B Parameter in Nominal T Method Solution

STEP 0: Pre-Calculation Summary
Formula Used
B Parameter in T = Impedance in T*(1+(Impedance in T*Admittance in T/4))
Bt = Zt*(1+(Zt*Yt/4))
This formula uses 3 Variables
Variables Used
B Parameter in T - (Measured in Ohm) - B Parameter in T is a generalized line constant. also known as short circuit resistance in a transmission line.
Impedance in T - (Measured in Ohm) - Impedance in T is defined as the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit.
Admittance in T - (Measured in Siemens) - Admittance in T is the mathematical inverse of the impedance in a medium transmission line.
STEP 1: Convert Input(s) to Base Unit
Impedance in T: 9.07 Ohm --> 9.07 Ohm No Conversion Required
Admittance in T: 0.0221 Siemens --> 0.0221 Siemens No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Bt = Zt*(1+(Zt*Yt/4)) --> 9.07*(1+(9.07*0.0221/4))
Evaluating ... ...
Bt = 9.5245135725
STEP 3: Convert Result to Output's Unit
9.5245135725 Ohm --> No Conversion Required
FINAL ANSWER
9.5245135725 9.524514 Ohm <-- B Parameter in T
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Nominal T Method in Medium Line Calculators

Receiving End Angle using Sending End Power in Nominal T Method
​ LaTeX ​ Go Receiving End Phase Angle in T = acos((Sending End Power in T-Power Loss in T)/(Receiving End Voltage in T*Receiving End Current in T*3))
Sending End Current using Losses in Nominal T Method
​ LaTeX ​ Go Sending End Current in T = sqrt((Power Loss in T/(3/2)*Resistance in T)-(Receiving End Current in T^2))
Capacitive Voltage in Nominal T Method
​ LaTeX ​ Go Capacitive Voltage in T = Receiving End Voltage in T+(Receiving End Current in T*Impedance in T/2)
Losses in Nominal T Method
​ LaTeX ​ Go Power Loss in T = 3*(Resistance in T/2)*(Receiving End Current in T^2+Sending End Current in T^2)

B Parameter in Nominal T Method Formula

​LaTeX ​Go
B Parameter in T = Impedance in T*(1+(Impedance in T*Admittance in T/4))
Bt = Zt*(1+(Zt*Yt/4))

What is ABCD parameter?

The A, B, C, and D are the constants also known as the transmission parameters or chain parameters. These parameters are used for the analysis of an electrical network. It is also used for determining the performance of input, output voltage, and current of the transmission network.

How to Calculate B Parameter in Nominal T Method?

B Parameter in Nominal T Method calculator uses B Parameter in T = Impedance in T*(1+(Impedance in T*Admittance in T/4)) to calculate the B Parameter in T, The B Parameter in Nominal T method formula is defined as a generalized line constant. also known as short circuit resistance. It is used for determining the performance of input, output voltage, and current of the transmission network. B Parameter in T is denoted by Bt symbol.

How to calculate B Parameter in Nominal T Method using this online calculator? To use this online calculator for B Parameter in Nominal T Method, enter Impedance in T (Zt) & Admittance in T (Yt) and hit the calculate button. Here is how the B Parameter in Nominal T Method calculation can be explained with given input values -> 9.501891 = 9.07*(1+(9.07*0.0221/4)).

FAQ

What is B Parameter in Nominal T Method?
The B Parameter in Nominal T method formula is defined as a generalized line constant. also known as short circuit resistance. It is used for determining the performance of input, output voltage, and current of the transmission network and is represented as Bt = Zt*(1+(Zt*Yt/4)) or B Parameter in T = Impedance in T*(1+(Impedance in T*Admittance in T/4)). Impedance in T is defined as the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit & Admittance in T is the mathematical inverse of the impedance in a medium transmission line.
How to calculate B Parameter in Nominal T Method?
The B Parameter in Nominal T method formula is defined as a generalized line constant. also known as short circuit resistance. It is used for determining the performance of input, output voltage, and current of the transmission network is calculated using B Parameter in T = Impedance in T*(1+(Impedance in T*Admittance in T/4)). To calculate B Parameter in Nominal T Method, you need Impedance in T (Zt) & Admittance in T (Yt). With our tool, you need to enter the respective value for Impedance in T & Admittance in T and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!