Area of Mouthpiece in Borda's Mouthpiece Running Full Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area = Discharge through Mouthpiece/(0.707*sqrt(2*9.81*Constant Head))
A = QM/(0.707*sqrt(2*9.81*Hc))
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Area - (Measured in Square Meter) - The area is the amount of two-dimensional space taken up by an object.
Discharge through Mouthpiece - (Measured in Cubic Meter per Second) - The Discharge through mouthpiece is considered in the flow without sudden enlargement.
Constant Head - (Measured in Meter) - The Constant head is considered for discharging of the water from an mouthpiece.
STEP 1: Convert Input(s) to Base Unit
Discharge through Mouthpiece: 30.2 Cubic Meter per Second --> 30.2 Cubic Meter per Second No Conversion Required
Constant Head: 10.5 Meter --> 10.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
A = QM/(0.707*sqrt(2*9.81*Hc)) --> 30.2/(0.707*sqrt(2*9.81*10.5))
Evaluating ... ...
A = 2.97607161784103
STEP 3: Convert Result to Output's Unit
2.97607161784103 Square Meter --> No Conversion Required
FINAL ANSWER
2.97607161784103 2.976072 Square Meter <-- Area
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Maiarutselvan V
PSG College of Technology (PSGCT), Coimbatore
Maiarutselvan V has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Sanjay Krishna
Amrita School of Engineering (ASE), Vallikavu
Sanjay Krishna has verified this Calculator and 200+ more calculators!

Geometric Dimensions Calculators

Area of Orifice given Time of Emptying Hemispherical Tank
​ LaTeX ​ Go Area of Orifice = (pi*(((4/3)*Hemispherical Tank Radius*((Initial Height of Liquid^(3/2))-(Final Height of Liquid^(3/2))))-((2/5)*((Initial Height of Liquid^(5/2))-(Final Height of Liquid)^(5/2)))))/(Total Time Taken*Coefficient of Discharge*(sqrt(2*9.81)))
Area of Tank given Time for Emptying Tank
​ LaTeX ​ Go Area of Tank = (Total Time Taken*Coefficient of Discharge*Area of Orifice*(sqrt(2*9.81)))/(2*((sqrt(Initial Height of Liquid))-(sqrt(Final Height of Liquid))))
Vertical distance for coefficient of velocity and horizontal distance
​ LaTeX ​ Go Vertical Distance = (Horizontal Distance^2)/(4*(Coefficient of Velocity^2)*Head of the Liquid)
Area at vena contracta for discharge and constant head
​ LaTeX ​ Go Area at Vena Contracta = Discharge through Mouthpiece/(sqrt(2*9.81*Constant Head))

Area of Mouthpiece in Borda's Mouthpiece Running Full Formula

​LaTeX ​Go
Area = Discharge through Mouthpiece/(0.707*sqrt(2*9.81*Constant Head))
A = QM/(0.707*sqrt(2*9.81*Hc))

What is internal mouthpiece?

A short cylindrical tube is attached to an orifice in such a way that the tube projects inwardly to a tank, which is called an internal mouthpiece or Re-entrant or Borda's mouthpiece.

What is mouthpiece?

A mouthpiece is a short tube of length not more than two to three times its diameter, which is. fitted to a tank for measuring the discharge of the flow from the tank. By fitting the mouthpiece, the. discharge through an orifice of the tank can be increased.

How to Calculate Area of Mouthpiece in Borda's Mouthpiece Running Full?

Area of Mouthpiece in Borda's Mouthpiece Running Full calculator uses Area = Discharge through Mouthpiece/(0.707*sqrt(2*9.81*Constant Head)) to calculate the Area, The Area of Mouthpiece in Borda's Mouthpiece Running Full is considered on flow-through internal or re-entrant on Borda's mouthpiece where the length of the tube is three times its diameter, then the jet comes out with its diameter equal to the diameter of a mouthpiece at the outlet. Area is denoted by A symbol.

How to calculate Area of Mouthpiece in Borda's Mouthpiece Running Full using this online calculator? To use this online calculator for Area of Mouthpiece in Borda's Mouthpiece Running Full, enter Discharge through Mouthpiece (QM) & Constant Head (Hc) and hit the calculate button. Here is how the Area of Mouthpiece in Borda's Mouthpiece Running Full calculation can be explained with given input values -> 1.005163 = 30.2/(0.707*sqrt(2*9.81*10.5)).

FAQ

What is Area of Mouthpiece in Borda's Mouthpiece Running Full?
The Area of Mouthpiece in Borda's Mouthpiece Running Full is considered on flow-through internal or re-entrant on Borda's mouthpiece where the length of the tube is three times its diameter, then the jet comes out with its diameter equal to the diameter of a mouthpiece at the outlet and is represented as A = QM/(0.707*sqrt(2*9.81*Hc)) or Area = Discharge through Mouthpiece/(0.707*sqrt(2*9.81*Constant Head)). The Discharge through mouthpiece is considered in the flow without sudden enlargement & The Constant head is considered for discharging of the water from an mouthpiece.
How to calculate Area of Mouthpiece in Borda's Mouthpiece Running Full?
The Area of Mouthpiece in Borda's Mouthpiece Running Full is considered on flow-through internal or re-entrant on Borda's mouthpiece where the length of the tube is three times its diameter, then the jet comes out with its diameter equal to the diameter of a mouthpiece at the outlet is calculated using Area = Discharge through Mouthpiece/(0.707*sqrt(2*9.81*Constant Head)). To calculate Area of Mouthpiece in Borda's Mouthpiece Running Full, you need Discharge through Mouthpiece (QM) & Constant Head (Hc). With our tool, you need to enter the respective value for Discharge through Mouthpiece & Constant Head and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Area?
In this formula, Area uses Discharge through Mouthpiece & Constant Head. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Area = Discharge through Mouthpiece/(0.5*sqrt(2*9.81*Constant Head))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!