Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD Solution

STEP 0: Pre-Calculation Summary
Formula Used
Average Output Current = Peak Input Voltage/(pi*Resistance)*(1+cos(Trigger Angle in Degree))
Iavg = Vi(max)/(pi*R)*(1+cos(αd))
This formula uses 1 Constants, 1 Functions, 4 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Average Output Current - (Measured in Ampere) - Average Output Current is defined as measure of the flow of electric charge in a circuit over a specified time period.
Peak Input Voltage - (Measured in Volt) - Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit.
Resistance - (Measured in Ohm) - Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
Trigger Angle in Degree - (Measured in Radian) - Trigger Angle in Degree it gives the firing angle of thyristor in degree.
STEP 1: Convert Input(s) to Base Unit
Peak Input Voltage: 22 Volt --> 22 Volt No Conversion Required
Resistance: 25 Ohm --> 25 Ohm No Conversion Required
Trigger Angle in Degree: 45 Degree --> 0.785398163397301 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Iavg = Vi(max)/(pi*R)*(1+cos(αd)) --> 22/(pi*25)*(1+cos(0.785398163397301))
Evaluating ... ...
Iavg = 0.478182289396328
STEP 3: Convert Result to Output's Unit
0.478182289396328 Ampere --> No Conversion Required
FINAL ANSWER
0.478182289396328 0.478182 Ampere <-- Average Output Current
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Pratik Kumar Singh
Vellore Institute of Technology (VIT), Vellore
Pratik Kumar Singh has created this Calculator and 10+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 500+ more calculators!

Full Wave Controlled Rectifiers Calculators

RMS Voltage of Full Wave Thyristor Rectifier with R Load
​ LaTeX ​ Go RMS Voltage in Full Wave = sqrt(((0.5*sin(2*Trigger Angle in Degree))+pi-Trigger Angle in Radians)*((Maximum Output Voltage^2)/(2*pi)))
Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD
​ LaTeX ​ Go Average Output Current = Peak Input Voltage/(pi*Resistance)*(1+cos(Trigger Angle in Degree))
Average Voltage of Full Wave Thyristor Rectifier with RL Load (CCM) without FWD
​ LaTeX ​ Go Average Output Voltage in Full Wave = (2*Maximum Output Voltage*cos(Trigger Angle in Degree))/pi
RMS Voltage of Full Wave Thyristor Rectifier with RL Load (CCM) without FWD
​ LaTeX ​ Go RMS Voltage in Full Wave = Maximum Output Voltage/sqrt(2)

Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD Formula

​LaTeX ​Go
Average Output Current = Peak Input Voltage/(pi*Resistance)*(1+cos(Trigger Angle in Degree))
Iavg = Vi(max)/(pi*R)*(1+cos(αd))

How does firing angle affect the Average Output Current in full-wave controlled rectifier?

Changing the firing angle in a full-wave controlled rectifier significantly affects the Average Output Current. As the firing angle increases, the conduction period of the thyristors decreases, resulting in a smaller portion of the AC input voltage being rectified and sent to the load. This leads to a lower average output current, causing a greater phase shift between the current and voltage waveforms. Conversely, decreasing the firing angle increases conduction time, leading to a higher average output current and reduced phase shift, resulting in a smoother and more continuous output current waveform.

How to Calculate Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD?

Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD calculator uses Average Output Current = Peak Input Voltage/(pi*Resistance)*(1+cos(Trigger Angle in Degree)) to calculate the Average Output Current, The Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD formula is defined as the mean value of the rectified output current over one complete AC cycle. The freewheeling diode ensures that the current remains continuous. Average Output Current is denoted by Iavg symbol.

How to calculate Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD using this online calculator? To use this online calculator for Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD, enter Peak Input Voltage (Vi(max)), Resistance (R) & Trigger Angle in Degree d) and hit the calculate button. Here is how the Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD calculation can be explained with given input values -> 0.478182 = 22/(pi*25)*(1+cos(0.785398163397301)).

FAQ

What is Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD?
The Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD formula is defined as the mean value of the rectified output current over one complete AC cycle. The freewheeling diode ensures that the current remains continuous and is represented as Iavg = Vi(max)/(pi*R)*(1+cos(αd)) or Average Output Current = Peak Input Voltage/(pi*Resistance)*(1+cos(Trigger Angle in Degree)). Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit, Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm & Trigger Angle in Degree it gives the firing angle of thyristor in degree.
How to calculate Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD?
The Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD formula is defined as the mean value of the rectified output current over one complete AC cycle. The freewheeling diode ensures that the current remains continuous is calculated using Average Output Current = Peak Input Voltage/(pi*Resistance)*(1+cos(Trigger Angle in Degree)). To calculate Average Output Current of Single Phase Full Wave Controlled Rectifier with R Load of FWD, you need Peak Input Voltage (Vi(max)), Resistance (R) & Trigger Angle in Degree d). With our tool, you need to enter the respective value for Peak Input Voltage, Resistance & Trigger Angle in Degree and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp