Area of Prestressing Tendon for Known Tensile Strength of Section Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area of Prestressing Steel = Tensile Force/(0.87*Tensile Strength of Prestressed Steel)
As = PuR/(0.87*Fpkf)
This formula uses 3 Variables
Variables Used
Area of Prestressing Steel - (Measured in Square Meter) - Area of Prestressing Steel is the total cross sectional area of tendons.
Tensile Force - (Measured in Newton) - Tensile Force is the stretching force acted on the section having prestressed tendons within it.
Tensile Strength of Prestressed Steel - (Measured in Pascal) - Tensile Strength of Prestressed Steel is the tensile capacity of the prestressed tendons.
STEP 1: Convert Input(s) to Base Unit
Tensile Force: 4.35 Kilonewton --> 4350 Newton (Check conversion ​here)
Tensile Strength of Prestressed Steel: 249 Megapascal --> 249000000 Pascal (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
As = PuR/(0.87*Fpkf) --> 4350/(0.87*249000000)
Evaluating ... ...
As = 2.00803212851406E-05
STEP 3: Convert Result to Output's Unit
2.00803212851406E-05 Square Meter -->20.0803212851406 Square Millimeter (Check conversion ​here)
FINAL ANSWER
20.0803212851406 20.08032 Square Millimeter <-- Area of Prestressing Steel
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 700+ more calculators!

Analysis of Ultimate Strength Calculators

Ultimate Tensile Strength of Section in Presence of Non-Prestressing Reinforcement
​ LaTeX ​ Go Tensile Force = 0.87*Tensile Strength of Prestressed Steel*Area of Prestressing Steel+(0.87*Yield Strength of Steel*Area of Reinforcement)
Characteristic Tensile Strength of Prestressing Tendons for Known Tensile Strength of Section
​ LaTeX ​ Go Tensile Strength of Prestressed Steel = Tensile Force/(0.87*Area of Prestressing Steel)
Area of Prestressing Tendon for Known Tensile Strength of Section
​ LaTeX ​ Go Area of Prestressing Steel = Tensile Force/(0.87*Tensile Strength of Prestressed Steel)
Ultimate Tensile Force in Absence of Non-Prestressed Reinforcement
​ LaTeX ​ Go Tensile Force = 0.87*Tensile Strength of Prestressed Steel*Area of Prestressing Steel

Area of Prestressing Tendon for Known Tensile Strength of Section Formula

​LaTeX ​Go
Area of Prestressing Steel = Tensile Force/(0.87*Tensile Strength of Prestressed Steel)
As = PuR/(0.87*Fpkf)

What are the characteristic features of Prestressing Steel?

For prestressed concrete, high strength steel is used to provide high elongation to maintain the steel stress after the prestress loss.
Ideally, it should also:
• Remain elastic up to relatively high stress.
• Show sufficient ductility before failure.
• Have good bonding properties, low relaxation, good resistance to corrosion.
• Be economical and easy to handle

How to Calculate Area of Prestressing Tendon for Known Tensile Strength of Section?

Area of Prestressing Tendon for Known Tensile Strength of Section calculator uses Area of Prestressing Steel = Tensile Force/(0.87*Tensile Strength of Prestressed Steel) to calculate the Area of Prestressing Steel, The Area of Prestressing Tendon for Known Tensile Strength of Section is defines as the area of prestressing tendon used in the prestressed section without non-prestressing reinforcement. Area of Prestressing Steel is denoted by As symbol.

How to calculate Area of Prestressing Tendon for Known Tensile Strength of Section using this online calculator? To use this online calculator for Area of Prestressing Tendon for Known Tensile Strength of Section, enter Tensile Force (PuR) & Tensile Strength of Prestressed Steel (Fpkf) and hit the calculate button. Here is how the Area of Prestressing Tendon for Known Tensile Strength of Section calculation can be explained with given input values -> 2E+7 = 4350/(0.87*249000000).

FAQ

What is Area of Prestressing Tendon for Known Tensile Strength of Section?
The Area of Prestressing Tendon for Known Tensile Strength of Section is defines as the area of prestressing tendon used in the prestressed section without non-prestressing reinforcement and is represented as As = PuR/(0.87*Fpkf) or Area of Prestressing Steel = Tensile Force/(0.87*Tensile Strength of Prestressed Steel). Tensile Force is the stretching force acted on the section having prestressed tendons within it & Tensile Strength of Prestressed Steel is the tensile capacity of the prestressed tendons.
How to calculate Area of Prestressing Tendon for Known Tensile Strength of Section?
The Area of Prestressing Tendon for Known Tensile Strength of Section is defines as the area of prestressing tendon used in the prestressed section without non-prestressing reinforcement is calculated using Area of Prestressing Steel = Tensile Force/(0.87*Tensile Strength of Prestressed Steel). To calculate Area of Prestressing Tendon for Known Tensile Strength of Section, you need Tensile Force (PuR) & Tensile Strength of Prestressed Steel (Fpkf). With our tool, you need to enter the respective value for Tensile Force & Tensile Strength of Prestressed Steel and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!