Area of X-section using Volume of Conductor Material(DC Three-Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC)
A = V/(2.5*l)
This formula uses 3 Variables
Variables Used
Area of underground dc wire - (Measured in Square Meter) - The Area of underground dc wire is the amount of two-dimensional space taken up by an object.
Volume Of Conductor - (Measured in Cubic Meter) - Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the measurement or extent of something from end to end.
STEP 1: Convert Input(s) to Base Unit
Volume Of Conductor: 35 Cubic Meter --> 35 Cubic Meter No Conversion Required
Length of Wire DC: 3.2 Meter --> 3.2 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
A = V/(2.5*l) --> 35/(2.5*3.2)
Evaluating ... ...
A = 4.375
STEP 3: Convert Result to Output's Unit
4.375 Square Meter --> No Conversion Required
FINAL ANSWER
4.375 Square Meter <-- Area of underground dc wire
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Length using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Length of Wire DC = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/((5)*Resistivity*(Power Transmitted^2)))
Line Losses using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Line Losses = 5*Resistivity*((Power Transmitted*Length of Wire DC)^2)/(Volume Of Conductor*(Maximum Voltage^2))
Area of X-section using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC)
Constant using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Constant underground dc = Volume Of Conductor/(1.25)

Area of X-section using Volume of Conductor Material(DC Three-Wire US) Formula

​LaTeX ​Go
Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC)
A = V/(2.5*l)

What is a 3 wire dc system?

This is basically a combination of two series-connected unipolar DC systems. It consists of three conductors, two outer conductors (one is positive and the other is negative), and one middle conductor which acts as neutral.

How to Calculate Area of X-section using Volume of Conductor Material(DC Three-Wire US)?

Area of X-section using Volume of Conductor Material(DC Three-Wire US) calculator uses Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC) to calculate the Area of underground dc wire, The Area of X-section using Volume of Conductor Material(DC Three-Wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of underground dc wire is denoted by A symbol.

How to calculate Area of X-section using Volume of Conductor Material(DC Three-Wire US) using this online calculator? To use this online calculator for Area of X-section using Volume of Conductor Material(DC Three-Wire US), enter Volume Of Conductor (V) & Length of Wire DC (l) and hit the calculate button. Here is how the Area of X-section using Volume of Conductor Material(DC Three-Wire US) calculation can be explained with given input values -> 4.375 = 35/(2.5*3.2).

FAQ

What is Area of X-section using Volume of Conductor Material(DC Three-Wire US)?
The Area of X-section using Volume of Conductor Material(DC Three-Wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier and is represented as A = V/(2.5*l) or Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC). Volume Of Conductor the 3-dimensional space enclosed by a conductor material & Length of Wire DC is the measurement or extent of something from end to end.
How to calculate Area of X-section using Volume of Conductor Material(DC Three-Wire US)?
The Area of X-section using Volume of Conductor Material(DC Three-Wire US) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier is calculated using Area of underground dc wire = Volume Of Conductor/(2.5*Length of Wire DC). To calculate Area of X-section using Volume of Conductor Material(DC Three-Wire US), you need Volume Of Conductor (V) & Length of Wire DC (l). With our tool, you need to enter the respective value for Volume Of Conductor & Length of Wire DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Area of underground dc wire?
In this formula, Area of underground dc wire uses Volume Of Conductor & Length of Wire DC. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Area of underground dc wire = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*(Maximum Voltage^2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!