Average Flow given Average Daily Consumption of Chlorine Solution

STEP 0: Pre-Calculation Summary
Formula Used
Average Flow = (Chlorine Required/(Dosage*8.34))
Qa = (Cl2/(D*8.34))
This formula uses 3 Variables
Variables Used
Average Flow - (Measured in Cubic Meter per Second) - Average Flow often refers to the average velocity of a fluid over a certain period of time or through a specific area.
Chlorine Required - (Measured in Kilogram per Second) - Chlorine Required means pounds of chlorine required per day.
Dosage - (Measured in Kilogram per Cubic Meter) - Dosage used to obtain coliform reduction refers to the amount of disinfectant added to the wastewater to achieve the desired level of pathogen reduction or disinfection efficacy.
STEP 1: Convert Input(s) to Base Unit
Chlorine Required: 10 Kilogram per Day --> 0.000115740740740741 Kilogram per Second (Check conversion ​here)
Dosage: 0.004626 Milligram per Liter --> 4.626E-06 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qa = (Cl2/(D*8.34)) --> (0.000115740740740741/(4.626E-06*8.34))
Evaluating ... ...
Qa = 2.99995388230896
STEP 3: Convert Result to Output's Unit
2.99995388230896 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
2.99995388230896 2.999954 Cubic Meter per Second <-- Average Flow
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of a Chlorination System for Wastewater Disinfection Calculators

Residence Time given Number of Coliform Organisms at Any Particular Time
​ LaTeX ​ Go Residence Time = ((Number of Coliform/Number of Coliform at Initial Time)^(1/3)-1)/(0.23*Chlorine Residual)
Total Chlorine Residual at Any Particular Time
​ LaTeX ​ Go Chlorine Residual = ((Number of Coliform/Number of Coliform at Initial Time)^(1/3)-1)/(0.23*Residence Time)
Number of Coliform Organisms at any Initial Time
​ LaTeX ​ Go Number of Coliform = (Number of Coliform at Initial Time/(1+0.23*Chlorine Residual*Residence Time)^(-3))
Number of Coliform Organisms at Any Particular Time
​ LaTeX ​ Go Number of Coliform at Initial Time = Number of Coliform*(1+0.23*Chlorine Residual*Residence Time)^(-3)

Average Flow given Average Daily Consumption of Chlorine Formula

​LaTeX ​Go
Average Flow = (Chlorine Required/(Dosage*8.34))
Qa = (Cl2/(D*8.34))

What is average flow time ?

The average of the flow times across all flow units that exit the process during a specific span of time. Flow Rate – The number of flow units that flow through a specific point in the process per unit of time. It is the reciprocal of average flow time.

How to Calculate Average Flow given Average Daily Consumption of Chlorine?

Average Flow given Average Daily Consumption of Chlorine calculator uses Average Flow = (Chlorine Required/(Dosage*8.34)) to calculate the Average Flow, The Average Flow given Average Daily Consumption of Chlorine is defined as the average flow when we have prior information of dosage and chlorine required. Average Flow is denoted by Qa symbol.

How to calculate Average Flow given Average Daily Consumption of Chlorine using this online calculator? To use this online calculator for Average Flow given Average Daily Consumption of Chlorine, enter Chlorine Required (Cl2) & Dosage (D) and hit the calculate button. Here is how the Average Flow given Average Daily Consumption of Chlorine calculation can be explained with given input values -> 2.999954 = (0.000115740740740741/(4.626E-06*8.34)).

FAQ

What is Average Flow given Average Daily Consumption of Chlorine?
The Average Flow given Average Daily Consumption of Chlorine is defined as the average flow when we have prior information of dosage and chlorine required and is represented as Qa = (Cl2/(D*8.34)) or Average Flow = (Chlorine Required/(Dosage*8.34)). Chlorine Required means pounds of chlorine required per day & Dosage used to obtain coliform reduction refers to the amount of disinfectant added to the wastewater to achieve the desired level of pathogen reduction or disinfection efficacy.
How to calculate Average Flow given Average Daily Consumption of Chlorine?
The Average Flow given Average Daily Consumption of Chlorine is defined as the average flow when we have prior information of dosage and chlorine required is calculated using Average Flow = (Chlorine Required/(Dosage*8.34)). To calculate Average Flow given Average Daily Consumption of Chlorine, you need Chlorine Required (Cl2) & Dosage (D). With our tool, you need to enter the respective value for Chlorine Required & Dosage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Average Flow?
In this formula, Average Flow uses Chlorine Required & Dosage. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Average Flow = (Chlorine Required/(Dosage*Peaking Factor*8.34))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!