Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area of Opening = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2))
Ao = Qi/(0.6*(2*g*D)^(1/2))
This formula uses 4 Variables
Variables Used
Area of Opening - (Measured in Square Meter) - The Area of Opening refers to the physical space in a structure or barrier through which air, water, or other substances can pass.
Inlet Capacity - (Measured in Cubic Meter per Second) - The Inlet Capacity refers to the maximum rate at which a storm water inlet or drainage structure can accept and convey water without causing flooding or other adverse impacts.
Acceleration due to Gravity - (Measured in Meter per Square Second) - Acceleration due to Gravity is acceleration gained by an object because of gravitational force.
Depth - (Measured in Meter) - The Depth refers to the vertical distance from a reference point to the bottom of a body of water or to a specific depth below the water surface.
STEP 1: Convert Input(s) to Base Unit
Inlet Capacity: 42 Cubic Meter per Second --> 42 Cubic Meter per Second No Conversion Required
Acceleration due to Gravity: 9.8 Meter per Square Second --> 9.8 Meter per Square Second No Conversion Required
Depth: 3 Meter --> 3 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ao = Qi/(0.6*(2*g*D)^(1/2)) --> 42/(0.6*(2*9.8*3)^(1/2))
Evaluating ... ...
Ao = 9.12870929175277
STEP 3: Convert Result to Output's Unit
9.12870929175277 Square Meter --> No Conversion Required
FINAL ANSWER
9.12870929175277 9.128709 Square Meter <-- Area of Opening
(Calculation completed in 00.008 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Disposing of Storm Water Calculators

Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
​ LaTeX ​ Go Depression in Curb Inlet = ((Runoff Quantity/(0.7*Length of Opening))^(2/3))-Depth of Flow at Inlet
Depth of Flow at Inlet given Runoff Quantity with Full Gutter Flow
​ LaTeX ​ Go Depth of Flow at Inlet = ((Runoff Quantity/(0.7*Length of Opening))^(2/3))-Depression in Curb Inlet
Length of Opening given Runoff Quantity with Full Gutter Flow
​ LaTeX ​ Go Length of Opening = Runoff Quantity/(0.7*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2))
Runoff Quantity with Full Gutter Flow
​ LaTeX ​ Go Runoff Quantity = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2)

Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in Formula

​LaTeX ​Go
Area of Opening = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2))
Ao = Qi/(0.6*(2*g*D)^(1/2))

What is Flow Depth?

Flow depth is the depth of flow in a channel or culvert when the slope of the water surface and channel bottom is the same and the water depth remains constant.

How to Calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in?

Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in calculator uses Area of Opening = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2)) to calculate the Area of Opening, The Area of opening given inlet capacity for flow depth more than 1ft 5in is defined as is area of opening of sewer pipe from where waste is discharged. Area of Opening is denoted by Ao symbol.

How to calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in using this online calculator? To use this online calculator for Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in, enter Inlet Capacity (Qi), Acceleration due to Gravity (g) & Depth (D) and hit the calculate button. Here is how the Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in calculation can be explained with given input values -> 9.128709 = 42/(0.6*(2*9.8*3)^(1/2)).

FAQ

What is Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in?
The Area of opening given inlet capacity for flow depth more than 1ft 5in is defined as is area of opening of sewer pipe from where waste is discharged and is represented as Ao = Qi/(0.6*(2*g*D)^(1/2)) or Area of Opening = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2)). The Inlet Capacity refers to the maximum rate at which a storm water inlet or drainage structure can accept and convey water without causing flooding or other adverse impacts, Acceleration due to Gravity is acceleration gained by an object because of gravitational force & The Depth refers to the vertical distance from a reference point to the bottom of a body of water or to a specific depth below the water surface.
How to calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in?
The Area of opening given inlet capacity for flow depth more than 1ft 5in is defined as is area of opening of sewer pipe from where waste is discharged is calculated using Area of Opening = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2)). To calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in, you need Inlet Capacity (Qi), Acceleration due to Gravity (g) & Depth (D). With our tool, you need to enter the respective value for Inlet Capacity, Acceleration due to Gravity & Depth and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!