Average Flow = (Chlorine Required/(Dosage*Peaking Factor*8.34))
Qa = (Cl2/(D*f*8.34))
This formula uses 4 Variables
Variables Used
Average Flow - (Measured in Cubic Meter per Second) - Average Flow often refers to the average velocity of a fluid over a certain period of time or through a specific area.
Chlorine Required - (Measured in Kilogram per Second) - Chlorine Required means pounds of chlorine required per day.
Dosage - (Measured in Kilogram per Cubic Meter) - Dosage used to obtain coliform reduction refers to the amount of disinfectant added to the wastewater to achieve the desired level of pathogen reduction or disinfection efficacy.
Peaking Factor - Peaking Factor is the ratio of the maximum flow to the average daily flow in a water system.
STEP 1: Convert Input(s) to Base Unit
Chlorine Required: 10 Kilogram per Day --> 0.000115740740740741 Kilogram per Second (Check conversion ​here)
Dosage: 0.004626 Milligram per Liter --> 4.626E-06 Kilogram per Cubic Meter (Check conversion ​here)
Peaking Factor: 0.9999 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qa = (Cl2/(D*f*8.34)) --> (0.000115740740740741/(4.626E-06*0.9999*8.34))
Evaluating ... ...
Qa = 3.00025390769973
STEP 3: Convert Result to Output's Unit
3.00025390769973 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
3.00025390769973 3.000254 Cubic Meter per Second <-- Average Flow
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of a Chlorination System for Wastewater Disinfection Calculators

Residence Time given Number of Coliform Organisms at Any Particular Time
​ LaTeX ​ Go Residence Time = ((Number of Coliform/Number of Coliform at Initial Time)^(1/3)-1)/(0.23*Chlorine Residual)
Total Chlorine Residual at Any Particular Time
​ LaTeX ​ Go Chlorine Residual = ((Number of Coliform/Number of Coliform at Initial Time)^(1/3)-1)/(0.23*Residence Time)
Number of Coliform Organisms at any Initial Time
​ LaTeX ​ Go Number of Coliform = (Number of Coliform at Initial Time/(1+0.23*Chlorine Residual*Residence Time)^(-3))
Number of Coliform Organisms at Any Particular Time
​ LaTeX ​ Go Number of Coliform at Initial Time = Number of Coliform*(1+0.23*Chlorine Residual*Residence Time)^(-3)

Average Flow given Capacity of Chlorinator at Peak Flow Formula

​LaTeX ​Go
Average Flow = (Chlorine Required/(Dosage*Peaking Factor*8.34))
Qa = (Cl2/(D*f*8.34))

What is chlorinator ?

A chlorinator dispenses sanitizer (either chlorine or bromine) into the water in a controlled, gradual manner. Pool chlorinators use either tablets or sticks to sanitize your water and slowly disperse them into your pool.

How to Calculate Average Flow given Capacity of Chlorinator at Peak Flow?

Average Flow given Capacity of Chlorinator at Peak Flow calculator uses Average Flow = (Chlorine Required/(Dosage*Peaking Factor*8.34)) to calculate the Average Flow, The Average Flow given Capacity of Chlorinator at Peak Flow is defined as the average flow when we have prior information of other parameters. Average Flow is denoted by Qa symbol.

How to calculate Average Flow given Capacity of Chlorinator at Peak Flow using this online calculator? To use this online calculator for Average Flow given Capacity of Chlorinator at Peak Flow, enter Chlorine Required (Cl2), Dosage (D) & Peaking Factor (f) and hit the calculate button. Here is how the Average Flow given Capacity of Chlorinator at Peak Flow calculation can be explained with given input values -> 1.499977 = (0.000115740740740741/(4.626E-06*0.9999*8.34)).

FAQ

What is Average Flow given Capacity of Chlorinator at Peak Flow?
The Average Flow given Capacity of Chlorinator at Peak Flow is defined as the average flow when we have prior information of other parameters and is represented as Qa = (Cl2/(D*f*8.34)) or Average Flow = (Chlorine Required/(Dosage*Peaking Factor*8.34)). Chlorine Required means pounds of chlorine required per day, Dosage used to obtain coliform reduction refers to the amount of disinfectant added to the wastewater to achieve the desired level of pathogen reduction or disinfection efficacy & Peaking Factor is the ratio of the maximum flow to the average daily flow in a water system.
How to calculate Average Flow given Capacity of Chlorinator at Peak Flow?
The Average Flow given Capacity of Chlorinator at Peak Flow is defined as the average flow when we have prior information of other parameters is calculated using Average Flow = (Chlorine Required/(Dosage*Peaking Factor*8.34)). To calculate Average Flow given Capacity of Chlorinator at Peak Flow, you need Chlorine Required (Cl2), Dosage (D) & Peaking Factor (f). With our tool, you need to enter the respective value for Chlorine Required, Dosage & Peaking Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Average Flow?
In this formula, Average Flow uses Chlorine Required, Dosage & Peaking Factor. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Average Flow = (Chlorine Required/(Dosage*8.34))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!