Area of Tank given Height at Outlet Zone with respect to Area of Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area = Discharge*Outer Height/(Height of Crack*Falling Speed)
A = Q*H/(h*v')
This formula uses 5 Variables
Variables Used
Area - (Measured in Square Meter) - The Area of a sedimentation tank refers to the surface area of the tank where sedimentation, or the settling of suspended particles, occurs.
Discharge - (Measured in Cubic Meter per Second) - The Discharge refers to the volume of water that flows through a given cross-sectional area of the tank, per unit of time.
Outer Height - (Measured in Meter) - The Outer Height refers to the external vertical dimension of an object or structure.
Height of Crack - (Measured in Meter) - The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Falling Speed - (Measured in Meter per Second) - The Falling Speed refers to the constant speed at which a particle falls through a fluid when the force of gravity is balanced by the drag force and buoyant force acting on the particle.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.5 Cubic Meter per Second --> 1.5 Cubic Meter per Second No Conversion Required
Outer Height: 40 Meter --> 40 Meter No Conversion Required
Height of Crack: 12000 Millimeter --> 12 Meter (Check conversion ​here)
Falling Speed: 0.1 Meter per Second --> 0.1 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
A = Q*H/(h*v') --> 1.5*40/(12*0.1)
Evaluating ... ...
A = 50
STEP 3: Convert Result to Output's Unit
50 Square Meter --> No Conversion Required
FINAL ANSWER
50 Square Meter <-- Area
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Area of Sedimentation Tank Calculators

Area of Tank given Height at Outlet Zone with respect to Area of Tank
​ LaTeX ​ Go Area = Discharge*Outer Height/(Height of Crack*Falling Speed)
Cross-Sectional Area given Surface Area with respect to Darcy Weishbach Friction Factor
​ LaTeX ​ Go Cross-Sectional Area = Area*sqrt(Darcy Friction Factor/8)
Area of Tank given Vertical Falling Speed in Sedimentation Tank with respect to Area
​ LaTeX ​ Go Area = Environmental Discharge/Settling Velocity
Cross-Sectional Area of Sedimentation Tank
​ LaTeX ​ Go Area = Width*Height of Crack

Area of Tank given Height at Outlet Zone with respect to Area of Tank Formula

​LaTeX ​Go
Area = Discharge*Outer Height/(Height of Crack*Falling Speed)
A = Q*H/(h*v')

What is Sedimentation?

Sedimentation is the tendency for particles in suspension to settle out of the fluid in which they are entrained and come to rest against a barrier. This is due to their motion through the fluid in response to the forces acting on them: these forces can be due to gravity, centrifugal acceleration, or electromagnetism.

How to Calculate Area of Tank given Height at Outlet Zone with respect to Area of Tank?

Area of Tank given Height at Outlet Zone with respect to Area of Tank calculator uses Area = Discharge*Outer Height/(Height of Crack*Falling Speed) to calculate the Area, The Area of Tank given Height at Outlet Zone with respect to Area of Tank formula is defined as the measure of total area that surface of object occupies. Area is denoted by A symbol.

How to calculate Area of Tank given Height at Outlet Zone with respect to Area of Tank using this online calculator? To use this online calculator for Area of Tank given Height at Outlet Zone with respect to Area of Tank, enter Discharge (Q), Outer Height (H), Height of Crack (h) & Falling Speed (v') and hit the calculate button. Here is how the Area of Tank given Height at Outlet Zone with respect to Area of Tank calculation can be explained with given input values -> 33.66667 = 1.5*40/(12*0.1).

FAQ

What is Area of Tank given Height at Outlet Zone with respect to Area of Tank?
The Area of Tank given Height at Outlet Zone with respect to Area of Tank formula is defined as the measure of total area that surface of object occupies and is represented as A = Q*H/(h*v') or Area = Discharge*Outer Height/(Height of Crack*Falling Speed). The Discharge refers to the volume of water that flows through a given cross-sectional area of the tank, per unit of time, The Outer Height refers to the external vertical dimension of an object or structure, The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress & The Falling Speed refers to the constant speed at which a particle falls through a fluid when the force of gravity is balanced by the drag force and buoyant force acting on the particle.
How to calculate Area of Tank given Height at Outlet Zone with respect to Area of Tank?
The Area of Tank given Height at Outlet Zone with respect to Area of Tank formula is defined as the measure of total area that surface of object occupies is calculated using Area = Discharge*Outer Height/(Height of Crack*Falling Speed). To calculate Area of Tank given Height at Outlet Zone with respect to Area of Tank, you need Discharge (Q), Outer Height (H), Height of Crack (h) & Falling Speed (v'). With our tool, you need to enter the respective value for Discharge, Outer Height, Height of Crack & Falling Speed and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Area?
In this formula, Area uses Discharge, Outer Height, Height of Crack & Falling Speed. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Area = Environmental Discharge/Settling Velocity
  • Area = Width*Height of Crack
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!