How to Calculate Area of X-Section using Line Losses (2-Phase 4-Wire OS)?
Area of X-Section using Line Losses (2-Phase 4-Wire OS) calculator uses Area of Overhead AC Wire = Resistivity*Length of Overhead AC Wire*(Power Transmitted)^2/(2*Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2) to calculate the Area of Overhead AC Wire, The Area of X-Section using Line Losses (2-Phase 4-Wire OS) formula is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” This makes number handling ever so much easier. Area of Overhead AC Wire is denoted by A symbol.
How to calculate Area of X-Section using Line Losses (2-Phase 4-Wire OS) using this online calculator? To use this online calculator for Area of X-Section using Line Losses (2-Phase 4-Wire OS), enter Resistivity (ρ), Length of Overhead AC Wire (L), Power Transmitted (P), Line Losses (Ploss), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) and hit the calculate button. Here is how the Area of X-Section using Line Losses (2-Phase 4-Wire OS) calculation can be explained with given input values -> 0.003016 = 1.7E-05*10.63*(890)^2/(2*8.23*(62*cos(0.5235987755982))^2).