dc motor.
Synchronous Speed - (Measured in Radian per Second) - Synchronous speed is a definite speed for an alternating-current machine that is dependent on the frequency of the supply circuit.
STEP 1: Convert Input(s) to Base Unit
Armature Winding Constant: 0.61 --> No Conversion Required
Magnetic Flux: 0.12 Weber --> 0.12 Weber No Conversion Required
Synchronous Speed: 23300 Revolution per Minute --> 2439.97029416382 Radian per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Eb = Ka*Φ*Ns --> 0.61*0.12*2439.97029416382
Evaluating ... ...
Eb = 178.605825532792
STEP 3: Convert Result to Output's Unit
178.605825532792 Volt --> No Conversion Required
FINAL ANSWER
178.605825532792 178.6058 Volt <-- Back EMF
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Voltage and EMF Calculators

Load Voltage of Synchronous Motor given 3 Phase Mechanical Power
​ LaTeX ​ Go Load Voltage = (Three Phase Mechanical Power+3*Armature Current^2*Armature Resistance)/(sqrt(3)*Load Current*cos(Phase Difference))
Load Voltage of Synchronous Motor using 3 Phase Input Power
​ LaTeX ​ Go Load Voltage = Three Phase Input Power/(sqrt(3)*Load Current*cos(Phase Difference))
Back EMF of Synchronous Motor using Mechanical Power
​ LaTeX ​ Go Back EMF = Mechanical Power/(Armature Current*cos(Load Angle-Phase Difference))
Voltage of Synchronous Motor given Input Power
​ LaTeX ​ Go Voltage = Input Power/(Armature Current*cos(Phase Difference))

Back EMF of Synchronous Motor given Armature Winding Constant Formula

​LaTeX ​Go
Back EMF = Armature Winding Constant*Magnetic Flux*Synchronous Speed
Eb = Ka*Φ*Ns

How does back EMF affects synchronous motor?

Back EMF (Electromotive Force) is an opposing voltage generated by the rotor of a synchronous motor when it rotates. In synchronous motors, the back EMF plays a crucial role in maintaining the synchronization between the rotor and the stator magnetic fields. If the rotor speed changes, the back EMF also changes, which causes a corresponding change in the current flowing through the DC excitation field.

How to Calculate Back EMF of Synchronous Motor given Armature Winding Constant?

Back EMF of Synchronous Motor given Armature Winding Constant calculator uses Back EMF = Armature Winding Constant*Magnetic Flux*Synchronous Speed to calculate the Back EMF, The Back EMF of Synchronous Motor given Armature Winding Constant formula is defined as the opposite electromotive force induced into the synchronous motor. Back EMF is denoted by Eb symbol.

How to calculate Back EMF of Synchronous Motor given Armature Winding Constant using this online calculator? To use this online calculator for Back EMF of Synchronous Motor given Armature Winding Constant, enter Armature Winding Constant (Ka), Magnetic Flux (Φ) & Synchronous Speed (Ns) and hit the calculate button. Here is how the Back EMF of Synchronous Motor given Armature Winding Constant calculation can be explained with given input values -> 178.6058 = 0.61*0.12*2439.97029416382.

FAQ

What is Back EMF of Synchronous Motor given Armature Winding Constant?
The Back EMF of Synchronous Motor given Armature Winding Constant formula is defined as the opposite electromotive force induced into the synchronous motor and is represented as Eb = Ka*Φ*Ns or Back EMF = Armature Winding Constant*Magnetic Flux*Synchronous Speed. Armature Winding Constant is defined as the ratio of the voltage applied to the motor terminals to the speed of the motor under no-load conditions, Magnetic flux (Φ) is the number of magnetic field lines passing through the magnetic core of an electrical dc motor & Synchronous speed is a definite speed for an alternating-current machine that is dependent on the frequency of the supply circuit.
How to calculate Back EMF of Synchronous Motor given Armature Winding Constant?
The Back EMF of Synchronous Motor given Armature Winding Constant formula is defined as the opposite electromotive force induced into the synchronous motor is calculated using Back EMF = Armature Winding Constant*Magnetic Flux*Synchronous Speed. To calculate Back EMF of Synchronous Motor given Armature Winding Constant, you need Armature Winding Constant (Ka), Magnetic Flux (Φ) & Synchronous Speed (Ns). With our tool, you need to enter the respective value for Armature Winding Constant, Magnetic Flux & Synchronous Speed and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Back EMF?
In this formula, Back EMF uses Armature Winding Constant, Magnetic Flux & Synchronous Speed. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Back EMF = Mechanical Power/(Armature Current*cos(Load Angle-Phase Difference))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!