How to Calculate Average Field Voltage of Three Phase Semi-Converter Drive?
Average Field Voltage of Three Phase Semi-Converter Drive calculator uses Semi Drive Field Voltage in Three Phase = (3*Peak Input Voltage*(1+cos(Delay Angle of Thyristor)))/(2*pi) to calculate the Semi Drive Field Voltage in Three Phase, The Average Field Voltage of Three Phase Semi-Converter Drive formula is the average voltage developed at the terminals of the armature of the DC motor drive. in the above formula, the delay angle of the field thyristor (αf) is considered. Semi Drive Field Voltage in Three Phase is denoted by Vf(semi_3p) symbol.
How to calculate Average Field Voltage of Three Phase Semi-Converter Drive using this online calculator? To use this online calculator for Average Field Voltage of Three Phase Semi-Converter Drive, enter Peak Input Voltage (Vm) & Delay Angle of Thyristor (α) and hit the calculate button. Here is how the Average Field Voltage of Three Phase Semi-Converter Drive calculation can be explained with given input values -> 140.9688 = (3*220*(1+cos(1.2217304763958)))/(2*pi).